manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CANTEEN
  6. •
  7. Thermometer
  8. •
  9. CANTEEN DF673 User manual

CANTEEN DF673 User manual

Popular Thermometer manuals by other brands

Benetech GM900 instruction manual

Benetech

Benetech GM900 instruction manual

Parton PTD-400 manual

Parton

Parton PTD-400 manual

GAME 15900 owner's manual

GAME

GAME 15900 owner's manual

scigiene FP-180 instruction manual

scigiene

scigiene FP-180 instruction manual

Ametek Land UNO U1 600/1600C-L user guide

Ametek Land

Ametek Land UNO U1 600/1600C-L user guide

Delton 981A instruction manual

Delton

Delton 981A instruction manual

Taylor 5286498 instruction manual

Taylor

Taylor 5286498 instruction manual

Baker MM2P instruction manual

Baker

Baker MM2P instruction manual

Chino IR-FA Series instructions

Chino

Chino IR-FA Series instructions

Vive DMD1010 user manual

Vive

Vive DMD1010 user manual

Tarmo 320281 manual

Tarmo

Tarmo 320281 manual

Citizen CTD 504 instruction manual

Citizen

Citizen CTD 504 instruction manual

TFA 14.1500 instruction manual

TFA

TFA 14.1500 instruction manual

Gotemp THB4002 user guide

Gotemp

Gotemp THB4002 user guide

GREISINGER G 1202 Quick reference guide

GREISINGER

GREISINGER G 1202 Quick reference guide

Amprobe TMD-53W user manual

Amprobe

Amprobe TMD-53W user manual

Trotec BP10 operating manual

Trotec

Trotec BP10 operating manual

Radiance instruments RT616 Series product manual

Radiance instruments

Radiance instruments RT616 Series product manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Model:
DF673
Mini Infrared
Thermometer
Instruction manual
DF673_UK_A5_v1_180110.indb 1 2018/1/10 18:17
2
UK Telephone Helpline: 0845 146 2887
Function Diagram
A. LCD display
B. °C/°F unit selector button
C. Laser hole
D. Trigger
E. Battery compartment cover
A
B
C
D
E
1
2
3
4
5
67
1. Battery power icon
2. Scan lock
3. Backlight indicator
4. °C / °F
5. Current temperature reading
6. The maximum display
7. The maximum state
Operation
1. Remove the battery compartment cover. Install the batteries and replace the cover.
2. Press the trigger to turn on.
3. Aim at target and press the trigger for 1 second. Temperature reading will show once trigger is released.
4. To select between °C and °F, use selector button (°C/°F) on front of thermometer.
5. Thermometer will automatically turn off after being idle for 30 seconds.
Specifications
• Temperature range: -50°C to 520°C (-58°F to 968°F)
• Temperature Resolution: 0.1°C (0.2°F)
• Accuracy: ±2%
• Laser Wavelength: 635~650um, power ≤ 1mw
• Ideal Ambient Conditions for use:
0°C ~ 40°C, humidity ≤ 85%
• Storage Temperature: ≤ 60°C
• Power: 2x 1.5V (AAA battery)
Distance to Spot Ratio (12:1)
DF673_UK_A5_v1_180110.indb 2 2018/1/10 18:17
3
UK
Telephone Helpline: 0845 146 2887
Cleaning, Care and Maintenance
• Lens cleaning – remove loose particles using clean compressed air, gently brush remaining debris
away using soft clean brush.
• Clean the case with a damp cloth and warm water.
• DO NOT USE SOLVENTS TO CLEAN LENS.
• DO NOT SUBMERGE THERMOMETER IN WATER.
• AVOID ELECTRMAGNETIC FIELDS SUCH AS INDUCTION COOKERS.
• DO NOT POINT LASER DIRECTLY OR INDIRECTLY TOWARDS EYE.
All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic,
mechanical, photocopying, recording or otherwise, without the prior written permission of CANTEEN.
Every effort is made to ensure all details are correct at the time of going to press, however, CANTEEN reserve the right to
change specifications without notice.
DF673_UK_A5_v1_180110.indb 3 2018/1/10 18:17
DF673_UK_A5_v1_180110
DECLARATION OF CONFORMITY
•Conformiteitsverklaring • Declaration de conformite • Konformitatserklarung • Dichiarazione di conformita •
• Declaraci6n de conformidad • Declarac;ao de conformidade
Equipment Type • Uitrustingstype • Type d'equipement •
Geratetyp •
Tipo di apparecchiatura • Tipo de equipo • Tipo de equipamento
Model • Modele • Modell • Modello • Modelo • Malli
Application of Council Directives(s)
Toepassing van Europese Richtlijn(en) • Application de la/des
directive(s) du Conseil • Anwendbare EU-Richtlinie(n) •
Applicazione delle Direttive • Aplicaci6n de la(s) directiva(s) del
consejo • Aplica ao de directiva(s) do Conselho
Producer Name • Naam fabrikant • Norn du producteur • Name
des Herstellers • Nome del produttore • Nombre del fabricante •
Nome do fabricante
Producer Address • Adres fabrikant • Adresse du producteur •
Anschrift des Herstellers • lndirizzo del produttore • Direcci6n
del fabricante • Endere o do fabricante
Mini lnfrared Thermometer
DF673
General Product safety Directive
EN 60525-1 :2014
Electro-Magnetic Compatibility (EMC) Directive
2014/30/EU
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 61326-1:2013
EN 61000-4-2:2009
EN 61000-4-3:2006 +A1:2008 +A2:2010
EN 61000-4-4:2012
EN 61000-4-5:2014
EN 61000-4-6:2014
EN 61000-4-8:2010
EN61000-4-11 :2004
Restriction of Hazardous Substances Directive
(RoHS) 2011/65/EU
Canteen
Fourth Way,
Avon mouth,
Bristol,
BS11 8TB
United Kingdom
I,
the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
lk, de ondergetekende, verklaar hierbij dat de hierboven gespecificeerde uitrusting goedgekeurd is volgens de bovenstaande
Richtlijn(en) en Standaard(en).
Je soussigne, confirme la conformite de l'equipement cite dans la presente
a
la/ aux Directive(s) et Norme(s) ci-dessus
lch, der/die Unterzeichnende, erklare hiermit, dass das oben angegebene Gerat der/den oben angefuhrten Richtlinie(n) und Norm(en)
entspricht.
II sottoscritto dichiara che l'apparecchiatura di sopra specificata
e
conforme alle Direttive e agli Standard sopra riportati.
El abajo firmante declara por la presente que el equipo arriba especificado esta en conformidad con la(s) directiva(s) y estandar(es)
arriba mencionadas.
Eu, o abaixo-assinado, declaro que o equipamento anteriormente especificado esta em conformidade corn a(s) anterior(es) Directiva(s)
e Norma(s)
Date • Data • Date • Datum • Data • Fecha • Data
Signature • Handtekening • Signature • Unterschrift
Firma • Firma • Assinatura
Full Name • Volledige naam • Norn et prenom • Vollstandiger Name •
Nome completo • Nombre completo • Nome par extenso
Position • Functie • Fonction • Position • Qualifica • Posici6n • Fun ao
20
th
June 2017
Technical & Quality Manager
Ashley Hooper
DF673_UK_A5_v1_180110.indb 4 2018/1/10 18:17