Cadac 346 User manual

MODEL No 346, 346-10-QR
DUAL POWER PAK
503-0386 LEV19
USER INSTRUCTIONS
NOTE! PRODUCT MAY VARY FROM ILLUSTRATIONS
EN DE DK ES FR IT NL NO PL SE
LIVE THE BRAAI LIFE
Model: 346-10-QR

11
CAUTION
Provide ample ventilation. This gas appliance consumes air (oxygen). Do not use this appliance in an unventilated space to
avoid endangering your life. If still more gas appliances and/or occupants using gas are added to the space, additional ventilation
must be provided.
IMPORTANT
Read these instructions carefully so as to familiarise yourself with the appliance before ting the appliance to a gas cylinder.
Retain these instructions for future reference.
EN
1. General
• The purpose of this appliance is to be a light weight, compact power source for CADAC camping products when the user
does not want to use a large LPG cylinder. The user simply connects two gas cartridges to the Dual Power Pak and then to a Grillogas /
Skottel / Carri Chef 50, or another compatible unit.
• This regulator complies with EN16129:2013
• Appliance category: I3B(28-30mbar) All EU, NO, IS, CH, TR, DE, AT and LU
• Appliance category: I3B(50mbar) DE, AT and LU
• Only to be used with EN417 type disposable cartridges (CADAC CA445,CA500).
• The gas cartridge is to be used only in the upright position.
• Gas appliances require ventilation for efcient performance and to ensure the safety of users and other persons in close proximity.
• The Power Pak is tted with a regulator with a maximum supply rate of 1.0kg/hour.
• The user may adjust the supply rate of the Power Pak unit by turning the control valve on the Power Pak from fully closed to fully open.
2. Safety information
• The Power Pak is guaranteed for a period of 2 years against factory faults. Natural
wear and tear and valve components. Plastic parts are excluded. The same applies
to damage caused by improper handling, misuse or repair by an unauthorized LP
gas dealer. Liability is limited to replacement to the replacement of products.
Never use in an unventilated room with all windows and doors closed.
• Never place the Power Pak on a stove, and always keep it at least 1 meter away
from any source of heat, and ensure it is not placed in an environment where the
temperature will exceed 50°C.
• Always store, transport or use the Power Pak in an upright position.
• When not in use, keep the valve closed, even if it is empty.
• Check that the seals (Fig. 1) are in place and in good condition before connecting
the gas container to the appliance. Do not use the appliance if it has a damaged or
worn seal. If in doubt, replace the seal before use.
• Do not use an appliance which is leaking, damaged or which does not operate
properly (malfunctioning).
• If you suspect a gas leak, soapy water must be applied to the joints (the appliance
must not be fully immersed in soapy water as this may result in an unsafe
operation of the appliance). Any leakage will be seen as bubbles coming from the
leakage point. If you cannot remedy any leakage, unscrew the gas cartridge from
the appliance and return the appliance to your stockist.
• The appliance should only be used in a well-ventilated location (minimum
ventilation requirement 5m3/h) in order to satisfy ofcial ventilation standards for
the supply of sufcient combustion air and to avoid the dangerous building up of
unburned gases.
• Gas cartridges must be tted or changed in a well-ventilated location, preferably
outside and away from any sources of ignition, such as naked ames, pilots,
electric res and away from other people.
• Never leave the appliance unattended when in use.
• Do not modify the appliance. Do not use it for anything for which it has not been designed.
• In normal conditions of use, in order to ensure the correct operation of the Power Pak, it is recommended that this regulator is
changed within 10 years of the date of manufacture.
• Do not move the Power Pak during operation.
• Do not use the Power Pak in small enclosed spaces without ventilation.
Fig. 1
G1/4” LH
Seal
1m
1m
1m
1m
7/16”
Country name abbreviations
AT=Austria DK=Denmark GB=UnitedKingdom NO=Norway
BE=Belgium ES=Spain IE=Ireland PL=Poland
CH=Switzerland FI=Finland IT=Italy PT=Portugal
DE=Germany FR=France NL=Netherlands SE=Sweden
SI=Slovenia

22
3. Operation of the Power Pak
• Before operating the appliance, ensure all seals are in good condition. If you are
unsure, replace the seals.
• Ensure that the hose is connected securely to the valve outlet of the Power Pak.
• Connect the other end of the hose securely to the appliance you wish to operate.
• First ensure the control knob on the appliance you are going to operateis in the
“off” position.
• Insert the two gas cartridges onto the unit by screwing them in place (Fig. 4).
• Turn the control knob on the Power Pak anti-clockwise to increase the gas ow (Fig.
2).
• Then turn on the appliance you wish to operate, and light the appliance.
• Adjust the control knob, to reach the desired level gas ow to the appliance.
• Heat control to be done using the appliance control knob.
Fig. 4
4. To disassemble the unit
• Close the control knob.
• Remove the cartridge by unscrewing it.
• Disconnect the hose from the appliance and pack the unit away for storage.
• Cartridges should always be stored in a cool, dry, well-ventilated area.
5. Checking for leaks (Gas cartridge)
• To check the gas cartridge for leaks, apply soapy water to the connection area of the gas cartridge and see if any bubbles are visible.
Any leakage will be seen as bubbles coming from the leakage point. If you cannot remedy any leakage, return the cartridge to your
stockist.
GBEN
6. Assembly
346
1: Hand wheel (17mm Hex) and hose component
2: Move the handle wheel to the end of the hose sliding it over the brass nut.
3: Connect brass nut to the inlet of the BBQ, turn the hand wheel to tighten.
Brass nut Hand Wheel
1. 2. 3.
Fig. 2 Fig. 3
(Low pressured gas)
High pressured gas
346-QR
1: Remove QR male.
2: Connect QR male to the inlet of your product and turn to tighten.
3: Connect QR female to QR male by pushing the QR female onto the QR male.
QR Male
1. 2. 3.
QR Female

2222
LIVE THE BRAAI LIFE
CADAC SA
P.O. Box 43196,
Industria, 2042 South Africa
Tel: +27 11 470 6600
Email: [email protected]
www.cadacinternational.com
CADAC EUROPE
Ratio 26, 6921 RW Duiven
The Netherlands
Tel: +31 26 319 7740
Email: [email protected]
www.cadacinternational.com
CADAC GERMANY
Ratio 26, 6921 RW Duiven
The Netherlands
Tel: +31 26 319 7740
Email: [email protected]
www.cadacinternational.com
CADAC FRANCE
Le Viallon, 42520 Veranne
France
Tel: +33 4 74 78 13 65
www.cadacinternational.com
CADAC SOUTH EAST EUROPE
Bulevar oslobodjenja 285
Tel: +381 11 339 2700
Email: [email protected]
www.cadac.rs
CADAC SCANDINAVIA
Millarco International A/S
Rokhøj 26
8520 Lystrup, Denmark
Phone: +45 87 43 42 00
www.millarco.com
CADAC ITALY
Brunner SRL/GMBH
via Buozzi, 8
39100 Bolzano (Italy)
Tel: +39 0471 542900
Email: info@brunner.it
www.brunnerinternational.com
CADAC CHINA
Room 807, Huayue International
Building, No.255 Tiangao Road,
South
Yinzhou business district,
Ningbo, China
Tel:+86 574 87723937
Email: [email protected]
CADAC DENMARK
Camper Fritid
Industrivej 11
6640 Lunderskov, Denmark
Tel.: +45 7558 5255
Email: info@camper.dk
www.camper.dk
CADAC FINLAND
OY KAMA FRITID AB
Koivuhaantie 2-4 B
01510 VANTAA
00358 20 792 0310
info@kamafritid.
CADAC IRAN
Robin Bazarganan Carin Co.
Unit D, 6th Floor, Negin Zafar
Building, No.1327,
Shariati Street, Tehran, Iran
Tel: +98 21 276 00 781
Mail: [email protected]
CADAC MOZAMBIQUE
Exclusive Brands Africa
492 Avenida Namaacha
Maputo, Mozambique
Tel: +258 21 406254
www.cadac.co.mz
CADAC NEW ZEALAND
Riverlea Group (Pty) Ltd
2A Maui Street, Pukete,
Hamilton 3200, New Zealand
Tel: +64 7 847 0204
Email: [email protected]
www.riverleagroup.co.nz
CADAC SWEDEN & NORWAY
KAMA FRITID AB
0046 36 353700
CADAC U.A.E.
Supreme Impex General Trading
LLC Ofce No. 1801-7 Latifa
Tower Sheikh Zayed Road
Dubai, UAE
CADAC ZAMBIA
Exclusive Brands Africa Limited
7225A Kachidza Road
Light Industrial Area
Lusaka, Zambia
Tel: +260 211 842015
Tel: +260977 345034
Email: [email protected]
CADAC ZIMBABWE
Exclusive Brands Africa
Unit 8 Birkenhead Park
43 Josiah Chinamano Street
Belmont, Bulawayo
Tel: +263 971 740 (Bul)
Tel: +263 479 2564 (Har)
www.cadac.co.zw
CADAC POLAND
Kamai
Wola Batorska 461
32-007 Wola Batorska Poland
Tel: +48 12 635 1373
Email: [email protected]
www.kamai.pl
CADAC Czech Rep.
RÖSLER Praha spol. s r.o.
K Horkám 19/21
102 00 Praha 10 Česká republika
Tel: +420 267 188 011
Email: info@rosler.cz
www.rosler.cz
CADAC UK
14 Deaneld Court,
Link59 Business Park,
Clitheroe, Lancashire,
BB7 1QS
United Kingdom.
Tel: +44 (0) 333 2000363
E:mail: [email protected]
www.cadacinternational.com
CADAC MONTENEGRO
City kvart Z1L6
81000 Podgorica, Montenegro
Tel 38220671446,
38269020063
E-mail: [email protected]
Other manuals for 346
2
This manual suits for next models
1
Other Cadac Industrial Equipment manuals
Popular Industrial Equipment manuals by other brands

Rockwell Automation
Rockwell Automation Allen-Bradley MagneMotion QuickStick Series Design guide

VORON
VORON Mobius2 quick start guide

Sumitomo
Sumitomo ASTERO BASA Maintenance manual

NCR
NCR 7702-K100 Kit instructions

Siemens
Siemens 8UD1 1 A Series operating instructions

Festo
Festo DGPI(L)-Series operating instructions