manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MaxLite
  6. •
  7. Work Light
  8. •
  9. MaxLite 73683 User manual

MaxLite 73683 User manual

Other MaxLite Work Light manuals

MaxLite HLRS Series User manual

MaxLite

MaxLite HLRS Series User manual

MaxLite ML2LA P Series User manual

MaxLite

MaxLite ML2LA P Series User manual

Popular Work Light manuals by other brands

Conrad 77 70 78 operating instructions

Conrad

Conrad 77 70 78 operating instructions

EBS Seeberg 1 Operation manual

EBS

EBS Seeberg 1 Operation manual

Pelican 9460 user manual

Pelican

Pelican 9460 user manual

Anslut 425-080 User instructions

Anslut

Anslut 425-080 User instructions

Govee H6071 user manual

Govee

Govee H6071 user manual

LumX INSPEC LED instruction manual

LumX

LumX INSPEC LED instruction manual

LED2WORK TECLED User instructions

LED2WORK

LED2WORK TECLED User instructions

ANSMANN POWERLIGHT 5.1 operating instructions

ANSMANN

ANSMANN POWERLIGHT 5.1 operating instructions

RTRMAX RTX1868 instruction manual

RTRMAX

RTRMAX RTX1868 instruction manual

FeinTech LAL00220 quick start guide

FeinTech

FeinTech LAL00220 quick start guide

Bunker Hill Security 64735 user manual

Bunker Hill Security

Bunker Hill Security 64735 user manual

Goobay 30450 user manual

Goobay

Goobay 30450 user manual

REV Ritter SPOT Assembly and operating instructions

REV Ritter

REV Ritter SPOT Assembly and operating instructions

Ignition Stagepix Line 100 IP user manual

Ignition

Ignition Stagepix Line 100 IP user manual

SCANGRIP DUO CONNECT manual

SCANGRIP

SCANGRIP DUO CONNECT manual

Bosch GLI 18 V operating instructions

Bosch

Bosch GLI 18 V operating instructions

Bayco SL-1514 instruction manual

Bayco

Bayco SL-1514 instruction manual

EUFAB SMD LED 8+1 operating instructions

EUFAB

EUFAB SMD LED 8+1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Page : 1
REV: 6/22/2015
Operating Instructions Architectural Downlight Fixtures
MaxLite®4”, 6”, 8” and 9” LED ARCHITECTURAL DOWNLIGHT
INSTALLATION INSTRUCTIONS
General Safety Information
•To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions,
and other hazards read all warnings and instructions included with and on the fixture box and all fixture labels.
•Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
• Commercial installation, service and maintenance of luminaires should be performed by a qualified licensed electrician.
•For Residential installation: If you are unsure about the installation or maintenance of the luminaires, consult a qualified
licensed electrician and check your local electrical code.
•DO NOT INSTALL DAMAGED PRODUCT!
•This fixture is intended to be connected to a properly installed and grounded UL listed junction box.
WARNING:
•Risk of Fire - Supply conductors (power wires) connecting the fixture must be rated minimum 90℃. If uncertain consult an
electrician.
•Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaires electrical systems.
•Risk of Fire/Electric Shock - If not qualified, do not attempt installation. Contact a qualified electrician.
CAUTION:
•For your safety read and understand instructions completely before starting installation.
•To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
•Before attempting installation, check your local electrical code, as it sets the wiring standards for your locality.
NOTES:
•If luminaire (fixture) is to be switched from a wall switch, make sure black power supply wire is connected to the
switch. DO NOT connect the white supply wire to the switch.
•Make certain no bare wires are exposed outside the wire nut connectors.
•Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
Illustrations on the manual are for installation purposes only. It may not be identical to the fixture purchased.
Page : 2
REV: 6/22/2015
Operating Instructions Architectural Downlight Fixtures
MaxLite®4”, 6”, 8” and 9” LED ARCHITECTURAL DOWNLIGHT
INSTALLATION INSTRUCTIONS
INSTALLATION IN NEW CONSTRUCTION
1. Locate center of fixture opening in the ceiling sheetrock and cut a
6-1/2" diameter hole. Note: Cut a 5-1/8" (for 4" fixtures), 8-1/8" (for
8" fixtures) opening.
2. Extend hanger bars to fit between joists. Align the flange of the
hanger bar with the underside of the joists and nail the hanger bar
to the joist (Fig. 2). Level the opposite end of the hanger bar and
nail it securely to the joist. Repeat the process with the other
hanger bar.
3. Position fixture between joists at desired location by sliding
housing on hanger bars. Once the housing is in the desired
location, squeeze tabs into hanger bars to lock luminaire (fixture)
into place (Fig 2).
4.Follow steps 1 through 5 under Electrical Connections.
Figure 1.
Figure 2.
Figure 3.
Figure 4.
Page : 3
REV: 6/22/2015
Operating Instructions Architectural Downlight Fixtures
MaxLite®4”, 6”, 8” and 9” LED ARCHITECTURAL DOWNLIGHT
INSTALLATION INSTRUCTIONS
INSTALLATION IN SUSPENDED CEILINGS
1. Locate fixture proposed fixture center in the ceiling tile and cut a
6-1/2" diameter hole. Note: Cut a 5-1/8" (for 4" fixtures), 8-1/8" (for 8"
fixtures) opening.
2. Place ceiling tile in the T-bar grid.
3. Place fixture into position and snap bar hanger foot with integral
T-bar clips onto T-bars (Fig. 6).
4. Secure hanger bars to T-bars and properly support the fixture from
the building structure. Note: Optional T-Bar Clips and screws may be
used as local code authority or site conditions require (Fig. 6).
5. To secure luminaire (fixture) position in ceiling, squeeze tabs into
hanger bars to lock luminaire (fixture) into place on bars.
6. Follow steps 1 through 5 under "Electrical Connection"
ELECTRICAL CONNECTION
1. Provide electrical service according to the "National Electrical Code" or
your local electrical code to the junction box on the fixture frame.
2. Remove appropriate size knockout on fixture J-box for conduit
connector.
3. Remove J-box cover to J-box by pushing up on spring clip. Attach
Conduit with connector to J-box and secure (Fig. 7)
4. Connect supply wires to fixture wires and insulate with proper size wire
nuts (not provided).
a.) Connect incoming ground wire (green or bare) to fixture ground
wire (green or bare).
b.) Connect incoming common (white) wire to fixture common
(white).
c.) Connect incoming hot (typically black) wire to fixture black wire.
5. Replace J-box cover.
INSTALLATION INTO RECESSED HOUSING
1. Plug the female connector of the retrofit-kit onto the male connector of
the flexible conduit whip assembly. (Fig. 8)
2. Connect disconnect case (Patent pending) by snap-on fit.
3. Tuck flexible conduit whip into the housing and carefully push the
retrofit-kit into existing housing. (Fig. 9)
Figure 5.
Figure 6.
Figure 7.
Figure 8.
Figure 9.