BrookVent AIRSTREAM XE+ Mounting instructions

Intermittent Extract
Ventilation
Installation, maintenance & user manual
Applicable for the following AIRSTREAM XE+ models:
PRODUCT CODE DESCRIPTION
AF 90-XEP-100 airstream Xe+ 100
AF 90-XEP-100T airstream Xe+ 100 T
AF 90-XEP-100HT airstream Xe+ 100 HT
AF 90-XEP-150 airstream Xe+ 150
AF 90-XEP-150T airstream Xe+ 150 T
AF 90-XEP-150HT airstream Xe+ 150 HT

2/14 brookvent.co.uk
airstream Xe+
Airstream Xe+ is an axial fan designed to ensure air extraction in small/medium-sized rooms such as
bathrooms, toilets, and kitchens.
The unit can be installed on walls, ceilings or windows and is suitable for air discharge directly to the
outside or using a short extract duct (less than 1.5m).
Table of contents
1. WARNINGS AND PRECAUTIONS.................................................................................................................... 3
1.1. Transport and storage ................................................................................................................................... 3
1.2. Installation ....................................................................................................................................................... 3
1.3. Use .................................................................................................................................................................... 3
1.4. Maintenance.................................................................................................................................................... 3
2. PRODUCT INFORMATION .............................................................................................................................. 4
2.1. General information ....................................................................................................................................... 4
2.2. Technical specification ................................................................................................................................... 4
2.3. Versions............................................................................................................................................................ 4
2.4. Dimensions [mm] and Weight [kg]............................................................................................................... 5
2.5. TRANSPORT AND STORAGE........................................................................................................................... 6
3. INSTALLATION ................................................................................................................................................. 6
3.1. Unpacking ........................................................................................................................................................ 6
3.2. Where to install ............................................................................................................................................... 6
3.3. Mounting and electrical wiring ..................................................................................................................... 7
4. MAINTENANCE .............................................................................................................................................. 11
5. DISPOSAL AND RECYCLING ......................................................................................................................... 12
6. ErP DIRECTIVE 1253/2014 ............................................................................................................................ 13
7. CUSTOMER SUPPORT................................................................................................................................... 14

3/14 brookvent.co.uk
1. WARNINGS AND PRECAUTIONS
WARNING
Read this manual carefully before using the product and keep it in a safe place for reference. This product has been
constructed up to a required standard and in compliance with regulations relating to electrical equipment and must be
installed by technically qualified personnel. The manufacturer assumes no responsibility for damage to persons or
property resulting from failure to observe the regulations contained in this booklet.
1.1. Transport and storage
-Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.).
1.2. Installation
-After removing the product from its packaging, verify its conditions. Do not leave the packaging within
reach of children or people with disabilities.
-The device should not be used as an activator for water heaters, stoves, etc., nor should it discharge
into hot air/fume vent ducts deriving from any type of combustion unit or tumble dryer.
-If the environment in which the product is installed also houses a fuel-operating device (water heater,
methane stove etc.) that is not a “sealed chamber” type, it is essential to ensure adequate air intake, to
ensure good combustion and proper equipment operation.
-If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid creating a hazard.
-The electrical system to which the device is connected must comply with local regulations.
-Before connecting the product to the power supply or the power outlet, ensure that:
•the data plate (voltage and frequency) corresponds to those of the electrical mains.
•the electrical power supply/socket is adequate for maximum device power.
-An omni polar switch should be incorporated in the fixed wiring, in accordance with the wiring rules, to
provide a full disconnection under overvoltage category III conditions (contact opening distance equal
to or greater than 3mm).
-Ensure adequate air infiltration into the room in compliance with existing regulations in order to ensure
proper device operation.
-Install the product so that the impeller is not accessible from the air outlet side as verified by contact
with the Test (test probe “B” of the norm EN61032) in compliance with the current safety regulations.
1.3. Use
-The device should not be used for applications other than those specified in this manual.
-This appliance can be used by children aged 8 years old and above and persons with reduced physical,
sensory or mental capabilities or lack of experience and knowledge if they have been given supervision
or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance.
-If any abnormalities in operation are detected, disconnect the device from the mains supply and contact
a qualified technician immediately. Use original spare parts only for repairs.
-
-Cleaning and user maintenance shall not be made by children without supervision.
-Do not touch the appliance with wet or damp hands/feet.
-The device is designed to intake clean air only, i.e. without grease, soot, chemical or corrosive agents, or
flammable or explosive mixtures.
-Do not use the product in the presence of inflammable vapors, such as alcohol, insecticides, gasoline,
etc.
-Do not obstruct ducts or grilles to ensure optimum air passage.
-Do not immerse the device or its parts in water or other liquids.
-Operating temperature: 0°C up to +50°C.
1.4. Maintenance
-Even if the mains supply to the unit has been disconnected there remains a risk of injury due to rotating
parts that have not come to a complete standstill.
-Turn off the main switch whenever a malfunction is detected or when cleaning.
-Use original spare parts only for repairs.

4/14 brookvent.co.uk
2. PRODUCT INFORMATION
2.1. General information
Airstream Xe+ is an axial fan designed to ensure air extraction in small/medium-sized rooms such
as bathrooms, toilets, and kitchens.
The unit can be installed on walls, ceilings or windows and is suitable for air discharge directly to
the outside or using a short extract duct (less than 1.5m).
2.2. Technical specification
•Material: high quality, impact, and UV-resistant ABS. Colour RAL 9010.
•Design front cover removable for cleaning without the use of tools.
•Rear reinforcement ring to prevent spigot deformation during installation.
•High efficiency aerodynamic fan with “winglet” blades to optimize acoustics and efficiency.
•Single phase induction motor with integrated thermal protection.
•Motor mounted on high quality sleeve bearings.
•The fan is double insulated: no earth connection is required.
•Suitable for continuous or intermittent operation.
•IPX4 degree of protection.
•Power supply 220V to 240V~ 50/60Hz.
2.3. Versions
STANDARD
The fan is operated using a separate ON/OFF switch or via a light switch (fig. 13A).
WITH TIMER (over-run)
The fan is provided with a timer circuit which is adjustable within a range from 1 minute to 25
minutes via a dedicated trimmer (fig. 14B).
Operation: the unit should be connected according to the diagram in fig. 13B, after the light is
switched on, the fan activates with a delay of max 1.5 seconds. After the light is switched off, the
fan continues to function for a pre-set period.
WITH HUMIDISTAT & TIMER
The fan is equipped with a humidity detector and a timer. The humidity detector operating
threshold is adjustable from 50% to 95% Relative Humidity. The timer is adjustable from aprox.
1 minute to 25 minutes via a corresponding trimmer (fig. 14C).
Turn the humidity detector trimmer completely clockwise and the humidistat function is
deactivated.
Automatic humidistat operation: Connected according to the diagram in fig. 13C. When the
percentage of Relative Humidity exceeds the pre-set threshold, the fan starts up automatically.
When the percentage of Relative Humidity goes below the threshold; the fan continues to
function for a pre-set period of time.

5/14 brookvent.co.uk
Operation with switch connection:+
connected according to the diagram in fig. 13C. After the light is switched on, the fan activates
with a delay of approx. 1.5 seconds. After it is switched off, the fan continues to function for a
pre-set period.
Attention: When the relative humidity level is higher than the pre-set threshold, automatic
operation with a humidistat has priority over manual operation, meaning that the fan cannot be
stopped with a switch.
2.4. Dimensions [mm] and Weight [kg]

6/14 brookvent.co.uk
2.5. TRANSPORT AND STORAGE
WARNING
Make sure that specific warnings in Chapter 2
are carefully read, understood, and applied!
The unit is delivered in one cardboard box.
The unit should be stored and transported in such a way that it is protected against physical
damage.
It should be covered so that dust, rain, and snow cannot enter and damage the unit and its
components.
3. INSTALLATION
WARNING
Make sure that specific warnings and cautions in Chapter 2
are carefully read, understood, and applied!
This section describes how to install the unit correctly.
The unit must be installed according to these instructions.
3.1. Unpacking
Verify that the unit (and accessories) delivered is according to order before starting the
installation.
Any discrepancies from the ordered equipment must be reported to the supplier.
3.2. Where to install

7/14 brookvent.co.uk
3.3. Mounting and electrical wiring

8/14 brookvent.co.uk

9/14 brookvent.co.uk

10/14 brookvent.co.uk

11/14 brookvent.co.uk
4. MAINTENANCE

12/14 brookvent.co.uk
5. DISPOSAL AND RECYCLING

13/14 brookvent.co.uk
6. ErP DIRECTIVE 1253/2014
a)
Mark
-
Brookvent
b)
Model
-
airstream Xe 100
airstream Xe 100 T
airstream Xe 100 HT
airstream Xe 150
airstream Xe 150 T
airstream Xe 150 HT
c)
SEC class
-
E
C
E
C
c1)
SEC warm climates
kWh/m2.a
-2,9
-9,6
-3
-9,7
c2)
SEC average climates
kWh/m2.a
-10,5
-24
-10,7
-24,1
c3)
SEC cold climated
kWh/m2.a
-23,9
-49,1
-24
-49,2
Energy label
-
No
d)
Unit typology
-
Residential - unidirectional
e)
Type of drive
-
Single speed drive
f)
Type of Heat Recovery System
-
Absent
g)
Thernal efficiency of heat
recovery
%
N/A
h)
Maximum flow rate
m3/h
83
83
253
253
i)
Electric power input at
maximym flow rate
W
8,3
8,3
24,2
24,2
j)
Sound power level (Lwa)
dBA
47
47
63
63
k)
Reference flow rate
m3/h
83
83
253
253
l)
Reference pressure difference
Pa
10
10
10
10
m)
Specific power input (SPI)
W/m3/h
0,1
0,1
0,096
0,096
n1)
Control factor
-
1
0,65
1
0,65
n2)
Control typology
-
Manual Control
(no DCV)
Local Demand
Control
Manual Control
(no DCV)
Local Demand
Control
o1)
Maximum internal leakage
rate
%
N/A
o2)
Maximum external leakage
rate
%
N/A
p1)
Internal mixing rate
%
N/A
p2)
External mixing rate
%
N/A
q)
Visual filter warning
-
N/A
r)
Instructions to install
regulated grilles
-
check the instruction booklet
s)
Internet address for
pre/disassembly instructions
-
www.brookvent.co.uk
t)
Airflow sensitivity to pressure
variations
%
N/A
N/A
24
24
u)
Indoor/outdoor air tightness
m3/h
52
52
132
132
v1)
Annual electricity
consumption- warm climates
kWh
1,4
0,9
1,3
0,9
v2)
Annual electricity
consumption- average
climates
kWh
1,4
0,9
1,3
0,9
v3)
Annual electricity
consumption- cold climates
kWh
1,4
0,9
1,3
0,9
w1)
AHS - Annual heating saved -
warm climates
kWh
6,3
11,9
6,3
11,9
w2)
AHS - Annual heating saved -
average climates
kWh
14
26,2
14
26,2
w3)
AHS - Annual heating saved -
cold climates
kWh
27,3
51,3
27,2
51,3

14/14 brookvent.co.uk
7. CUSTOMER SUPPORT
At Brookvent we pride ourselves on providing Gold Standard after sales and support to all customers.
Please feel free to contact one of our specialist team about any query you may have, and we will be more
than happy to assist you.
Brookvent
Brook House,
Dunmurry Industrial Estate,
Dunmurry,
Belfast
Northern Ireland, BT17 9HU
T: +44 (0) 28 9061 6505
It is important to retain this manual and make a copy available to any person using or working with
(maintaining) the system.
Brookvent operate a policy of continuous innovation and improvement and thus reserve the right to alter
product specifications and appearances without notice.
V1 12.12.2022 UK
This manual suits for next models
18
Table of contents
Other BrookVent Fan manuals

BrookVent
BrookVent 90-0103-WDS-01 Mounting instructions

BrookVent
BrookVent AirVent SM 1200+ User manual

BrookVent
BrookVent airstream DMEV 100 HT Mounting instructions

BrookVent
BrookVent AIRVENT SM ACOUSTIC Operating instructions

BrookVent
BrookVent Aircycle 1.1 Instruction Manual

BrookVent
BrookVent aircycle 4.1 User manual

BrookVent
BrookVent AS 92-ACE-H-125 User guide

BrookVent
BrookVent AF 90-DMEV-100 User manual

BrookVent
BrookVent BTP EC 100 Mounting instructions