Caltta ZXSDR R8862A S7100 User manual

ZXSDR R8862A S7100
User Manual
® Caltta Technologies. All rights reserved.

ZXSDR R8862A S7100 Product Description Internal Use Only▲
® Caltta Technologies. All rights reserved.
3
© 2020 Caltta Technologies. All rights reserved.
2020 Copyright Caltta Technologies Co.,Ltd. All rights reserved
Copyright statement:
The copyright of this document belongs to Caltta Technologies Co.,Ltd. Text contains proprietary
information owned by Caltta Technologies Co.,Ltd., without the written permission of Caltta
Technologies Co.,Ltd., any unit or individual shall not use or leak any document and pictures, this
document contains tables, picture, data and other information.
The information in this document contains the development progress of Caltta Technologies
Co.,Ltd. products and technology will continue to update, Caltta Technologies Co.,Ltd. would not
notice such information updates.
privacy statement:
Caltta Technologies Co.,Ltd. is a global leader in trunking communications and information
technology, the company is committed to protecting personal data by the use of appropriate
technical and organisational measures.
CAUTION LASER
CAUTION HOT SURFACE
CAUTION ELECTRIC SHOCK
WARNING
The RRU must be lift with handle and hole together!

ZXSDR R8862A S7100 Product Description Internal Use Only
▲
® Caltta Technologies. All rights reserved.
4
Catalog
1 Overview....................................................................................................................................................5
1.1 Introduction..................................................................................................................................... 5
1.2 Benefits............................................................................................................................................5
2 Functionality.............................................................................................................................................6
2.1 Physical Appearance.................................................................................................................... 6
2.2 Functionality................................................................................................................................... 6
3 Technical Specifications.......................................................................................................................7
4 Interface Indices......................................................................................................................................8
5 Application Scenarios........................................................................................................................... 9

ZXSDR R8862A S7100 Product Description Internal Use Only▲
® Caltta Technologies. All rights reserved.
5
1 Overview
1.1Introduction
This document provides a high level description of ZXSDR R8862A S7100
(hereinafter ZXSDR R8862A S7100), which is one new compact distributed RRU
(Remote Radio Unit) used in ZTE wireless total solution. The RRU is based on
common ZTE compacted RRU platform.and can work in LTE single mode or Multi-
Mode at the same frequency band.
1.2Benefits
2*2 MIMO Capability, Better Performance
ZXSDR R8862A S7100 is based on new compacted RRU platform and high
efficiency Power Amplifier technology. With two transmitting channels and
four receiving channels, it supports 2*2 MIMO to improve coverage, data
throughput and peak download speed.
Faster deployment
ZXSDR R8862A S7100 is 15L in volume and 17Kg in weight. It is portable to
transport and flexible to install on the pole, tower and wall, thus reducing OPEX.
Higher Efficiency, Lower TCO
ZXSDR R8862A S7100’s PA efficiency can reach up to 45% (The PA efficiency
is different based on different working frequency bands);
It supports dynamic adaptive PA power supply due to the output power, which
reduces power consumption.
It is passive thermal dissipation designed, so it is power saving and less noisy.
Integrated lightning protection unit
ZXSDR R8862A S7100 supports integrated Lightning protection unit (PIB), and
the protection level is 20 KA.

ZXSDR R8862A S7100 Product Description Internal Use Only
▲
® Caltta Technologies. All rights reserved.
6
2 Functionality
2.1Physical Appearance
ZXSDR R8862A S7100
2.2Functionality
ZXSDR R8862A S7100 is the remote radio unit of distributed base station. The
signal is transmitted /received through ZXSDR R8862A S7100 to/from base band
processing unit for further processing via standard CPRI interface.
By applying the distributed system, the feeder loss will be eliminated when the radio
unit is positioned close to the antenna. The coverage is enlarged with this solution.
The functions of ZXSDR R8862A S7100 include:
Support the LTE configuration of 1.4MHz/3MHz/5MHz/10MHz scalable
bandwidth defined in 3GPP
Band Supported: band 14
Support 2T4R in one box which can optimize spectrum efficiency greatly and
improve network uplink performance
Support 64QAM modulation in both LTE downlink and uplink
Support transmit power report function for every carrier
Support overload protection function for power amplifier

ZXSDR R8862A S7100 Product Description Internal Use Only▲
® Caltta Technologies. All rights reserved.
7
Support transmit channel switching on/off function
ZXSDR R8862A S7100 software failure will not affect the running of BBU and
other ZXSDR R8862A S7100s which are connected to it.
3 Technical Specifications
indices
ZXSDR R8862A S7100
Operation
Frequency Band
B14
Tx:758 MHz–768 MHz
Rx:788 MHz–798 MHz
Size (H*W*D) 422*218*165 mm,15L
Weight 17kg
Power
Consumption Average 210W,peak 400W
Power -48 V DC/220 V AC
Temperature -40℃~+55℃
Relative Humidity 5%RH~100%RH
Waterproof/Dustpr
oof IP65
MTBF DC:≥464,000 hours
AC:≥442,000 hours
MTTR 1 hour
Availability index DC: ≥99.999784%
AC: ≥99.999774%
Down duration DC: ≤1.133 min/year
AC: ≤1.189 min/year

ZXSDR R8862A S7100 Product Description Internal Use Only▲
® Caltta Technologies. All rights reserved. 8
4 Interface Indices
The external interfaces of the R8862A are located at the bottom and on the front side
of the chassis.
For a description of the external interfaces at the bottom of the R8862A chassis,
refer to Table 4-1.
Table 4-1 Description of the External Interfaces at the Bottom
No. Label Interface Interface Type/Connector
1 AISG/MON
AISG equipment interface
MON external monitoring
interface
LMT O&M Ethernet interface
DB15 connector
2 GND Protective grounding interface
16 mm2 yellow-green round
terminal
3ANT1
(TX/RX) TX/RX antenna interface 50 Ω DIN-mode connector
4 ANT2 (RX) RX antenna interface 50 Ω DIN-mode connector
5 ANT3 (RX) RX antenna interface 50 Ω DIN-mode connector
6ANT4
(TX/RX) TX/RX antenna interface 50 Ω DIN-mode connector
For a description of the external interfaces on the right side of the R8862A chassis,
refer to Table 4-2.
Table 4-2 Description of the External Interfaces on the Right Side
No. Label Interface Interface Type/Connector
1 OPT1
Interface for communication
between the RRU and a BBU,
or RRU cascading interface
LC-type optical interface (IEC 874)
2 OPT2 RRU cascading interface LC-type optical interface (IEC 874)
3 PWR Power input interface 2-pin customized connector

ZXSDR R8862A S7100 Product Description Internal Use Only▲
® Caltta Technologies. All rights reserved. 9
5 Application Scenarios
R8862A as the Remote Radio Unit (RRU) and Baseband Unit (BBU) comprise
distributed macro eNodeB BS8700.
Typical application scenarios of BS8700 are shown in the following figure:

FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates and can radiate
radio frequency energy. If not installed and used in accordance with the instructions, it may cause
harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. Verification of harmful interference by this equipment to
radio or television reception can be determined by turning it off and then on. The user is
encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a different circuit to that of the receiver's outlet.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Note: Any changes or modifications to this unit not expressly approved by the party responsible
for compliance could void the user's authority tooperate the equipment.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter. This equipment should be installed and operated with minimum distance 500cm
between the radiator & you body.
Table of contents
Other Caltta Radio manuals