BVA Hydraulics PS33L User manual

Printed in Taiwan
Maximum Operating Pressure 10,000 PSI
MODELS: PS33L, PS43L
Solenoid Control Valves
SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153
Tel: 888-332-6419 - Fax: 816-448-2142
PS33L-M0_012018
This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
Obey all safety messages that follow this symbol to avoid possible injury or death.
!
Pump Mounted
Instruction Manual
PS33L
PS43L

2
!
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that
follow this symbol to avoid possible injury or death.
• Study, understand, and follow all
instructions provided with and on this
device before use.
• All WARNING statements must be
carefully observed to help prevent
personal injury.
•
No alteration shall be made to this
device.
• Always wear protective gear when
operating hydraulic equipment.
• Keep hydraulic equipment away from
ames and heat. Hydraulic uid can
ignite and burn. Do not operate if
leaks are detected.
•
Crush Hazard. Keep hands and
feet away from loading area. Avoid
pinch points or crush points that can
be created by the load or parts of
cylinder.
•
To avoid crushing and related injuries:
NEVER work on, under or around
a lifted load before it is properly
supported by appropriate mechanical
means. Never rely on hydraulic
pressure alone to support load.
HYDRAULIC CYLINDERS
•
The user must be a qualied operator familiar with the
correct operation, maintenance, and use of cylinders. Lack of
knowledge in any of these areas can lead to personal injury.
• Do not exceed rated capacity of the cylinder or any equipment
in the system.
• Burst hazard exists if hose or connection pressure exceeds
rated pressure.
•
Inspect cylinder, hoses and connections before each use to
prevent unsafe conditions from developing. Do not use if
they are damaged, altered or in poor condition. Do not use a
cylinder with bent or damaged coupler or damaged threads.
•
Use gauge or other load measuring instrument to verify load.
• Do not subject the cylinder to shock loads.
• Never attempt to disconnect hydraulic connections under
pressure.
•
Use only approved accessories and approved hydraulic uid.
•
Never attach ANY component not authorized by manufacturer.
• Never use other than factory provided and/or authorized
fasteners.
• Under certain conditions, the use of an extension with a
hydraulic cylinder may not be advisable and could present
a dangerous condition.
• Cylinder must be on a stable base which is able to support
the load while pushing or lifting. Ensure cylinder is fully
engaged into/onto adapters, extension accessories.
• Use shims, friction material or constraints to prevent slippage
of the base or load.
• Distribute the load evenly across
the entire saddle surface. Do not
off-center loads on a cylinder.
The load can tip or the cylinder
can “kick out”.
• This device is not suitable for use as support device! As the
load is lifted, use blocking and cribbing to guard against a
falling load.
• All personnel must be clear before lowering.
• Never try to disassemble a hydraulic cylinder, refer repairs
to qualied, authorized personnel.
HYDRAULIC HOSES & FLUID TRANSMISSION LINES
• Avoid short runs of straight line tubing. Straight line runs
do not provide for expansion and contraction due to
pressure and/or temperature changes.
• Reduce stress in tube lines. Long tubing runs should be
supported by brackets or clips. Before operating the pump,
tighten all hose connections with proper tools. Do not
overtighten. Connections should only be tightened securely
and leak-free. Overtightening can cause premature thread
failure or high pressure ttings to burst.
• Should a hydraulic hose ever rupture, burst or need to be
disconnected, immediately shut off the pump and release
all pressure. Never attempt to grasp a leaking pressurized
hose with your hands. The force of escaping hydraulic uid
can inict injury.
• Do not subject the hose to potential hazard such as re,
sharp objects, extreme heat or cold, or heavy impact.
• Do not allow the hose to kink, twist, curl, crush, cut or bend
so tightly that the uid ow within the hose is blocked or
reduced. Periodically inspect the hose for wear.
• Do not pull, position or move setup by the hose.
• Hose material and coupler seals must be compatible with
hydraulic uid used. Hoses also must not come in contact
with corrosive materials such as battery acid, creosote-
impregnated objects and wet paint. Never paint a coupler
or hose.
•
FAILURE TO HEED THESE WARNINGS MAY RESULT IN
PERSONAL INJURY AS WELL AS PROPERTY DAMAGE.
Center load on cylinder
Save these instructions. For your safety, read and understand the information contained within. The owner and operator shall
have an understanding of this device and safe operating procedures before attempting to use this device. Instructions and safety
information shall be conveyed in operator's native language before use of this device is authorized. Make certain that the operator
thoroughly understands the inherent dangers associated with the use and misuse of the product. If any doubt exists as to the safe
and proper use of this product as outlined in this factory authorized manual, remove from service immediately.
Inspect before each use. It is recommended that, prior to each use, an inspection be done by qualied personnel and that any
missing or damaged parts be replaced with factory authorized replacement parts only. Any valve that appears to be damaged in
any way, is worn, leaking or operates abnormally shall be removed from service immediately until such time as repairs can be
made. Any valve that has been or suspected to have been subject to a shock load (a load dropped suddenly, causing the system
pressure to exceed 10,000 PSI), shall be removed from service immediately until checked by qualied personnel. Owners and
operators of this equipment shall be aware that the use and subsequent repair of this equipment may require special training
and knowledge.
WARNING
!

3
OPERATION (refer to schematic ow path, page 4)
BVA Pump Mounted Valves are tandem center valves. Tandem centered valves allow oil to ow from the pump to
tank when in the NEUTRAL position.
1. Tandem centered valves must be in "neutral" lever position before starting pump. To pressurize the pump manifold or the
application (cylinder, spreader, etc.), simply position the lever left or right of center.
2. PS33L and PS43L are valves equipped with a positive locking feature, these models will not permit movement of the load when
the handle is moved between positions.
Ensure that the rated working pressure of each pressurized attachment be equal to or greater than the rated working
pressure developed by the hydraulic pump.
BEFORE USE
1. Before using this product, read the owner's manual completely and familiarize yourself thoroughly with the product, its components
and recognize the hazards associated with its use.
2. Verify that the product and the application are compatible. If in doubt, call BVA Hydraulics Technical Service (888)332-6419.
3. Inspect before each use. Do not use if broken, leaking or damaged components are noted.
4.
Replace worn or damaged parts with BVA Hydraulics authorized replacement parts only.
5. Use adequate eye protection when operating or near this device.
6. Ensure method of conrming load is accurate and working properly. Have gauge or load cell accuracy veried by qualied
personnel on a yearly basis.
PRODUCT DESCRIPTION
BVA Pump Mounted Manual Control Valves are designed and manufactured for safe hydraulic operation to 10,000 psi.
SET UP
1. Connect and secure hoses, cylinders, ttings, gauges and pump etc. noting that the proper ports are connected. Always
secure threaded port connections with non-hardening pipe thread compound. Take care not to introduce compound into port
orices. Use an approved, high-grade pipe sealant to seal all hydraulic connections. When using teon tape, never apply the
tape over ends of ttings where it can be torn loose and get into the hydraulic system.
If you are not trained and familiar with installing a valve, please have an authorized BVA service center
perform this procedure.
TROUBLESHOOTING
1. System will not build pressure.
a. Check pressure setting of pump, see pump's service instruction.
b. Check and tighten all hydraulic connections.
c. If trouble is not corrected, remove cylinder and hoses from the valve, place a gauge directly in valve port A and turn valve
to advance position. If no pressure developed, the unit should be taken to service center. If pressure develops, the cylinder
or connections are the problem.
2. Cylinder will not hold load. This is an indication of worn or damaged seals. Unit must be replaced/repaired by service center.
MAINTENANCE
1. Inspect hoses and connections daily. Replace damaged components immediately with BVA Hydraulics parts only.
2. Tighten connections as needed. Use pipe thread sealing compound when servicing connections.
3. Always use clean, approved hydraulic uid and change as recommended or sooner if the uid becomes contaminated (never
exceed 400 hours). Follow pump manufacturers instructions for changing and adding hydraulic uid. Use only good quality
hydraulic uid. We recommend BVA FJZ01 or equivalent when using with hand pump, air pump or electric pump. Never use
brake uid, transmission uid, turbine oil, motor oil, alcohol, glycerin etc. Use of other than good quality hydraulic oil will void
warranty and damage the cylinder, pump, hose etc.
Storage
Depressurize pump, disconnect all hydraulic lines to prevent accidental operation. Wipe the unit clean. Store in a clean, dry
environment.
!
!

4
Valve
Operation
Valve
Type
Use with
Cylinder
Model Hydraulic Symbol Schematic Flowpath
Advance Hold Retract
Pump
Mounted,
Manual
3-way,
Tandem
Center
Single-
Acting
PW2
PW3
4-way,
Tandem
Center
Double-
Acting PW4
3-way,
3-position,
Tandem
Center,
Locking
Single-
Acting PW33L
4-way,
3-position,
Tandem
Center,
Locking
Double-
Acting PW43L
Solenoid
115V
Single
Acting PS33L
Double
Acting PS43L
PUMP MOUNTED DIRECTIONAL CONTROL VALVE DIAGRAM
TP
A
A
PT
B
P
A
T
P
A
T
P T
AB
PT
A
PT
A
PT
A
PT
A B
PT
A B
PT
A B
PT
A B
P T
A

5
MODELS: PS33L & PS43L
Solenoid Valve
Service Parts
SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153
Tel: 888-332-6419 * Fax: 816-448-2142
Note: Not all components of the device are replacement items, but are illustrated as a convenient reference of location
and position in the assembly sequence. To ensure safe and reliable performance, replace worn or damaged parts with
BVA authorized repair parts only and ALWAYS provide model and serial number when ordering.
Item Part Number Description Qty
1C33L 3W/3P Valve 1
C43L 4W/3P Valve 1
2 655011 Solenoid Control Device 1
3 E05-3-9990-108 Handheld Control Assembly 1
Parts List
1
2
3

6
MODEL: PS33L
Locking Valve
Service Parts
SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153
Tel: 888-332-6419 * Fax: 816-448-2142
Note: Not all components of the device are replacement items, but are illustrated as a convenient reference of location
and position in the assembly sequence. To ensure safe and reliable performance, replace worn or damaged parts with
BVA authorized repair parts only and ALWAYS provide model and serial number when ordering.
Item Part No. Description Qty.
1 D08-4-9000-103 LOCKING VALVE ASSY. 1
2 E05-6-3001-105 PIN 2
3 649-1-0095-507 SOCKET HEAD CAP SCREW 4
4 D08-6-1001-107 VALVE BLOCK 1
5 609-1-0075-105 HEX SOCKET PIPE PLUG 2
6 649-1-0063-504 SOCKET HEAD CAP SCREW 4
7 E05-6-1010-103 GASKET VALVE 1
8 E05-4-1004-200 ADAPTOR ASSY. 1
9 D05-6-1001-106 HEX SOCKET PIPE PLUG 1
10 E05-4-1012-108 CIRCULAR INTERNAL 1
12 601-7-0008-009 CHROME STEAL BEARINGS 1
- E05-3-9990-108 TWO BUTTON PENDANT SWITCH
ASSEMBLY (NOT SHOWN) 1
- D09-3-9951-107 ADAPTOR ASSY. REPAIR KIT 1
- D08-3-9950-108 VALVE ASSY., BOLT REPAIR KIT 1
*Repair requires special skills, knowledge, and equipment. Only an authorized service center may perform the repair
and/or replacement of these items. Contact BVA technical service for list of service centers.
PS33L Parts Illustration
1
2
3
4
5
9
10
12
7
6
8
Parts List

7
MODEL: PS43L
Locking Valve
Service Parts
SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153
Tel: 888-332-6419 * Fax: 816-448-2142
Note: Not all components of the device are replacement items, but are illustrated as a convenient reference of location
and position in the assembly sequence. To ensure safe and reliable performance, replace worn or damaged parts with
BVA authorized repair parts only and ALWAYS provide model and serial number when ordering.
Item Part No. Description Qty.
1 D08-4-1051-100 LOCKING VALVE ASSY. 1
2 E05-6-3001-105 PIN 2
3 649-1-0095-608 SOCKET HEAD CAP SCREW 4
4 D08-6-1002-109 VALVE BLOCK 1
5 609-1-0075-105 HEX SOCKET PIPE PLUG 2
6 649-1-0063-504 SOCKET HEAD CAP SCREW 4
7 E05-6-1010-103 GASKET VALVE 1
8 E05-4-1004-200 ADAPTOR ASSY. 1
9 D05-6-1001-106 HEX SOCKET PIPE PLUG 2
10 E05-4-1012-108 CIRCULAR INTERNAL 1
12 601-7-0008-009 CHROME STEAL BEARINGS 1
- E05-3-9990-108 TWO BUTTON PENDANT SWITCH
ASSEMBLY (NOT SHOWN) 1
- D09-3-9951-107 ADAPTOR ASSY. REPAIR KIT 1
- D08-3-9950-108 VALVE ASSY., BOLT REPAIR KIT 1
*Repair requires special skills, knowledge, and equipment. Only an authorized service center may perform the repair
and/or replacement of these items. Contact BVA technical service for list of service centers.
PS43L Parts Illustration
1
2
3
4
5
9
10
12
7
6
8
Parts List

8
Parts List
Electric Pumps
Service Parts
PART: D08-4-1050-108
SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153
Tel: 888-332-6419 * Fax: 816-448-2142
Not all components of the pump are replacement items, but are illustrated as a convenient reference of location and position in
the assembly sequence.
8
2
1
7
4
5
6
3
Model No. D08-4-1050-108
Item Part Number Description Qty
1N/A Locking Valve Block 1
2 D09-4-1013-109 Piston Assy. 1
-9 N/A Piston 1
-10 * Back-Up Ring 2
-11 *O-Ring 1
3 D09-4-1002-104 Seat Assy. 1
-12 N/A Seat 1
-13 * Back-Up Ring 1
-14 * O-Ring 1
4 601-7-0009-001 Steel Ball 1
5 512-2-0079-109 Spring 1
6 D09-4-1001-102 Spring Guide Assy. 1
-15 * O-Ring 1
Item Part Number Description Qty
-16 N/A Spring Guide 1
7 * O-Ring 4
8 D09-4-1014-101 Block-Unloading Assy. 1
-13 * Back-Up Ring 1
-14 * O-Ring 1
-15 * O-Ring 1
-17 N/A Block-Unloading 1
-18 N/A Neddle 1
-19 * Safety Spring 1
-20 N/A Adjustment Screw 1
-21 * O-Ring 1
-22 N/A Safety Valve Screw 1
* D09-3-9904-108 Locking Valve Assy. Repair Kit 1

9
2
1
7
4
5
6
3
3
4
5
6
Model No. D08-4-1051-100
Approved By:
Checked By:
Drawn By: 黃長發
Date: 2010.03.04
File name: D08-4-1051-100_1003EXP.slddrw
Parts List
Electric Pumps
Service Parts
PART: D08-4-1051-100
SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153
Tel: 888-332-6419 * Fax: 816-448-2142
Not all components of the pump are replacement items, but are illustrated as a convenient reference of location and position in
the assembly sequence.
Item Part Number Description Qty
1 D08-6-1050-100 Locking Valve Block 1
2 D09-4-1000-100 Piston Assy. 1
-8 N/A Piston 1
-9 * Back-Up Ring 2
-10 * O-Ring 1
3 D09-4-1002-104 Seat Assy. 2
-11 N/A Seat 1
-12 * Back-Up Ring 1
-13 * O-Ring 1
4 601-7-0009-001 Steel Ball 2
5 512-2-0079-109 Spring 2
6 D09-4-1001-102 Spring Guide Assy. 2
-14 * O-Ring 1
-15 N/A Spring Guide 1
7 * O-Ring 4
* D09-3-9905-100 Locking Valve Assy. Repair Kit 1

10
LIFETIME LIMITED WARRANTY
BVA Hydraulics®, represented in the United States by Shinn Fu Company of America, Inc. [“SFA”] warrants this
product to be free from defects in material and workmanship for the life of the product as long as the original
purchaser owns the product. The warranty is non-transferable and is subject to the terms, exclusions, and limitations
described below:
• Damaged components, including but not limited to bent rams, dented or crushed cylinder walls, broken welds or
couplers as well as worn out seals, o-rings and springs are the result of misuse and not covered by warranty and
BVA Hydraulics will not provide any warranty credit for such damaged components.
• This warranty does not cover ordinary wear and tear, overloading, alterations (including repairs or attempted
repairs not performed by BVA Hydraulics or one of its authorized personnel), improper uid use, or use of the
product in any manner for which the product was not intended or the use of which is not in accordance with the
instructions or warnings provided with the product.
• In the unlikely event that a BVA Hydraulics product fails due to material defect in workmanship, you may contact
SFA for disposition. In such cases, the customer’s sole and exclusive remedy for any breach or alleged breach
of warranty is limited to the repair or replacement of the defective product.
• Under no circumstances is BVA Hydraulics liable for any consequential or incidental damage or loss
whatsoever.
• THIS WARRANTY IS LIMITED TO NEW PRODUCTS SOLD THROUGH AUTHORIZED DISTRIBUTORS
AND OTHER CHANNELS DESIGNATED BY BVA HYDRAULICS. NO AGENT, EMPLOYEE OR OTHER
REPRESENTATIVE OF BVA HYDRAULICS IS AUTHORIZED TO MODIFY THIS WARRANTY.
• THE FOREGOING IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES,
INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FOR A
FITNESS FOR A PARTICULAR PURPOSE.
• Components not manufactured by BVA Hydraulics including certain motor systems, gasoline engines, and others
are not covered by this warranty and instead are covered by the manufacturer’s separate manufacturer’s warranty
provided in the package.
• BVA Hydraulics’ liability in all cases is limited to, and will not exceed the purchase price paid for the product.
SFA Companies
10939 N. Pomona Ave. Kansas City, MO 64153
Tel: 888-332-6419
E-mail: [email protected]

11
Contact:
SFA Companies
10939 N. Pomona Ave. Kansas City, MO 64153, U.S.A.
Tel:(888)332-6419 Fax:(816) 448-2142
BVA Website: http://www.bvahydraulics.com
Note Page

12
Contact:
SFA Companies
10939 N. Pomona Ave. Kansas City, MO 64153, U.S.A.
Tel:(888)332-6419 Fax:(816) 448-2142
BVA Website: http://www.bvahydraulics.com
Note Page
This manual suits for next models
1
Table of contents
Other BVA Hydraulics Control Unit manuals
Popular Control Unit manuals by other brands

NXP Semiconductors
NXP Semiconductors freescale TWR-TWRPI-BD quick start guide

Phidgets
Phidgets STC1001 manual

Edgewater Wireless Systems, Inc.
Edgewater Wireless Systems, Inc. EWC24GWFR1 user manual

MicRadar
MicRadar R60AFD1 Using Guide

Digi
Digi XBee manual

HKC
HKC APL-5 Series Installation, operation & maintenance manual