manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. C-Aire
  6. •
  7. Air Compressor
  8. •
  9. C-Aire CAMD1 User manual

C-Aire CAMD1 User manual

Other C-Aire Air Compressor manuals

C-Aire S33 User manual

C-Aire

C-Aire S33 User manual

C-Aire S110 User manual

C-Aire

C-Aire S110 User manual

C-Aire S244 User manual

C-Aire

C-Aire S244 User manual

C-Aire S280 User manual

C-Aire

C-Aire S280 User manual

C-Aire S244B User manual

C-Aire

C-Aire S244B User manual

C-Aire S260R-LD1-115P User manual

C-Aire

C-Aire S260R-LD1-115P User manual

Popular Air Compressor manuals by other brands

Craftsman 919.724591 owner's manual

Craftsman

Craftsman 919.724591 owner's manual

Atlas Copco GA 30+ Instruction book

Atlas Copco

Atlas Copco GA 30+ Instruction book

Hitachi Highly WHP11500VSDPC9EQ installation manual

Hitachi

Hitachi Highly WHP11500VSDPC9EQ installation manual

Craftsman 919.167810 owner's manual

Craftsman

Craftsman 919.167810 owner's manual

Yamato 24/2 M1CD instruction manual

Yamato

Yamato 24/2 M1CD instruction manual

Clarke 2242117 Operation & maintenance instructions

Clarke

Clarke 2242117 Operation & maintenance instructions

Sparmax DC-25XR user manual

Sparmax

Sparmax DC-25XR user manual

Briggs & Stratton Air Compressor Operator's manual

Briggs & Stratton

Briggs & Stratton Air Compressor Operator's manual

Fini F3GST2TK Operator's manual

Fini

Fini F3GST2TK Operator's manual

Campbell Hausfeld RP3300 Easy setup guide

Campbell Hausfeld

Campbell Hausfeld RP3300 Easy setup guide

Ingersoll-Rand UP6 20 HP Option manual

Ingersoll-Rand

Ingersoll-Rand UP6 20 HP Option manual

Parkside PKO 270 A1 operating instructions

Parkside

Parkside PKO 270 A1 operating instructions

Clas Ohlson QIE-ZTH-15 manual

Clas Ohlson

Clas Ohlson QIE-ZTH-15 manual

Ferm CRM1046 Original instructions

Ferm

Ferm CRM1046 Original instructions

BE AC153 Operation manual

BE

BE AC153 Operation manual

RIDGID OF25150A Operator's manual

RIDGID

RIDGID OF25150A Operator's manual

Johnson Controls QUANTUM LX Setup

Johnson Controls

Johnson Controls QUANTUM LX Setup

Ring Automotive RAC700 instructions

Ring Automotive

Ring Automotive RAC700 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

LL CAMD1 MANUAL // REV: 2 // October 25, 2022 C-Aire CAMD1 Owner’s Manual
Page 1of 2
CAMD1 Automatic Air Pressure Maintenance Device
Product Description
C-Aire's CAMD1 Air Pressure Maintenance Device is an
automatic, field-adjustable device of the pressure
reducing type. It is used to control the supervisory air
pressure in a dry pipe sprinkler system, pre-action
system, or dry pilot line system of a dry pilot sprinkler
actuated deluge or pre-action valve. The CAMD1 is
utilized in applications where there is a compressed air (or
nitrogen) source which is at a higher pressure than the
desired system pressure. Pressure sources include plant
air supplies having their own automatic compressor
controls, or nitrogen supplies having single stage cylinder
mounted pressure regulators.
The ½” valve is opened to admit air speedily to the dry
pipe system, also known as bypass mode. It is closed
once the desired system air pressure has been
established. As pressure drops on the system side of the
¼" check valve, the regulator and metering orifice operate
automatically to replace small losses of air which
periodically occur in the system due to temperature or
other system variations. The regulator and metering
orifice limit the volume of air introduced to assure that the
rate of air replacement is less than that from an operated
sprinkler so that system activation may take place.
Technical Data
Approval
FM
Maximum Pressure
175 psi
Pressure Output Range
5-60 psi
End Connections
½”Female NPT
Physical Specifications
Width: 9”
Height: 8½”
Weight: 3 lbs.
All Valves Vertical = Normal Operation
All Valves Horizontal = Bypass Mode
Installation
The C-Aire CAMD1 must be installed in accordance with
the following instructions.
Make connections a minimum of ½” pipe size between the
inlet air supply and the CAMD1, as well as between the
CAMD1 and the system to pressurize.
Remove 1/8” NPT plug from regulator and install pressure
gauge. Plug may be re-installed after setting system
pressure.
Bypass Mode Operation
1. Determine desired system pressure.
a. Consult dry pipe valve manufacturer for
assistance determining system pressure.
2. Turn all ball valve handles to the horizontal
position to enter bypass mode.
3. Fill system to approximately 5 PSI less than
desired system pressure.
4. Return ½” ball valve handle to vertical position
(closed) and proceed to setting system pressure
procedure.
: (651) 462-3440
: cairecompressors.com
: 380 West 1st Street, Dresser, WI 54009
LL CAMD1 MANUAL // REV: 2 // October 25, 2022 C-Aire CAMD1 Owner’s Manual
Page 2of 2
Setting System Pressure
1. Begin with system approximately 5 PSI less than
desired pressure and all ball valves closed (¼”:
Horizontal, ½”: Vertical).
2. Turn inlet side ¼” ball valve handle to vertical
position (open).
3. Loosen locking nut on regulator adjustment screw.
4. Turn adjustment screw clockwise to increase
pressure until desired pressure is displayed on
regulator gauge.
a. If gauge pressure exceeds desired
pressure turn screw counterclockwise until
pressure is 10 PSI below desired pressure
before turning clockwise until desired
pressure is shown on gauge.
5. Tighten locking nut on regulator adjustment screw.
6. Turn all ball valve handles to vertical position to
return to normal operation.
7. Allow system pressure to stabilize and adjust as
necessary.
CAMD1 Parts Diagram
Care and Maintenance
1. Note desired system pressure.
2. Depressurize plumbing prior to loosening any
fittings on the CAMD1.
3. Ensure all ball valves are in the closed position.
a. (¼”: Horizontal, ½”: Vertical)
4. Slowly remove cap on Y-Strainer, allowing any
remaining pressure to bleed out prior to fully
removing cap.
5. Clean strainer screen and cap.
6. Reinstall strainer screen and cap.
7. Return CAMD1 to normal operation by turning all
ball valve handles to the vertical position.
8. Inspect for leaks with a soapy water solution.
9. Ensure system reaches desired system pressure.