manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cairox
  6. •
  7. Controllers
  8. •
  9. Cairox S-TOUCH User manual

Cairox S-TOUCH User manual

V-One User Manual
English
Safety
The V-One is a precision tool for electronics prototyping. As with any such equipment, the V-One and the
accompanying materials and accessories should be handled with care.
Please review the following material to ensure a safe work environment and to maintain optimal machine
performance.
The V-One is not only an excellent tool for the seasoned electrical engineer but it is also a great way to teach
electronics. Never leave the V-One unattended while in use and supervise young and inexperienced users to
ensure safe operation.
The V-One is for use as-is. Any modifications to the machine or improper use without explicit approval and
direction from Voltera may damage the machine, may cause bodily harm, and will void your warranty.
In case of emergency or prior to performing any maintenance, please ensure power cable is disconnected
from the V-One.
Printing Platform
The heated bed is a multipurpose heater with a maximum temperature of 240°C that is used
to dry printing materials and reflow solder paste. When the heater is on, the LEDs on either
side of the V-One will glow red. While the LEDs are red, the printing platform is unsafe to touch
and can cause burns. Remove any combustible materials from the area when heater is in use.
Printing Materials
The V-One comes with 2 mL cartridges of printing material: conductive ink and solder paste.
Do not ingest and keep these materials away from mouth and eyes. Be sure to wash hands
well with soap and water before eating or drinking after handling.
The conductive ink is a combustible liquid and must be kept away from heat/sparks/open
flames/hot surfaces. No smoking. In case of fire, suitable extinguishing agents are: CO2,
powder or water spray. Fight larger fires with water spray or alcohol-resistant foam.
Please refer to the MSDS at voltera.io/msds for detailed information on proper handling and
disposal procedures.
Sharp Tools
The accessories included with the V-One contain sharp tools such as the probe and
dispensing nozzles. Always keep the tip caps on the probe and the dispenser while not in use
to prevent damage to the equipment and accidental injury.
Moving Parts
The V-One is an electromechanical device with motors, gears, and belts. Keep fingers away
from moving parts.
1
Protect The Probe
The probe is an essential accessory for dispensing. To ensure optimal performance:
Cleaning The V-One
Wet conductive ink can generally be wiped off using a paper towel or tissue. If inks get on your skin, wash
thoroughly with soap and warm water. Before handling the materials, be sure to refer to the material safety
data sheets available at voltera.io/msds.
Dried conductive ink that has not been baked can be cleaned by applying a small amount of isopropyl
alcohol and rubbing with a paper towel.
Conductive ink that has been baked is much more difficult to remove. Apply isopropyl alcohol to a burnishing
pad and rub vigorously. Repeat until the ink has been removed. Using sharp tools to remove the ink may
result in damage to the surface below or injury.
The V-One uses several limit switches for self calibration. To ensure optimal performance, clean these
switches regularly with a cotton swab and isopropyl alcohol. Failure to do so may result in poor dispensing
quality and broken nozzles. It is recommended to perform cleaning before starting a workflow to avoid
calibration errors.
Transporting The V-One
When moving the V-One, do so by lifting by the base with two hands. Avoid lifting the machine by the bridge.
For long distance transportation or shipping, it is recommended to store the V-One upright in the original
packaging to avoid any damage during travel.
Replacement Fuse
In the even of a blown fuse in the power inlet, contact technical support as a blown fuse may be a symptom
of a more serious issue. Use the table below to select a suitable replacement.
100 – 120 VAC 200 – 240 VAC
Ratings 5A 250VAC 3A 250 VAC
Fuse Style 5 X 20 mm
Response Time Fast
Approvals IEC 60127
Note: Be sure to disconnect the power cable from the V-One before installing the replacement fuse.
Replacement Power Cable
Please check the product label on the back of the V-One before using the table below to select a suitable
replacement.
100 – 120 VAC 200 – 240 VAC
Length >= 1,8 m
Ratings > 250 V, > 10A
Termination C 14 to Plug Type B C 14 to Plug Style F
Do not drop the probe or attempt to disassemble it.
Ensure the probe is in a safe place with the cap securely in place when it is not in use.
Ensure the contact pads on the probe cap are clean, if necessary use a cotton swab and use
isopropyl alcohol to clean them.
2
Prepare The Dispenser Assembly
The V-One comes with 2 identical dispensers for the 2 ink cartridges: conductive ink and solder paste. Be
sure the dispenser’s plunger is fully retracted before assembling. If the plunger is too far out it can push ink
out during assembly.
Run The Software
Note: The V-One may require a firmware update on startup. Do not disconnect or turn off the V-One during
the firmware update!
Maintenance
Protect The Nozzle
The golden rule of high quality dispensing is to protect the dispensing nozzle. If the nozzle tip is dented,
bent, broken, or contaminated with dry ink, print quality will suffer. To ensure optimal performance, follow the
guidelines below:
A clogged nozzle can be identified by either no or inconsistent material flow. A clogged nozzle can be the
result of many factors including improper material storage, expired material, or a damaged nozzle.
Note: Do not try to clear the clog by force. This can puncture the piston in the cartridge. Before replacing the
nozzle, be sure to inspect the clogged nozzle for damage and inspect the material cartridge for its expiration
date.
Refrigerate The Inks
If the inks were left out by accident, we recommend that you purge the fluid in the nozzle by manually turning
the dispensing gear gently. If no fluid is coming out you must replace the nozzle.
The conductive ink and solder paste must be stored in a refrigerator or a cool place between 4-10°C (40-
50°F), with caps on, to preserve their shelf life. The probe can be stored at room temperature.
1. Remove the dispensing cap from the cartridge sheath. Remove the green lids from the conductive
ink cartridge.
2. Insert conductive ink cartridge into the sheath with the ink level visible through the viewing window.
3. Twist the dispensing unit back into the cartridge sheath.
4. Carefully twist the nozzle onto the end of the cartridge.
1. Connect the V-One to your computer with the provided USB cable.
2. Turn on the V-One by pressing the power button.
3. Open the desktop application software.
Gently wipe the nozzle with a clean tissue to remove material build-up before and after use.
Always store the dispenser with the tip cap on to prevent accidental damage
When removing the tip cap, twist to loosen and then pull straight away from the nozzle.
3
Printer Anatomy
1
2
34
5
6
7
8
9
V-One (Front)
V-One (Back)
1
2
1
2
1
2
3
Probe Assembly Dispenser Assembly
1. Bridge
2. Base
3. Carriage Gear
4. Probe Pins
5. Mounting Rods
6. Carriage
7. Calibration Switches
8. Heated Bed
9. Power Button
1. USB (Type B)
2. Power (C14 Receptable)
1. Contact Pads
2. Probe Tip
1. Ink Level Window
2. Dispensing Gear
3. Dispensing Plunger
4
V-One Technical Specifications
Disclaimer: Voltera reserves the right to change or update the following specifications at
any time without notice. Please visit voltera.io/store or contact [email protected] for
the most up-to-date information.
Hardware
Maximum Dimensions 40 x 26 x 21 cm 16 x 11 x 9 in
Weight 7 kg 16 lbs
Environmental Conditions
Operating Temperature 15 – 30º C 59 – 86ºF
Maximum Altitude 2000 m 1.24 miles
Relative Humidity 80%
Pollution Degree 2
Maximum Temperature 240ºC 464ºF
Ramp rate 2º C/s 3,6ºF/s
Power Requirements
Voltage 100 – 120 VAC 200 – 240 VAC
Current 4.7 A 50/60 Hz 2.5 A 50/60 Hz
Power 575W
Software
System Requirements Windows 7 and up (64 bit) Mac OSX 10,11 and up
Input File Type Gerber
Connection Type Wired USB
Printer Properties
Technology Direct-Write Dispensing
Magnetically Interchangeable Print Head
Height Control Active Height Mapping With Detachable Probe
20 um Repeatability
Print Area 13.5 x 11.4 cm 5.3 x 4.4 in
XYZ Resolution 10 ; 10 ; 0.625 um respectively
Feature Size
Minimum Line Dimensions* 0.2mm Space/Trace 8 mil Space/Trace
Minimum Dot Diameter* 0.5 mm 0.019 in
*With standard 9 mil (inside diameter) nozzle
5
Consumables & Accessories
The items below are compatible consumables.
Please visit voltera.io/store to view or purchase
additional consumables.
The items below are the compatible accessories. In
the case of damaged or lost accessories, please
contact [email protected] for replacements.
Setting Up Your V-One
Install The Software
Drivers: Before you install the V-One software it is important to install the printer drivers. Most connection
issues experienced are because the wrong drivers are being used.
Application: Visit voltera.io/downloads to download the desktop application.
Unbox And Choose a Location For Your V-One
2 ml Conductive Ink Cartridge
2 ml Solder Paste Cartridge
3 g Flux
10 g SniAg1 Solder Wire
Precision Dispensing Nozzles – Pack of 4
Burnishing Pad – Pack of 3
3” x 4” Substrate – Pack of 6
2” x 3” Substrate – Pack of 10
4” x 5” Substrate – Pack of 6
Probe Assembly
Dispenser Assembly
Substrate Clamps
Thumbscrews
Windows 7 and up (64-bit only) - Visit voltera.io/downloads to download the drivers. Remember to
install the drivers with administrator privileges.
Mac OSX 10.11 and up - Apple’s native drivers work with the V-One out of the box. There is no need
to install a separate driver.
1. Place the V-One on a flat, level, and non-flammable surface. Be sure to position the V-One so that
the power inlet is easily accessible.
2. A well ventilated area is recommended.
3. Remove all items from the box. Place the ink and solder paste in the fridge for storage.
4. Make sure you keep all packaging in case the product needs to be transported in the future.
5. Check the voltage rating on the back of the unit to make sure it matches the power provided in the
country of use.
6. Connect the provided power cable to the C14 receptacle at the back of the V-One, then to a earthed
socket outlet.
7. Connect the provided USB cable to the V-One, then to your computer.
6
For consumables and replacement parts, please
contact our sales team or visit our online store:
[email protected]
+1 88-381-3332 Ext. 1
voltera.io/store
For technical assistance, please reach out to our
technical support team:
[email protected]
+1 88-381-3332 Ext. 2
voltera.io/support
Voltera
113 Breithaupt St. Suite 100
Kitchener, ON, Canada, N2H 5G9

Other manuals for S-TOUCH

1

Other Cairox Controllers manuals

Cairox S-TOUCH User manual

Cairox

Cairox S-TOUCH User manual

Cairox TSC-1 Series Product information sheet

Cairox

Cairox TSC-1 Series Product information sheet

Cairox TSCTK-1 Series Product information sheet

Cairox

Cairox TSCTK-1 Series Product information sheet

Popular Controllers manuals by other brands

RKC INSTRUMENT CD101 instruction manual

RKC INSTRUMENT

RKC INSTRUMENT CD101 instruction manual

Redback A 4500B operating manual

Redback

Redback A 4500B operating manual

Siemens 3VL971 Series operating instructions

Siemens

Siemens 3VL971 Series operating instructions

KNX Module SAS-04.16 quick guide

KNX

KNX Module SAS-04.16 quick guide

DeZurik MO manual

DeZurik

DeZurik MO manual

Ingersoll-Rand ARO 651763-AM-2 user manual

Ingersoll-Rand

Ingersoll-Rand ARO 651763-AM-2 user manual

Pioneer DDJ-ERGOlimited quick start guide

Pioneer

Pioneer DDJ-ERGOlimited quick start guide

Gree CE53-24/F(C) owner's manual

Gree

Gree CE53-24/F(C) owner's manual

Alcorn Mcbride V+ series user guide

Alcorn Mcbride

Alcorn Mcbride V+ series user guide

Company NA Master Fade user manual

Company NA

Company NA Master Fade user manual

EXAIR EFC Installation and Maintenance

EXAIR

EXAIR EFC Installation and Maintenance

Deif PPU 300 Operator's manual

Deif

Deif PPU 300 Operator's manual

Sensibo Sensibo Air installation manual

Sensibo

Sensibo Sensibo Air installation manual

Veichi SI10 manual

Veichi

Veichi SI10 manual

Jetter JC-975MC installation manual

Jetter

Jetter JC-975MC installation manual

Mitsubishi Electric MELSEC iQ-R Series Safety function block reference

Mitsubishi Electric

Mitsubishi Electric MELSEC iQ-R Series Safety function block reference

Emerson Fisher FIELDVUE DVC6000 HW2 instruction manual

Emerson

Emerson Fisher FIELDVUE DVC6000 HW2 instruction manual

SKYTRONIC 103.112 instruction manual

SKYTRONIC

SKYTRONIC 103.112 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.