LazerpointTM RF RX-90
Advanced Single Relay Receiver
Installation Instructions
Section 1
General Description
Camden Lazerpoint™ Radio Controls comprise the following
models:
• CM-TX-9 Wall switch ready transmitter
• CM-TX-99 Plug-in transmitter
• CM-TXLF 1, 2 & 4 button fob transmitters
• CM-RX-90 Advanced single relay receiver
• CM-RX-91 Basic single relay receiver
• CM-RX-92 Full function (dual relay) receiver.
Camden Lazerpoint™ RF is the first system designed to
address the specific needs of the Automatic Door industry.
Unlike typical “garage door” RF, Camden’s Lazerpoint™
operates at 915 MHz frequency to “cut through” the noise
and clutter, and penetrate typical building materials to ensure
a reliable installation every time.
Three receiver models are offered – the basic single relay
RX-91, the full function RX-92 and the advanced single relay
RX-90. The RX-90 offers 3 operating modes including delayed,
no delay and latched.
Camden CM-RX-90 features a convenient wiring harness,
18” in length, visual relay status, and 40 code memory with
push-and-learn technology.
Section 2
Features
• 3 Modes of Operation:
- Delayed (1 - 15 Seconds)
- No Delay (1 – 30 Seconds)
- Latching
• 40 Transmitter capacity, either delayed, non-delayed or both
• Form ‘C’ Relay Output
• 12/24V AC/DC operation
• 915 MHz Lazerpoint Technology
• Small Size: 2 5/8”H x 1 1/2”W x 13/16”D
(67mm x 38mm x 21mm)
Section 3
Installation
Mounting
The RX-90 receiver is designed to mount inside the automatic
door header. Screw holes are located at each end of the
receiver case, or the included velcro may also be used to hold
it securely.
For dimensional information refer to RX-90 electrical and
mechanical Drawing on Page 4.
Wiring
Note: Do not use the Lazerpoint RF system as a Safety
device!!. If safety devices are used, always wire them
directly to the operator control box.
Refer to the RX-90 Wiring Diagram on Page 5, and wire the
receiver as follows:
Wire the device (electric lock / operator) to the Relay output -
terminal 3 is N.O. 4 is Common, and 5 is N.C.
Connect 12 or 24 Volt AC or DC to terminals 1 & 2 on the
receiver. (The terminals are not polarity sensitive).
Page 1 of 7

Wire Description
Red Power In
Red Power In
Blue Normally Open
Grey Common
Orange Normally Closed
Section 4
Set-up Instructions
Step 1
Learning the Transmitter(s) to the Receiver
A receiver can have up to 40 transmitters paired with it. The
transmitter can be paired as delayed, non-delayed or a
combination of both, making RX-90 ideal for bi-directional
door sequencing.
Learning the Transmitter in Delayed Mode
Set SW1 to ON.
Press the PB1 button using a small blunt object such as a
small blade screwdriver or similar. Within 10 seconds, press
the switch connected to a TX-9 transmitter or a button on
a Lazerpoint FOB. The Green LED Array will flash to confirm
enrolment. Repeat with any additional transmitters. Pressing
the learned transmitter again will signal the receiver that
you are finished programming and the LED will flash rapidly.
Pressing the transmitter a third time will activate the relay
and the LED, and also the device connected to the relay
contacts after the delay time set by POT1.
If you wait longer than the 10 second period, the receiver
will time out of Learn Mode and revert back to standby.
Learning the Transmitter in No-Delay Mode
Set SW1 to OFF
Press the PB1 button using a small blunt object such as a
ON
1
POT1 SW1 PB1
ON
small blade screwdriver or similar. Within 10 seconds, press
the switch connected to a TX-9 transmitter or a button on
a Lazerpoint FOB. The Green LED Array will flash to confirm
enrolment. Repeat with any additional transmitters. Pressing
the learned transmitter again will signal the receiver that
you are finished programming and the LED will flash rapidly.
Pressing the transmitter a third time will activate the relay
and the LED, and also the device connected to the relay
contacts.
If you wait longer than the 10 second period, the receiver
will time out of Learn Mode and revert back to standby.
Step 2
Adjustments
The delay before operate and the relay On-Time are
controlled by POT1.
Delayed Mode
The RX-90 has a delay before operate timer.
Set SW1 to ON.
Adjust POT1 clockwise to increase the delay timer from 0 to
15 seconds. The LED will light and become brighter as the
delay time is increased and become dim as the delay time
is decreased. The LED starts to flash once the maximum
delay time has been reached. Back off the delay time until
the LED is solid again for maximum delay time.
No-Delay Mode
The RX-90 can be adjusted to activate the output relay
without a delay. The relay On-Time is adjustable from 1 to
30 seconds.
Set SW1 to OFF.
Adjust POT1 Clockwise/counterclockwise to adjust the relay
On-Time (1 to 30 Seconds). To increase the time, turn the
pot clockwise, or for minimum time, turn the pot counter-
clockwise. The LED will light and become brighter as the
Relay On-Time is increased. The LED starts to flash once
the maximum On-Time has been reached. Back off the POT
until the LED is solid again for maximum On-Time.
Latching Mode
The RX-90 has a latching mode. Activating the transmitter
will latch the output relay ON. Activating the transmitter a
second time will latch the Relay OFF.
SW1 can be set to either ON/OFF.
Lazerpoint™ RF RX-90 Advanced Single Relay Receiver Installation Instructions
Page 2 of 7

Adjust POT1 clockwise until the LED starts to flash. The RX-90
is in latching mode at this point. To remove latching mode,
turn POT 1 counter clockwise until the LED is solid again.
Note: Latching mode disables delayed mode. Transmitter
programmed as delayed mode will work as latching mode
transmitter.
Step 3
Deleting Transmitters
Delay Mode Transmitters
Set SW1 to ON.
Pressing and holding PB1 for 8 seconds will delete all
transmitters delay mode. The LED will flash rapidly for 4
seconds to indicate erasure of the codes.
No Delay Mode Transmitters
Set SW1 to OFF.
Pressing and holding PB1 for 8 seconds will delete all
transmitters no delay mode. The LED will flash rapidly for
4 seconds to indicate erasure of the codes.
Note that individual removal of specific codes is not possible
at this time.
Section 5
Technical Data
Model RX-90 Receiver
Size 2 5/8”H x 1 1/2”W x 13/16”D
(67mm x 38mm x 21mm)
Mounting 2 # 4 screws at 3” centers,
or Velcro (supplied)
Enclosure Clear plastic case
Operating Voltage 12 / 24 Volts, AC / DC
Current Draw 23 mA nominal @ 24 VAC
43 mA maximum @ 24 VAC
Response Time 30 – 200 ms
Memory Delay & No Delay 40 transmitters total
LED’s Indicate: relay status;
learn mode; erase mode &
potentiometer position
Output 1 x SPDT Relay contact
Rating 3 amps @ 30 VDC
Operating Time 1 – 30 seconds
Delay Time 1-15 seconds
Lazerpoint™ RF RX-90 Advanced Single Relay Receiver Installation Instructions
Page 3 of 7
Electrical Life 1 x 105minimum
Temperature Rating -40 to 185°F (-40 to +85°C)
Certifications - FCC Part 15 Compliant
- Canada RSS CNR210:1078
1032 061A
- Meets: IEC60601-1-2:2007
- Patent Pending
Section 6
Warranty
Camden Door Controls guarantees the Lazerpoint RF to be
free from manufacturing defects for 3 years from date of
sale. If during the first 3 years a Lazerpoint RF component
fails to perform correctly, it may be returned to our factory
where it will be repaired or replaced (at our discretion)
without charge. Except as stated herein, Camden extends
no warranties expressed or implied regarding function,
performance or service.
NOTE: Batteries are exempt from this warranty!

Page 4 of 7
Lazerpoint™ RF RX-90 Advanced Single Relay Receiver Installation Instructions
CX-RX-90 Electrical and Mechanincal
CAMDEN DOOR CONTROLS
SCALE: NONE
DRAWING No: FILE NAME: CM-RX-90_Mech.ai
DRAWN BY: J LEWIS DATE: 09/14/17 REVISED:
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
ON
1
POT1 SW1 PB1
25
8" [67mm]
3" [77mm]
33
8" [85mm]
13
16 [21mm]
"
11
2" [38mm]
CM-RX-90_Mech
WIRE COLOR DESCRIPTION
RED
RED
BLUE
GREY
ORANGE
POWER IN
POWER IN
NORMALLY OPEN
COMMON
NORMALLY CLOSED

Lazerpoint™ RF RX-90 Advanced Single Relay Receiver Installation Instructions
ON
1
POT1 SW1 PB1
OP TIME
LATCH
12/24V
AC/DC
POWER
NC
COM
NO
PB1
DELAY
NO DELAY
RX-90
Door Operator #1
TO OPEN
PUSH
Switch
& TX-9
CM-RX-90 Basic Wiring Diagram
CM-RX-90_Wiring_1.ai
JLEWIS 09/14/17
A
1
2
3
4
56
7
8
87654321
NEXT ASSY USED ON
APPLICATION
MATERIAL
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
DATE
NAME
TITLE:
SIZE
B
DWG. NO. REV
SCALE: 1:1
UNLESS OTHERWISE SPECIFIED:
SHEET 1 OF 1
DO NOT SCALE DRAWING
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/64
ANGULAR: MACH 0.5 BEND
TWO PLACE DECIMAL 0.010
THREE PLACE DECIMAL 0.005
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
CAMDEN DOOR CONTROLS. ANY
REPRODUCTION IN PART OR AS A
WHOLE WITHOUT THE WRITTEN
PERMISSION OF CAMDEN DOOR
CONTROLS IS PROHIBITED.
5502 Timberlea Blvd.
Mississauga, ON Canada L4W 2T7
Tel: (905) 366-3377
www.camdencontrols.com
D
C
B
A
B
C
D
12 - 24 V
AC/DC
Power
Programming Transmitters into the Receiver:
Learning the Transmitter in Delayed Mode
Step 1 - Set SW1 to ON.
Step 2 - Press the PB1 button using a small blunt object such as a small blade screwdriver or similar.
Within 10 seconds, press the switch connected to a TX-9 transmitter or a button on a
Lazerpoint FOB. The Green LED Array will ash to conrm enrolment.
Step 3 - Repeat with any additional transmitters.
Step 4 - Pressing the learned transmitter again will signal the receiver that you are nished
programming and the LED will ash rapidly. If you wait longer than the 10 second period,
the receiver will time out of Learn Mode and revert back to standby.
Learning the Transmitter in No-Delay Mode
Step 1 - Set SW1 to OFF
Step 2 - Press the PB1 button using a small blunt object such as a small blade screwdriver or similar.
Within 10 seconds, press the switch connected to a TX-9 transmitter or a button on a
Lazerpoint FOB. The Green LED Array will ash to conrm enrolment.
Step 3 - Repeat with any additional transmitters.
Step 4 - Pressing the learned transmitter again will signal the receiver that you are nished
programming and the LED will ash rapidly. If you wait longer than the 10 second period,
the receiver will time out of Learn Mode and revert back to standby.
Grey
Blue
Red
Red
Page 5 of 7

Lazerpoint™ RF RX-90 Advanced Single Relay Receiver Installation Instructions
ON
1
POT1 SW1 PB1
OP TIME
LATCH
12/24V
AC/DC
POWER
NC
COM
NO
PB1
DELAY
NO DELAY
RX-90
Door Operator #2
TO OPEN
PUSH
Switch
& TX-9
CM-RX-90 Vestibule
Wiring Diagram
CM-RX-90_Wiring_2.ai
JLEWIS 09/14/17
A
1
2
3
4
56
7
8
87654321
NEXT ASSY USED ON
APPLICATION
MATERIAL
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
DATE
NAME
TITLE:
SIZE
B
DWG. NO. REV
SCALE: 1:1
UNLESS OTHERWISE SPECIFIED:
SHEET 1 OF 1
DO NOT SCALE DRAWING
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL: 1/64
ANGULAR: MACH 0.5 BEND
TWO PLACE DECIMAL 0.010
THREE PLACE DECIMAL 0.005
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
CAMDEN DOOR CONTROLS. ANY
REPRODUCTION IN PART OR AS A
WHOLE WITHOUT THE WRITTEN
PERMISSION OF CAMDEN DOOR
CONTROLS IS PROHIBITED.
5502 Timberlea Blvd.
Mississauga, ON Canada L4W 2T7
Tel: (905) 366-3377
www.camdencontrols.com
D
C
B
A
B
C
D
12 - 24 V
AC/DC
Power
Programming the Transmitters into the Receivers:
Receiver #1
Learning Transmitter #2 into Delayed Mode
Step 1 - Set SW1 to ON (Delay Mode).
Step 2 - Press the PB1 button using a small blunt object such as a small blade screwdriver or similar.
Within 10 seconds, press switch #2 . The Green LED Array will ash to conrm enrolment.
Step 3 - Pressing switch #2 again will signal the receiver that you are nished programming
and the LED will ash rapidly. If you wait longer than the 10 second period,
the receiver will time out of Learn Mode and revert back to standby.
Step 4 - Adjust POT 1 for the delay time (1 - 15 Seconds).
Learning Transmitters #1 and #4 into No-Delay Mode
Step 1 - Set SW1 to OFF (No Delay Mode).
Step 2 - Press the PB1 button using a small blunt object such as a small blade screwdriver or similar.
Within 10 seconds, press switch #1 connected to a TX-9 transmitter or a button on a
Lazerpoint FOB. The Green LED Array will ash to conrm enrolment.
Step 3 - Repeat step #2 for switch #4.
Step 4 - Pressing the learned transmitter again will signal the receiver that you are nished
programming and the LED will ash rapidly. If you wait longer than the 10 second period,
the receiver will time out of Learn Mode and revert back to standby.
Step 5 - Adjust POT 1 for the relay Hold time (1 - 30 Seconds).
Receiver #2
Learning Transmitter #1into Delayed Mode
Step 1 - Set SW1 to ON (Delay Mode).
Step 2 - Press the PB1 button using a small blunt object such as a small blade screwdriver or similar.
Within 10 seconds, press switch #1 . The Green LED Array will ash to conrm enrolment.
Step 3 - Pressing switch #2 again will signal the receiver that you are nished programming
and the LED will ash rapidly. If you wait longer than the 10 second period,
the receiver will time out of Learn Mode and revert back to standby.
Step 4 - Adjust POT 1 for the delay time (1 - 15 Seconds).
Learning Transmitter s #2 and #3 into No-Delay Mode
Step 1 - Set SW1 to OFF (No Delay Mode).
Step 2 - Press the PB1 button using a small blunt object such as a small blade screwdriver or similar.
Within 10 seconds, press switch #2 connected to a TX-9 transmitter or a button on a
Lazerpoint FOB. The Green LED Array will ash to conrm enrolment.
Step 3 - Repeat step #2 for switch #3.
Step 4 - Pressing the learned transmitter again will signal the receiver that you are nished
programming and the LED will ash rapidly. If you wait longer than the 10 second period,
the receiver will time out of Learn Mode and revert back to standby.
Step 5 - Adjust POT 1 for the relay Hold time (1 - 30 Seconds).
ON
1
POT1 SW1 PB1
OP TIME
LATCH
12/24V
AC/DC
POWER
NC
COM
NO
PB1
DELAY
NO DELAY
RX-90
Door Operator #1
12 - 24 V
AC/DC
Power
TO OPEN
PUSH
PUSH
TO
OPEN
PUSH
TO
OPEN
Vestibule
Switches
& TX-9's
1
2
3 4
Switch
& TX-9
Receiver #1
Receiver #2
Red
Red
Blue
Grey
Red
Red
Blue
Grey
Page 6 of 7

Lazerpoint™ RF RX-90 Advanced Single Relay Receiver Installation Instructions
Page 7 of 7
5502 Timberlea Blvd.,
Mississauga, ON Canada
L4W 2T7
www.camdencontrols.com
Toll Free: 1.877.226.3369
Push Buttons Key Pads Strikes Magnetic Locks Key Switches Relays & Timers Access Control
File: Lazerpoint RF RX-90
Manual .indd Rev1
Revised: 02/10/2017
Part No.: 40-82B212
IC & FCC INFORMATION FOR USERS
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux
conditions suivantes :
1) l’appareil ne doit pas produire de brouillage;
2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
This radio receiver has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain indicated.
Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
Le présent receveur radio a été approuvé par Industrie Canada pour fonctionner avec les types d’antenne énumérés ci dessous et ayant un gain admissible
maximal. Les types d’antenne non inclus dans cette liste, et dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation
de l’émetteur.
Antenna Specication
Model: Camden Lazerpoint Proprietary PCB Antenna
Center Frequency: 915MHz
Recom. Freq. Range: 903-928MHz
Wavelength: ¼ Wave
Peak Gain: 0dBi
Impedance: 50-ohms
Connector: 2-pin Header
Oper. Temp. Range: -40° to +85°C
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there
is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
Changes or modications made to this equipment not expressly approved by Camden Door Control could void the user’s authority to operate the equipment.
Table of contents
Other CAMDEN Receiver manuals
Popular Receiver manuals by other brands

SMC Networks
SMC Networks EXW1-A11N-X1 Series instruction manual

ELEKTROBOCK
ELEKTROBOCK BPT003 operating instructions

Philips
Philips DTR220 Retuning

Extron electronics
Extron electronics Dual Link DVI Transmitter and Receiver DVI DL 201... Setup guide

Marmitek
Marmitek GIGAVIEW 545 user manual

Yamaha
Yamaha HTR-5063 Service manual