CALI LipLeds LLED8700-OL User manual

CALIFORNIA ACCENT LIGHTING, INC.
2034 E. Lincoln Ave. #431, Anaheim, CA 92806
ph. 800.921.CALI (2254) or 714.535-7900 \ fx. 714.535.7902
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specications without prior notice.
Installation Instructions Overview
LLED8700-OL
1 of 12
lipLEDs™
Frosted Lens Cover
(#LLED8700-OL-LF)
End Cap
(#LLED8700-OL-EC)
Aluminum Extrusion
(#LLED8700-OL)
Power Connector
(#LLED8700-PC)
End View
1.20”
1.46”
1.20”
1.46”
INSTALLATION TOOLS REQUIRED
WARNING
• Do not power lipLEDs when coiled or bunched together.
Maintain half inch spacing between parts when lit
• Do not cover lipLEDs as the covering may cause it to overheat, melt, or ignite
• Do not puncture or damage lipLEDs
• Do not route lipLEDs through walls, doors, windows, or building structures
• Do not roll out lipLEDs on rough surfaces or over sharp corners.
• Do not use lipLEDs if damaged, such as, broken outer jacket, loose
connections, or frayed wire insulation. Inspect periodically
• Do not secure lipLEDs with staples, nails, or like means that might
damage the insulation. Secure using mounting clips or mounting channel
• Do not submerge lipLEDs in liquid or install near standing water or
other liquids
• Do not install lipLEDs where it is subject to continuous flexing
• Do not mount lipLEDs inside cabinets, tanks, or enclosures of any
kind without proper ventilation
• Do not run lipLEDs at an operation temperature exceeding 65C or 149F or
below -20C or -4F
• Use only standard outdoor extensions cords, such as, SW, STW, STOW,
SJW, SJOW, SJTW, and SJTOW
• Ground Fault Circuit Interruptor (GFCI) protection is required on
circuits or outlets when lipLEDs is used for outdoor applications
• Surge protector must be set up for electrical power system to avoid
damaging lipLEDs lighting system
• Electric Compound Miter Saw
• 14.4 to 28 Volt Cordless Drill
• Wire Strippers for 22 and 15
gauge wire
• Pliers
• Wire Cutter
• Phillips Bits - Sufficient Quantity
• Carbide Masonry Drill Bits -
Sufficient Quantity
• Concrete Tapcon Screws
• Self Drill Metal Screws #4 x 1/2”
- Sufficient Quantity
• Electrical Cords
• Electrical Three Way
• Safety Glasses
• Measuring Tape
• Marker
• Chalk Line
IMPORTANT VERIFY CORRECT
LUMINAIRE WAS RECEIVED WITH
CORRECT COLOR TEMPERATURE
AND VOLTAGE BEFORE CUTTING
OR INSTALLING. CALI WILL NOT
BE RESPONSIBLE IF INCORRECT
LUMINAIRE IS INSTALLED.
2” increments up to max run
± 0.125” cutting tolerance
*See max run for more information
2”
6” increments up to max run
*See max run for more information
6”
2” increments up to max run
± 0.125” cutting tolerance
*See max run for more information
(Run lengths required)
2”
3.9” or 6.5”
6.5”
2” increments up to max run
± 0.125” cutting tolerance
*See max run for more information
2”
8’ Maximum extrusion and lens length
8’ Maximum extrusion and lens length
(Dry Location field cuttable)
Lens and extrusion shipped in
8’ sections (field cuttable)
8’ Maximum extrusion and lens length
3.95” increments up to max run
± 0.125” cutting tolerance
*See max run for more information
3.95”
LLED8400 --->
LLED8000 --->
LLED8200 --->
LLED8300 --->
LLED8500 --->
LLED8100 --->
Specify Length (19.7”Assembly Increments)
(Add 2.5” to run for end cap and strain relief)
.75”
5.5W
.78”
.52”
*1.5W, 2.5W,
3.6W, 4.5W
.47”
.36”
6.5” (2.5W) or 3.9” (5.5W) increments up to max run
± 0.125” cutting tolerance
*See max run for more information
6.5“ increments up to max run
± 0.125” cutting tolerance
*See max run for more information
2” increments up to max run
± 0.125” cutting tolerance
*See max run for more information
2”
6” increments up to max run
*See max run for more information
6”
2” increments up to max run
± 0.125” cutting tolerance
*See max run for more information
(Run lengths required)
2”
3.9” or 6.5”
6.5”
2” increments up to max run
± 0.125” cutting tolerance
*See max run for more information
2”
8’ Maximum extrusion and lens length
8’ Maximum extrusion and lens length
(Dry Location field cuttable)
Lens and extrusion shipped in
8’ sections (field cuttable)
8’ Maximum extrusion and lens length
3.95” increments up to max run
± 0.125” cutting tolerance
*See max run for more information
3.95”
LLED8400 --->
LLED8000 --->
LLED8200 --->
LLED8300 --->
LLED8500 --->
LLED8100 --->
Specify Length (19.7”Assembly Increments)
(Add 2.5” to run for end cap and strain relief)
.75”
5.5W
.78”
.52”
*1.5W, 2.5W,
3.6W, 4.5W
.47”
.36”
6.5” (2.5W) or 3.9” (5.5W) increments up to max run
± 0.125” cutting tolerance
*See max run for more information
6.5“ increments up to max run
± 0.125” cutting tolerance
*See max run for more information

CALIFORNIA ACCENT LIGHTING, INC.
2034 E. Lincoln Ave. #431, Anaheim, CA 92806
ph. 800.921.CALI (2254) or 714.535-7900 \ fx. 714.535.7902
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specications without prior notice.
Installation Instructions Overview
LLED8700-OL
2 of 12
lipLEDs™
Symmetric Forward Phase-Control
WARNING
When using lipLEDs for any application, basic safety precautions
should always be followed to reduce the risk of fire, electric shock,
and personal injuries. lipLEDs must be installed in accordance with
the NEC or CEC as applicable.
• Do not install lipLEDs in hazardous locations or closer than 6” from
any curtain or similar combustible material.
• lipLEDs have line voltage risk of shock. Consult factory for any
malfunctions. Do not attempt to repair.
• Use lipLEDs with specified rated voltages. Do not exceed the
specified voltage for any lipLEDs luminaire.
• Ensure power is off before installation begins, during replacements,
additions, or repairs.
• Do not cover lipLEDs as the covering may cause LEDs to overheat,
melt, and even ignite the covering.
• Do not use lipLEDs if damaged, such as, broken boards, loose
connections, or frayed wire insulation. Inspect before installing.
• Do not secure lipLEDs with nails, or like means that might damage
the wiring inside. Secure it by using mounting clips.
• Do not submerge lipLEDs in liquid.
• Do not install lipLEDs on places where it is subject to
continuous flexing.
• Do not mount lipLEDs inside tanks or enclosures of any kind without
proper ventilation.
• Do not drill holes or break any barrier on lipLEDs aluminum housing,
end caps, or lens covers.
• Do not use lipLEDs extrusion as a raceway for additional wire.
Non-factory feed-through wires inside lipLEDs will void warranty.
• Ground Fault Circuit Interrupter (GFCI) protections are required
on circuits or outlets when lipLEDs is installed.
• Surge protector must be set up for electrical power system to avoid
damaging lipLEDs lighting system.
DIMMING PROTOCOL (Forward Phase Dimming)
Technical Requirements for Control Equipment (Forward Phase Dimming)
• Electrical Characteristics - Inductive
• Special Requirements - Symmetric cycles
(VDC≤2), smooth turn off
APPLICATIONS Accent, Decorative Lighting
VOLTAGE 120V
LAMP TYPE LEDs
DIMMING Triac
LENGTH Built to Order
MOUNTING Pendant Mount
EFFICACY 2W: 114 Lumens per foot
4W: 228 Lumens per foot
CRI > 82
VIEWING ANGLE 120 Degrees
LED LIFE 50,000 hrs.
MAXIMUM RUN 80’ (PC-4AMP), 30’ (PC-1.6AMP)
LISTING Dry/Damp, or Wet Location
FEATURES

CALIFORNIA ACCENT LIGHTING, INC.
2034 E. Lincoln Ave. #431, Anaheim, CA 92806
ph. 800.921.CALI (2254) or 714.535-7900 \ fx. 714.535.7902
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specications without prior notice.
Installation Instructions
LLED8700-OL
3 of 12
lipLEDs™
Product Care
Do not bend lightstrip to a diameter of less than the following:
Do not cut power cord with rectifier.
Do not connect lightstrip to power source while spooled or coiled Do not overlap lightstrip at any location
Do not cover or penetrate lightstrip with any material
Do not apply excessive pressure to surface of lightstrip
Do not overlap extrusions in any way. Channel must be on flat, flush surfaceDo not install lightstrip in a zig zag fashion
Do not install wet location in outdoor cove without proper drainage
Do not install lightstrip with damaged seals
or without shrink tube in wet location
Do not cross extrusions and twist lightstrip to overlap
Do not bend lightstrip along a horizontal plane
Do not apply excessive pressure to rectifier
Do not use a lighter to heat shrink tube
2” 2”
<1.5”
<1.5”
(<38.1mm)
(<38.1mm)
White (-)
Red (+)
Black (-)
Blue
(Neutral)
Brown
(Hot)
Line
Green
(Ground)
Optional Dimmer
(not included)
Blue (+)
TRA
6”
4”
<1.5”
<1.5”
<12”
<8”
Rectifier
<12”
<8”
Rectifier
<12”
<8”
Rectifier
<12”
<8”
Rectifier
<12”
<8”
Rectifier
<12”
<8”
Rectifier
<12”
<8”
Rectifier
<12”
<8”
Rectifier
<12”
<8”
Rectifier
<12”
<8”
Rectifier
<12”
<8”
Rectifier
<12”
<8”
Rectifier
<12”
<8”
Rectifier
<12”
<8”
Rectifier
<12”
<8”
Rectifier

CALIFORNIA ACCENT LIGHTING, INC.
2034 E. Lincoln Ave. #431, Anaheim, CA 92806
ph. 800.921.CALI (2254) or 714.535-7900 \ fx. 714.535.7902
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specications without prior notice.
Installation Instructions
LLED8700-OL
4 of 12
lipLEDs™
Application Guidelines
One person on one end applies pressure
to LLED8700, securing it to channel
Leave a 0.5” gap between end of channel and
beginning of sealed power cord and end cap
LLED8700-OL REQUIRES A TEAM EFFORT TO ENSURE SECURE AND CORRECT INSTALLATION
Another person unreels LLED8700 from
spool, holding lightstrip at 45° angle
45°
Apply pressure to
lightstrip, ensuring
adherence to channel
Feed from wire puller stand
Channel
Double-sided tape supplied by others
IMPORTANT NOTE TO AVOID COLOR SHIFT:
• Do not paint on or over fixture lens or LEDs. Paint or any other substance on lens or LEDs will cause a shift in color temperature.
• Soffit must be painted evenly with a neutral white to avoid color shift.

CALIFORNIA ACCENT LIGHTING, INC.
2034 E. Lincoln Ave. #431, Anaheim, CA 92806
ph. 800.921.CALI (2254) or 714.535-7900 \ fx. 714.535.7902
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specications without prior notice.
Installation Instructions
LLED8700-OL
5 of 12
lipLEDs™
Power Connector
LLED8700-PC-1.6AMP-XX
(XX = specify) 2w or 4W)
LLED8700-PC-4AMP-XX
(XX = specify) 2w or 4W)
Maximum run with 1.6 Amp power connector: 30’
Rectifier measures 2.1” x 1.2” x .63”
Maximum run with 4 Amp power connector: 80’
Rectifier measures 3.7” x 2.34” x 1.27”
34”
.63”
2.1”
1.2”
34”
36.5”
2.34”
37.5”
1.27”
3.7”
12”
34”
.63”
2.1”
1.2”
34”
36.5”
2.34”
37.5”
1.27”
3.7”
12”

CALIFORNIA ACCENT LIGHTING, INC.
2034 E. Lincoln Ave. #431, Anaheim, CA 92806
ph. 800.921.CALI (2254) or 714.535-7900 \ fx. 714.535.7902
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specications without prior notice.
Installation Instructions
LLED8700-OL
6 of 12
lipLEDs™
Wiring Diagrams
Feed wire into junction box and secure with strain relief fitting.
TIP: Leave enough excess wire for feed to junction box to be relaxed.
Cut power plug near the end and strip jacket, exposing about 1” of wire.
NOTE: Do not remove rectifier from power cord.
Feed wire into weatherproof junction box and secure with weatherproof
strain relief fitting.
TIP: Leave enough excess wire for feed to junction box to be relaxed.
Dry Location Hardwiring
Dry Location Wiring Diagram
Cutting the Power Plug (If Applicable)
Wet Location Wiring Diagram
Wet Location Hardwiring
Service loop
Rectifier
(Do not remove)
Junction box
(by others)
Cord grip
(by others)
Weatherproof
junction box
(by others)
Weatherproof
cord grip
(by others)
Service loop
Rectifier
(Do not remove)
J box
(by others)
Hot Black (Hot)
Neutral
Rectifier
White (Neutral)
Weatherproof
J box
(by others)
Hot Black (Hot)
Neutral
Rectifier
White (Neutral)
White (Neutral)
Black (Hot)
White (Neutral)
Black (Hot)

CALIFORNIA ACCENT LIGHTING, INC.
2034 E. Lincoln Ave. #431, Anaheim, CA 92806
ph. 800.921.CALI (2254) or 714.535-7900 \ fx. 714.535.7902
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specications without prior notice.
Installation Instructions
LLED8700-OL
7 of 12
lipLEDs™
Preparing Fixture (Dry Location)
1. Measure area where LLED8700-OL will be installed.
RECOMMENDATION: Use chalk line to ensure a straight installation.
2. Drill holes as needed with drill bit and countersink.
3. Screw channel into desired surface using countersink holes.
NOTE: Surface must be flat.
4. Remove adhesive backing .
5. Install lightstrip into channel.
Countersink hole
LLED8700
Channel
Remove adhesive backing
Adhere lightstrip to channel
6. Snap lens into channel.
Ensure screw is flush with channel
Ensure lens is
snapped in place
7. Conduct continuity test.
8. Set voltmeter to AC voltage, then test power source before connecting.
9a. Connect using power plug.
If a conductive
path is formed
between hot and
neutral wires on
power plug, the
multimeter will
beep. You need to
trouble shoot to
find the short.
If there is no
conductive path
between hot and
neutral wires, the
multimeter will
not beep.
Troubleshoot Good
VAC
OFF VDC
ACOM
Ω
VΩ
VAC
OFF VDC
ACOM
Ω
VΩ
+ -
DCA
OFF DCV
ACOM
Ω
VΩ
DCA
OFF DCV
ACOM
Ω
VΩ
VAC
OFF VDC
ACOM
Ω
VΩ
VAC
OFF VDC
ACOM
Ω
VΩ
+ -
DCA
OFF DCV
ACOM
Ω
VΩ
DCA
OFF DCV
ACOM
Ω
VΩ
See page 10 for troubleshooting guide
Confirm the correct
voltage 120VAC
Power source
ACV
VAC
OFF VDC
ACOM
Ω
VΩ
VAC
OFF VDC
ACOM
Ω
VΩ
+ -
DCA
OFF DCV
ACOM
Ω
VΩ
DCA
OFF DCV
ACOM
Ω
VΩ
GFCI
GFCI
(not included)
9b. Connect using a hardwire connection.
J Box
(not included)
Cordgrip
(not included)
Black (Hot)
White (Neutral)
See page 6 for additional details

CALIFORNIA ACCENT LIGHTING, INC.
2034 E. Lincoln Ave. #431, Anaheim, CA 92806
ph. 800.921.CALI (2254) or 714.535-7900 \ fx. 714.535.7902
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specications without prior notice.
Installation Instructions
LLED8700-OL
8 of 12
lipLEDs™
Preparing Fixture (Wet Location)
5. Apply silicone at end of run to seal fixture.
Apply silicone
4. Snap lens into channel.
1. Measure area where LLED8700-OL will be installed.
RECOMMENDATION: Use chalk line to ensure a straight installation.
3. Remove adhesive backing, then install lightstrip into channel.
Countersink hole
LLED8700
Channel
Remove
adhesive backing
Adhere lightstrip
to channel
Ensure screw is
flush with channel
Ensure lens is
snapped in place
2. Drill holes as needed with drill bit and countersink, then screw channel
to desired surface using countersink holes.
NOTE: Surface must be flat.
6. Conduct continuity test.
7. Set voltmeter to AC voltage, then test power source before connecting.
8a. Connect using power plug.
If a conductive
path is formed
between hot and
neutral wires on
power plug, the
multimeter will
beep. You need to
trouble shoot to
find the short.
If there is no
conductive path
between hot and
neutral wires, the
multimeter will
not beep.
Troubleshoot Good
VAC
OFF VDC
ACOM
Ω
VΩ
VAC
OFF VDC
ACOM
Ω
VΩ
+ -
DCA
OFF DCV
ACOM
Ω
VΩ
DCA
OFF DCV
ACOM
Ω
VΩ
VAC
OFF VDC
ACOM
Ω
VΩ
VAC
OFF VDC
ACOM
Ω
VΩ
+ -
DCA
OFF DCV
ACOM
Ω
VΩ
DCA
OFF DCV
ACOM
Ω
VΩ
See page 10 for troubleshooting guide
Confirm the correct
voltage 120VAC
Power source
ACV
VAC
OFF VDC
ACOM
Ω
VΩ
VAC
OFF VDC
ACOM
Ω
VΩ
+ -
DCA
OFF DCV
ACOM
Ω
VΩ
DCA
OFF DCV
ACOM
Ω
VΩ
GFCI
Leave clearance
Weatherproof outlet protector
(by others)
GFCI
(not included)
Mount rectifier outside
of outlet protector
9b. Connect using a hardwire connection.
Weatherproof J Box
(not included)
Weatherproof Cordgrip
(not included)
Black (Hot)
White (Neutral)
See page 6 for additional details

CALIFORNIA ACCENT LIGHTING, INC.
2034 E. Lincoln Ave. #431, Anaheim, CA 92806
ph. 800.921.CALI (2254) or 714.535-7900 \ fx. 714.535.7902
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specications without prior notice.
Installation Instructions
LLED8700-OL
9 of 12
lipLEDs™
Hanging Mounting Clip
1. Measure area where LLED8700-OL will be installed.
RECOMMENDATION: Use chalk line to ensure a straight installation.
3. Mount aircraft cables at locations as marked.
RECOMMENDATION: 3/16” aircraft cable
4. Snap mounting clips into fixture using the same spacing.
5. Install set screw to prevent mounting clip from sliding.
6. Feed cable through loop and secure with a cable lock (not included).
2. Mark location where mounting clips will be installed.
RECOMMENDATION: Quantity of mounting clips = quantity of fixture +1.
Use a mounting clip at the joint between two fixtures.
PUSH PUSH
PUSHPUSH
PUSH PUSH
PUSH PUSH
PUSH PUSH
Chalk line
20’
Install set screw
Cable lock or compression
sleeve (supplied by others)
Set screw
Feed aircraft cable
through loop

CALIFORNIA ACCENT LIGHTING, INC.
2034 E. Lincoln Ave. #431, Anaheim, CA 92806
ph. 800.921.CALI (2254) or 714.535-7900 \ fx. 714.535.7902
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specications without prior notice.
Installation Instructions
LLED8700-OL
10 of 12
lipLEDs™
Troubleshooting
TROUBLESHOOT
• Do not reset breaker or GFCI multiple times.
• If the unit is overloaded the breaker will trip shutting off the lights.
• If the breaker or GFCI reset button has been held down by hand or
any type of pressure (example: duct tape), or if the breaker has been
reset multiple times without trouble shooting, the unit will:
- Burn the primary or secondary wires due to high amperage caused
by overload and/ or short circuit in line which will not allow the
breaker to reset
- Damage the lighting
1. Turn off power before beginning. Check for any twisting or damage to
the circuit in the LED lightstrip. If there is excessive damage and
circuit is broken, the lightstrip must be replaced.
2. Check for metal particles or other foreign objects causing the short.
3. Check if cut is clean and not frayed, causing positive and negative
copper nodes to touch.
4. Ensure the run is not too long and overlapping.
5. Ensure copper nodes are not making contact with aluminum extrusion.
6. Check for water inside end cap or power connector. Water needs to be
removed before connecting to power.
7. Reset GFCI after steps have been checked, then follow steps 5 - 7 on
page 7 for Dry Location, or follow steps 6 - 8 on page 9 for Wet Location.
Metal flakes
Foreign object
Metal flakes
Foreign object
Frayed end
Damaged lightstripTorn lightstrip
Twisted lightstrip
Excess lightstrip overlapping and held down with tape or other force
Copper nodes touching extrusion
Water inside power connector
Compromised seal
Water inside end cap Compromised seal

CALIFORNIA ACCENT LIGHTING, INC.
2034 E. Lincoln Ave. #431, Anaheim, CA 92806
ph. 800.921.CALI (2254) or 714.535-7900 \ fx. 714.535.7902
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specications without prior notice.
Installation Instructions
LLED8700-OL
11 of 12
lipLEDs™
Surge Protector (Not Included)
PRODUCT FEATURES
The Surge Series are 3-leaded devices that protect Line-Ground, Line-
Neutral, and Neutral-Ground in accordance with IEEE / ANSI C62.41.2
guidelines. Protects against surges according to IE EE C62.41.2 C High
(10kA and 10kV). Surge current rating = 10,000 Amps using industry
standard 8/20 µSec wave. Surge Location Rated Category C3. UL
Recognized Component in the United States and Canada (UL1449). Type
4 Surge Protection Device. High temperature, flame retardant plastic
enclosure, 85°C maximum surface temperature rating. Thermally Protected
Transient Over-voltage Circuit.
PRODUCT SPECIFICATIONS
The Surge series of products are designed to be used in conjunction with
LED Drivers and fixtures to provide an additional level of protection
against powerline disturbances in industrial, commercial and residential
applications where surge protection to IEEE C62.41.2 is required.
SURGE PROTECTOR SPECIFICATIONS
MODEL INPUT VOLTAGE SURGE PROTECTION LEVEL MOUNTING ENCLOSURE
MATERIAL INPUT LEADS INPUT
FREQUENCY
ALS-SP 120-277V 10kV, 10kA, ANSI C62.41
Catergory C
SnapLOCK/
Footed Polycarbonate 6”, 18AWG stranded
105 Degrees C stripped 3/8” tinned 60Hz
V(in)B
Com
Black
White
Green
Ground
Surge
LOAD
LED Driver,
or Lighting
WIRING DIAGRAM
Black
1.0” 1.52”
.26”
.26”
.41”
2.91”
1.91”
1.16”
.09”
.58”
.25”
2X ø 1.14”
V(in)B
Com
Black
White
Green
Ground
Surge
LOAD
LED Driver,
or Lighting
Black
WIRING DIAGRAM
LED Lighting
ALS-SP
Common (White)
Neutral (Black)
Green (Ground)
1.0” 1.52”
.26”
.26”
.41”
2.91”
1.91”
1.16”
.09”
.58”
.25”
2X ø 1.14”
V(in)B
Com
Black
White
Green
Ground
Surge
LOAD
LED Driver,
or Lighting
Black
WIRING DIAGRAM
LED Lighting
ALS-SP
Common (White)
Neutral (Black)
Green (Ground)
CASE DIMENSIONS
1.0” 1.52”
.26”
.26”
.41”
2.91”
1.91”
1.16”
.09”
.58”
.25”
2X ø 1.14”
V(in)B
Com
Black
White
Green
Ground
Surge
LOAD
LED Driver,
or Lighting
Black
WIRING DIAGRAM
LED Lighting
ALS-SP
Common (White)
Neutral (Black)
Green (Ground)
1.0” 1.52”
.26”
.26”
.41”
2.91”
1.91”
1.16”
.09”
.58”
.25”
2X ø 1.14”
V(in)B
Com
Black
White
Green
Ground
Surge
LOAD
LED Driver,
or Lighting
Black
WIRING DIAGRAM
LED Lighting
ALS-SP
Common (White)
Neutral (Black)
Green (Ground)

CALIFORNIA ACCENT LIGHTING, INC.
2034 E. Lincoln Ave. #431, Anaheim, CA 92806
ph. 800.921.CALI (2254) or 714.535-7900 \ fx. 714.535.7902
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specications without prior notice.
Installation Instructions
LLED8700-OL
12 of 12
lipLEDs™
Maintenance & Warranty
CLEANING MATERIALS
The use of solvents and/or cleaners which are not compatible with polycarbonate will result in the softening, crazing, and/or cracking of the
plastic part. This is especially true of polycarbonate lamps and mounting bases which may be under stress in their normal applications.
COMPATIBLE WITH POLYCARBONATE:
• Mild soap and water • Mineral Spirits • Isobutyl alcohol
• VM and P Naphtha • Varsol No.2 • Mexane
• Freone TF and TE-35 • Ethanol • Dirtex
• 2% Sol. Reg. Joy • 10% Sol Bon Ami • White Kerosene
• Methyl alcohol • Heptane • Petroleum Ether/65 degrees C
• Isopropyl alcohol • Lacryl PCL-2035 polycarbonate cleaner
NOT COMPATIBLE WITH POLYCARBONATE
• Trichlor • Gasoline • ll Liquid Detergents
• Acetone • Carbon Tetrachloride • Pink Lux (Phosphate free)
• Triclene • Chlorinated Hydrocarbons •#1 & #3 denatured alcohol
• Methyl Ethyl Keytone (MEK) • Texize-8006, 8129, 8758 • MIBK
• Liquid Cleaner – 8211 • Toluol • Agitene
• Benzol • Ajax • Kleenol Plastics
• Lysol • Stanisol Naphtha • Oils
• Lemon Joy (phosphate free) • Diversol • Lestoil
WARRANTY
The manufacturer warrants this product to be free for (1) year against any defects that are due to faulty materials or workmanship. This
warranty applies only to the original consumer purchaser and only to products used in normal use and service. If this product is found to be
defective, the manufacturer’s only obligation, and your exclusive remedy, is the repair or replacement of the product at the manufacturer’s
discretion, provided that the product has not been damaged through misuse, abuse, accident, modifications, alterations, neglect, or
mishandling. This warranty shall not apply to any product that is found to have been improperly installed, set up, or used in any way not in
accordance with the instructions supplied with the product. This warranty shall not apply to a failure of the product as a result of accident,
misuse, abuse, negligence, alteration, or faulty installation or any other failure not relating to faulty workmanship. This warranty shall
not apply to the finish on any portion of the product, such as surface and/or weathering, as this is considered normal wear and tear. The
manufacturer does not warrant and specifically disclaims any warranty, whether expressed or implied, or fitness for a particular purpose,
other than the warranty contained herein. The manufacturer specifically disclaims any liability and shall not be liable for any consequential
or incidental loss or damage, including any labor/expense costs involved in the replacement or repair of said product.
This manual suits for next models
1
Table of contents
Popular Work Light manuals by other brands

UPG
UPG Flexible Lights none Specifications

Leotek
Leotek Arieta AR13 installation guide

Home Accents Holiday
Home Accents Holiday TY326-1611-1 Assembly instructions

Bright33
Bright33 B33OSL15W50BK installation instructions

ANCEL
ANCEL SQ-129 user manual

Cooper Lighting