14
Caution in Regards to Combustibles – If any part of the
replace or objects in the room (curtains, rugs, paint,
cushions, etc.) start to show warping or discoloration due to
heat from the replace, it is time to take immediate action.
Each installation requires a different set of circumstances
to deal with the problem, but one thing is certain: do not
use the replace until you have gured out how to address
the problem. You are facing a potential re hazard. The
manufacturer of the Burntech® gas replace cannot be
responsible for the make-up of material on the exterior
of the replace you have chosen, nor can Burntech® be
held responsible for the materials in a room that may be
responding negatively to heat. However, in almost all
cases, there is a solution to the problem, either by making
adjustments to airow or the room itself.
Installing Outside Air
Be mindful that outside, fresh air is not required for the
operation of the Burntech® Fireplace. However, local
building codes may require combustion air and it is an
excellent choice in some situations, especially in weather
conditions where homes are very well insulated and
tightly sealed. Check local building codes for specic
requirements.
Install Outside Air Kit - BFP4-AK into the Burntech®
Firebox either through the side wall opening provided. The
tubing that goes out of the rebox wall must feed into a
exible metal conduit as the source for outside combustible
air. It can go straight out through an outside wall or into a
ventilated crawl space. If crawl space is used, check codes
for proper termination.
Be sure that you carefully check the source of the outside
air before you choose the site for your air intake. You don’t
want a place where snow will collect, where bushes or trees
will be growing or a location that is too close to any other
structure.
The suggested maximum height for the air intake tubing
is 50 ft. (fty feet) above the hearth. That height is if the
intake nishes off at a minimum of 3 ft. (three feet) below
the chimney cap level.
Install a screened termination cap to keep out animals.
Burntech® Chimney Systems
Overview
This Burntech® gas replace may be installed with an approved
10” B-vent chimney system. A metal chimney adapter is required
to attach the chimney to the top of the rebox. This can be
purchased from Burntech, part number TFS-DD.
Installers are cautioned to put the chimney system together
exactly as instructed and shown in chimney manufacturer’s
guide. Any variations may have serious consequences resulting
in an accident or malfunction. If instructions are not followed,
the warranty on the product will become null and void.
3.
1.
2.
3.
4.
5.
Note that the most important aspect of the installation is the
maintenance of minimum required clearances to combustible
materials. Those specic installation requirements must
be followed with great precision as you are dealing with the
potential of re hazard if the correct combustible limit is not met
and maintained. When you look at the drawings provided in this
section, you will see that actual installations may vary due to
individual design preferences. That is to be expected.
Design and framing specics may vary from the drawing
to installationy. Clearances to combustibles is a stringent
requirement.
WARNING:
If you do not use chimney manufacturer’s parts and/or if you
do not follow exact instructions for installation of chimney
components, you may be responsible for replace malfunction,
an accident or a re hazard.
Attention: Be advised that your choice of Chimney System
meets the following standards and requirements:
Designed for installation in accordance with National Fire
Protection Standard
Meets requirements of NFPA 211
Designed in accordance with BOCA Basic National Codes
Meets Uniform Building Codes.
General Chimney Requirements for Height and Clearance
When installed, the maximum overall height of the chimney
system from bottom of replace to the top/termination chimney
is 40 feet. The minimum installed height of the completed
Chimney System is 14 feet with a straight ue stack, 17 feet if
the chimney includes one or two offset sections.
Throughout the length of the chimney – along the outer
periphery of the ue you must have at least 1” (one inch) of
clearance all around the circumference. When the chimney is
passing through a living space, it must be completely closed off.
A “live” chimney is never allowed to be within reach of humans;
the chimney must be completely designed to be hidden from
view and protected, away from human interaction.
Note that it is acceptable for the chimney’s restop space and
roof ashing to come in direct contact with common construction
materials, such as drywall, ooring, paneling, plywood, millboard,
particle board and a variety of normal framing materials. Always
follow the specic installation requirements of your selected
chimney manufacturer.
Determining Finished Height for Fireplace
Determine the number of chimney sections and the chimney
components that will be required for the installation. Bear
in mind that the minimum height of the Burntech® Fireplace
System once installed is 14’-0” (fourteen feet) and that it is
higher if offsets are used. Here is how to calculate the height of
the completed replace:
●
●
●
●