manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Camfil
  6. •
  7. Accessories
  8. •
  9. Camfil AIR IMAGE User manual

Camfil AIR IMAGE User manual

Popular Accessories manuals by other brands

Quincy lab 140AE-1 operating manual

Quincy lab

Quincy lab 140AE-1 operating manual

HomePro ZIR000 user manual

HomePro

HomePro ZIR000 user manual

DOL 20SCR Technical user guide

DOL

DOL 20SCR Technical user guide

RAB Smart Task installation manual

RAB

RAB Smart Task installation manual

Kemppi KMS 300 quick guide

Kemppi

Kemppi KMS 300 quick guide

Stearns 57,500 Series Installation and service instructions

Stearns

Stearns 57,500 Series Installation and service instructions

iGuzzini TWILIGHT COPENAGHEN manual

iGuzzini

iGuzzini TWILIGHT COPENAGHEN manual

Adelaide Annexe & Canvas Avan Deluxe installation guide

Adelaide Annexe & Canvas

Adelaide Annexe & Canvas Avan Deluxe installation guide

OHAUS 5000 instruction manual

OHAUS

OHAUS 5000 instruction manual

HOME8 WLS1300 quick start guide

HOME8

HOME8 WLS1300 quick start guide

MAXBOTIX MaxSonar quick start guide

MAXBOTIX

MAXBOTIX MaxSonar quick start guide

ioSmart iSmart56 Installation and user guide

ioSmart

ioSmart iSmart56 Installation and user guide

Focusrite Scarlett 18i8 user guide

Focusrite

Focusrite Scarlett 18i8 user guide

Velleman ED38105 user manual

Velleman

Velleman ED38105 user manual

JumpSport SkyBounce user manual

JumpSport

JumpSport SkyBounce user manual

Prima-Temp PRIYA Instructions for use

Prima-Temp

Prima-Temp PRIYA Instructions for use

Tefcold BC85I-BC85I W user manual

Tefcold

Tefcold BC85I-BC85I W user manual

Vaisala WMS302 user guide

Vaisala

Vaisala WMS302 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

INSTALL THE SIM CARD
(Only for units without pre-installed SIM card.)
Normally the SIM card is supplied with the unit, if not please do
the following:
Step 1:
Install the SIM card in the slot to the left of the power jack.
Step 2:
When these two light symbols stop blinking after about a
minute, it means that the sensor is connected to the internet.
Step 3:
Press the power button.
Step 4:
The power symbol lights up.
POWER SUPPLY
Step 1:
Choose the pin configuration suited to your region’s outlet type.
Step 2:
Slide the pin-plug into the groove of the power adapter.
Step 3:
Connect the power cord to the sensor and a power outlet.
CREATE A WEB ACCOUNT AND ADD THE SENSOR
Step 1:
Go to airimage.camfil.com
1. Log in to your account.
2. Create a new account.
Step 2:
When the sensor system is connected to the internet and you have
created an account, use your Air Image serial number and access
code to add your sensor to the account.
DESCRIPTION
FRONT
On/off
Pairing SIM card
Inlet
(Do not cover)
Power jack
Outlet
(Do not cover)
BACK
Is connected
to one or
more Air
Cleaners
Has a mobile connection
(When the bars are lit in a steady green
colour, it means that the sensor is
receiving the mobile signal.)
Is turned on
Is uploading
data to the
internet
TOP
Light symbols indicating that the sensor:
3 4
Press
Power symbol
Sensor connected to internet
Data sent from sensor to internet
www.camfil.com
Login: xxx
Password: xxx
IMPORTANT SAFETY INFORMATION
Warning! The Air Image Sensor may not be used outside or in wet
environments. Clean the sensor carefully with a dry cloth. NEVER
use pressurized air to clean the sensor.
• Do not cover the sensor
• Keep the sensor away from water, it is not waterproof
• Avoid having thick walls between the sensor and the
Air Cleaners
If the equipment is used in a manner not specified by the manu-
facturer, the equipment functionality may be impared. Always use
original power supply, recommended by Camfil.
PLEASE NOTE!
Due to electric components and local restrictions for disposal,
the sensor and its components must always be sent to a recycling
station for correct recycling.
TECHNICAL DATA
Power supply: Supplied USB Power Supply
Voltage 5 V/DC
Amps 2 A
Consumption 10 W
Operating range particles: PM1 and PM2,5
Operating range RH: 0 to 100 not condensating
Operating range temp: -10 to 50 Co
Dimensions (W x H x D): 144 x 64 x 61 mm
Weight: 200 gr
2
PAIRING THE SENSOR WITH YOUR AIR CLEANERS
Step 1:
Press the pairing button on the Air Cleaners to connect them to
the sensor system – hold the button until the LED light blinks.
Step 2:
Press the pairing button – second from the left – for 3 seconds.
Step 3:
When the Air Cleaners and the sensor are paired, the symbol with
the two linked squares will light up on top of the sensor.
Press
Air Cleaners paired with sensor
Pairing button on
Air Cleaner units
CLEAN AIR SOLUTIONS
56 1
TROUBLESHOOTING
• If the sensor is not functioning correctly or if the connection
between the sensor and the Air Cleaners is lost, restart the
sensor and repeat the steps previously described in this
brochure.
• If the sensor or the sensor system is still not working,
please contact the company where you bought the sensor
from to check the network provider coverage.
A tip:
You can hang the sensor on the wall using
these notches on the back.
CAMFIL – A GLOBAL LEADER IN AIR FILTERS
AND CLEAN AIR SOLUTIONS
Camfil is a global leader in the air filtration industry with more
than half a century of experience in developing and manufacturing
sustainable clean air solutions that protect people, processes and
the environment against harmful airborne particles, gases and
emissions.
These solutions are used globally to benefit human health,
increase performance and reduce energy consumption in a wide
range of air filtration applications.
Our 30 manufacturing plants, six R&D centres, local sales offices
and 4,500 employees provide service and support to our custom-
ers around the world.
Your login page for registration:
AIRIMAGE.CAMFIL.COM
CLEAN AIR SOLUTIONS
www.camfil.com
USER GUIDE
AIR IMAGE SENSOR
Camfil’s intelligent sensor
system for Air Cleaners
LOWER ENERGY COSTS AND INCREASED
PROTECTION OF PEOPLE AND MACHINES
Camfil’s intelligent sensor system for Air Cleaners, is a patented
Camfil technology for monitoring and controlling your indoor
air quality and energy consumption - by raising and lowering the
operating level of your Air Cleaners, depending on the amount of
particles in the air.
The system saves you energy and provides better protection of
machines and people’s health. It also provides you with an ”air
image” in the form of detailed air quality reports - easily accessed
via your dedicated page at: airimage.camfil.com
Designed by Camfil, Industrigatan 3,
SE-619 33 Trosa, Sweden
Made in Sweden