Campbell Sierra Wireless AirLink RV50 User manual

Sierra Wireless Airlink®
4G LTE Cellular Modem
For Public Static IP Addresses
Part Number #35781
Revision: 04/2021
CSL I.D - 1313
www.campbellsci.eu/rv50x
1. Introduction
NOTE:
This Quick Deploy Guide is a general reference to give the
installer an overview of the steps required to make this
system operational. The Product Manual is the definitive
source for detailed installation instructions and
information.
For best results, update to the latest data logger
operating system and version of Device Configuration
Utility.
You should have received two Quick Deploy Guides with your
RV50(X) module. The one you follow will depend on whether
your module was configured with a private dynamic or public
static IP address.
The Provisioning Report received with your Cellular Data
Service shows whether the module was configured with a
private dynamic or public static IP address. See the following
figure for an example of a Campbell Scientific Provisioning
Report. Other cellular providers should provide similar
information.
USE THIS GUIDE if your module has a public static IP address.
FIGURE 1-1. Static IP provisioning report
Additionally, Campbell Scientific cellular modules configured
with a public static IP address will have two stickers on the
module, as shown in the following figure. One sticker will show
the module phone number and data plan. The second sticker
will show the static IP address. USE THIS GUIDE.
Campbell Scientific cellular modules configured with a private
dynamic IP address will have one sticker on the module. It will
show the module phone number and data plan. USE THE
OTHER GUIDE.
FIGURE 1-2. Module with public static IP address
2. Campbell Scientific cellular data
service
Campbell Scientific can provide subscriptions to cellular
service through Verizon, AT&T, T-Mobile, Vodafone, Telstra,
and over 600 other providers worldwide. When this cellular
service is purchased with the module, the module will come
pre-provisioned with the required SIM card and APN. If you
have already purchased the RV50(X), call Campbell Scientific
to set up service.
1
3. Install the SIM card
NOTE:
If you purchased cellular service from Campbell Scientific
with the module, it will come with the SIM (Subscriber
Identity Module) card already installed.
1. Remove the SIM card cover.
2. Note the location of the notched corner for correct
alignment. The gold contact points of the SIM face
down when inserting the SIM card as shown in the
following figure. Gently slide the card into the slot until
it stops and locks into place. To eject the SIM card,
press it in slightly and release.
3. Replace the SIM card cover.
FIGURE 3-1. SIM card installation
4. Configure RV50(X)
1. Download the collection of RV50(X) configuration
templates from www.campbellsci.eu/downloads
and run the executable downloaded.
2. Connect the Cellular antenna.
3. Connect the Diversity antenna, if used. Use of a diversity
antenna is recommended, it can improve system
performance. It is required in 4G networks, but not 2G or
3G. Note: If a Diversity antenna is not used on a 2G or
3G cellular network, use ACEmanager to disable WAN/
Cellular > Network Credentials > RX Diversity.
4. Connect the power cable wires to a power supply.
Wire
ColourFunction Connect To
Black Ground G
White Enable
(On/Off)
12V or SW12V or control
port
Red Power (7 to 36
V) 12V
5. Connect the power cable to the RV50(X) DC Power
input. When the RV50(X) is properly set up and
powered, the status LEDs will turn on. The RV50(X) will
begin the activation/provisioning process and attempt
to connect to the mobile network. This process typically
takes 5 to 10 minutes. A successful connection is
indicated by a solid green or solid amber Network LED.
NOTE:
If Campbell Scientific did not provision the RV50(X)
or it does not automatically connect to the network,
you may need to to confirm or enter your APN
information. Follow steps 6 through 8 to
WAN/Cellular >SIM Slot 1 Configuration >
Network Credentials >User Entered APN.
6. Connect your Windows® computer to the RV50(X)
using the supplied Ethernet cable.
CAUTION:
Your computer may use the RV50(X) as a network
interface while connected resulting in cellular data
usage. Campbell Scientific recommends
disconnecting the computer from the RV50(X) as
soon as configuration is complete.
7. Launch a web browser, and enter
https://192.168.13.31:9443 into the address bar. The
ACEmanager login screen should appear in your
browser.
NOTE:
RV50(X)s running OS version 4.13 and older had
both HTTP port 9191 and HTTPS port 9443 enabled
by default. When using HTTP (not HTTPS) with these
older OS versions, enter the IP address using port
number 9191, for example, http://192.168.13.31:9191.
2
8. Look for a sticker on the bottom of your modem with
the manufacturer-generated default password. Log in
using User Name = user and that Password. If there is
no sticker try 12345 for the password. Make note of the
password used so it can be easily referenced when off
site. Remote access to the modem interface will require
the password.
TIP:
We strongly recommend changing the default
password to prevent unauthorized access and the
potential of malware infection. The password can
be changed from the Admin tab.
WARNING:
Failure to set a strong password in the RV50(X) may
result in misuse of the modem by malware or
hackers. Significant data overage charges may
apply.
9. Once logged in, check the Status >Home >Network
State field. It should read Network Ready, indicating the
RV50(X) is connected to the cellular network. You can
easily test the RV50(X) connection to the Internet by
selecting the Admin >Advanced tab and using the PING
tool to ping an Internet server, such as
www.campbellsci.com.
10. Click the Template button in the ACEmanager toolbar. A
template application window will appear. Browse to
and upload one of the configuration templates
downloaded from Campbell Scientific.
Template Files
Template File
Name Description
RV50_115200.xml
Default configuration with RS-232
at 115200 baud and Ethernet
communication enabled.1
RV50_9600.xml
Default configuration with RS-232
at 9600 baud and Ethernet
communication enabled.2
1CR1000X series, CR300 series, CR6 series, CR1000, CR3000,
CR800 series, CR5000, and GRANITE 6/9/10
2CR10X, CR10X-PB, CR510, CR510-PB, CR23X, CR23X-PB, and
CR200(X) series data loggers
11. Reboot the RV50(X) after successfully applying the
configuration template. You can do this by clicking the
Reboot button on the ACEmanager toolbar, by
momentarily pressing the Reset button (2 sec), or by
temporarily removing power from the RV50(X).
5. Enabling PPP mode
Launch the Device Configuration Utility . All tabs are within
the Deployment category.
On the Datalogger tab, make note of the data logger PakBus
Address (default address is 1).
On the Com Ports Settings tab, select the COMPort where the
module is connected; this is generally RS-232. Change the
Baud Rate to 115200 Fixed.
3
On the PPP tab select the Config/Port Used where the modem
is connected. This is the same as was selected on the Com Ports
Settings tab. Set Modem Dial String to ATH;AT\APPP.
Apply to save your changes.
Disconnect the Ethernet cable between the RV50(X) and
computer.
6. Set up LoggerNet
1. Select Add Root >IPPort.
2. Select PakBusPort
3. Add a data logger to the PakBusPort.
4. Select the IPPort in the Network Map. Enter the RV50(X)
IP address and port number. The IP address and port
number are input in the Internet IP Address field
separated by a colon. Preceding zeros are not entered
in the Internet IP Address (for example, 070.218.074.247
is entered as 70.218.74.247). The default port number is
6785.
5. For PakBus data loggers, leave the default settings for
the PakBusPort. PakBus Port Always Open should not be
checked. If used, enter the TCP Password.
6. For PakBus data loggers, select the data logger in the
Network Map and set the PakBus Address to match that
of the data logger (default address in the data logger is
1). If a PakBus Encryption Key was entered during data
logger setup, also enter it here. Click Apply to save the
changes.
7. Test the connection
Use the Connect screen to test the connection. Click on the
appropriate station and click Connect to initiate a call to the
data logger. The data logger must have 12 V power.
TIP:
The connection time is subject to many external factors. It
is often less than 30 seconds but could be up to 15 minutes.
Be patient.
If the connection is successful, the connectors at the bottom of
the screen will come together and clock information from the
data logger will be displayed in the Station Date/Time field.
4

Other manuals for Sierra Wireless AirLink RV50

5

This manual suits for next models

2

Popular Gateway manuals by other brands

Bosch G100 Troubleshooting

Bosch

Bosch G100 Troubleshooting

Advantech UBC-222 user manual

Advantech

Advantech UBC-222 user manual

Siemens SIMATIC S7-200 manual

Siemens

Siemens SIMATIC S7-200 manual

Dusun Roombanker S Serial user manual

Dusun

Dusun Roombanker S Serial user manual

Weinzierl KNX ENO 634 manual

Weinzierl

Weinzierl KNX ENO 634 manual

3Com 3CRWE51196 - OfficeConnect Wireless Cable/DSL... installation guide

3Com

3Com 3CRWE51196 - OfficeConnect Wireless Cable/DSL... installation guide

ZyXEL Communications ZyWALL 10 reference guide

ZyXEL Communications

ZyXEL Communications ZyWALL 10 reference guide

Controlant CO 01.01 Hardware user manual

Controlant

Controlant CO 01.01 Hardware user manual

Vantron C335 Series user manual

Vantron

Vantron C335 Series user manual

SMC Networks FieldServer FS-EZX-MOD-BAC Startup guide

SMC Networks

SMC Networks FieldServer FS-EZX-MOD-BAC Startup guide

RAKwireless WisDevice RAK72 Series installation guide

RAKwireless

RAKwireless WisDevice RAK72 Series installation guide

adept technology GadgetGateway user guide

adept technology

adept technology GadgetGateway user guide

MTX MTX-GATEWAY user guide

MTX

MTX MTX-GATEWAY user guide

Chipkin CAS 2700-15 manual

Chipkin

Chipkin CAS 2700-15 manual

RTA 460ESUS-N2E Product user guide

RTA

RTA 460ESUS-N2E Product user guide

Synway SBO500 SBO Series user manual

Synway

Synway SBO500 SBO Series user manual

PLNetworks PLG400 manual

PLNetworks

PLNetworks PLG400 manual

Kunbus Sercos Series user manual

Kunbus

Kunbus Sercos Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.