Trotec BP10 User manual

EN Operating manual - Infrared thermometer BP10 B - 1
Notes regarding the operating manual............ B - 01
Safety............................................................. B - 03
Technical data................................................ B - 05
Description of the device ................................ B - 06
Operation ....................................................... B - 08
Maintenance and repair.................................. B - 13
Disposal ......................................................... B - 14
Declaration of conformity................................ B - 15
Symbols
Danger!
Warns of a hazard which can lead to inju-
ries.
Risk from laser radiation!
Warns of injury risk from laser radiation.
Caution!
Warns of a hazard which can lead to
damage to property.
Table of contents Notes regarding the operating manual

B - 2 Operating manual - Infrared thermometer BP10 EN
Legal notice
This release replaces all previous versions. No part of
this publication may be reproduced without written per-
mission from TROTEC®. The same applies for electro-
nically processing, duplicating or spreading the
publication. Subject to technical changes. All rights
reserved. Trademarks are used without guarantee that
they may be used freely and primarily following the
spelling of the manufacturer. Product names are registe-
red.
Changes to construction in the interests of constant
improvements to the product, as well as changes to the
shape and colour are reserved.
The delivered product may vary from product images.
This document was created with all due care. TROTEC®
accepts no liability whatsoever for possible mistakes or
omissions. © TROTEC®

EN Operating manual - Infrared thermometer BP10 B - 3
Intended use
This device is exclusively intended for measuring tem-
perature with an infrared sensor in the measuring range
specified in the technical data. People who use this de-
vice must have read and understood the operating ma-
nual, especially the "Safety" chapter.
Improper use
The device must not be used in potentially explosive at-
mospheres. It may not be pointed at people.
TROTEC® accepts no liability for damages resulting from
improper use. In such a case, entitlements to a warranty
are forfeited.
Safety

B - 4 Operating manual - Infrared thermometer BP10 EN
Risk from laser radiation!
• Do not look into the laser beam. Do not point the
device at people.
Danger!
• Keep a sufficient distance away from sources of heat!
Caution!
• Do not use abrasive cleaners or solvents to clean the
device.
• Do not leave the packaging lying around. Children
may use it as a dangerous toy.
• The device is not a toy and does not belong in the
hands of children.

EN Operating manual - Infrared thermometer BP10 B - 5
Model BP10
Weight 82 g
Dimensions H x W x D 96 x 57 x 25 mm
Measuring range -30 °C to 270 °C / -22 °F to 518 °F
Accuracy ± 2 °C (± 4 °F) or 2.0 % of the measured
value (the higher value applies)
Measuring range resolution 0.1 °C / °F
Operating temperature 0 °C to 50 °C (32 °F to 122 °F)
Humidity during operation Max. 80 % relative humidity
Laser output < 1 mW (630–670 nm)
Laser class ll
Emissivity Adjustable between 0.10 and 1.0
Technical data Distance to measuring spot
ratio
6:1
Reaction time < 1 second
Power supply two 1.5 V AAA batteries
Switch off After approx. 10 seconds of non-use

B - 6 Operating manual - Infrared thermometer BP10 EN
Functional description
The infrared thermometer BP10 uses an infrared sensor
to measure surface temperatures without contact. So
that you can accurately see where the device is measu-
ring, a built in laser pointer can be switched on. The de-
vice can show either the highest or lowest value of the
measurement. For the maximum or minimum value, a
temperature alarm can also be set.
Description of the device
1. IR sensor 2. "Meas" button
3. "Set" button 4. Display
5. "Laser" button 6. Laser pointer
2
1
3
4
5
6

EN Operating manual - Infrared thermometer BP10 B - 7
Display 7. Maximum value alarm on
8. Temperature alarm on
9. Emissivity
10. Unit of the temperature
11. Temperature display
12. Battery indicator
13. Change the values up/down
14. Shows the maximum or minimum value
15. Measurement is on
16. Display is frozen
17. Laser pointer on
18. Continuous measurement on
10
9
11
78
13
14
15 16 17 18
12

B - 8 Operating manual - Infrared thermometer BP10 EN
Temperature measurement
• Ensure that the surface to be measured is free of
dust, dirt or similar substances.
• To be able to gain exact measurement results on sur-
faces which reflect heavily, stick matt masking tape
to the surface or apply matt black paint with a very
high and known level of emissivity.
• Note the 6:1 ratio of the distance to the measuring
spot size. The larger the distance to the object, the
larger the measuring spot size and hence, the less
precise the measured result.
Operation
24:412:26:1
600:100300:50150:25
inch
mm

EN Operating manual - Infrared thermometer BP10 B - 9
1. Point the device at the object to be measured and
hold down the "MEAS" (2) button.
–The device turns on and carries out a measu-
rement. The "SCAN" symbol (15) appears in the
display. The current measured value is shown.
2. Release the "MEAS" button (2).
– The device stops measuring. The "HOLD"
symbol (16) appears in the display. Depending on
the setting of the device, either the maximum or
minimum value of the last measurement is shown.
The device switches off after approx. 10 seconds without
being used.
Settings
Laser pointer / display backlight
• Press the "Laser" button (5) once to switch on the
laser pointer. The "Laser pointer on" symbol (17)
appears on the display.
• Press the "Laser" button (5) twice to switch on the
display backlight.
• Press the "Laser" button (5) three times to switch off
the laser pointer.
• Press the "Laser" button (5) four times to switch off
the display backlight.

B - 10 Operating manual - Infrared thermometer BP10 EN
Temperature measurement settings
With the "Set" button (3), you can switch between the
settings for temperature measurement. The order is the
same as in the following description. Confirm the entries
with the "MEAS" button (2).
Changing the display - Minimum/Maximum
The "Max" symbol (14) is shown. Press the "Laser"
button (5) to change between Min and Max.
Changing the display °C - °F
The "°C" and "°F" symbols (10) flash. Press the "Laser"
button (5) to change between the units for the measured
values.

EN Operating manual - Infrared thermometer BP10 B - 11
Increase emissivity
The "Emissivity" symbol (9) flashes.
An arrow (13) is shown.
Press the "Laser" button (5) to increase emissivity.
Decrease emissivity
The "Emissivity" symbol (9) flashes.
An arrow (13) is shown.
Press the "Laser" button (5) to decrease emissivity.
Continuous measurement
The "Continuous measurement on" symbol (18) is
shown.
The "Off" message appears in the display.
Press the "Laser" button (5) to switch on continuous me-
asurement.
The "On" message appears in the display.
In continuous measurement mode, the device stays
running until the "Laser" button (3) is pressed again.

B - 12 Operating manual - Infrared thermometer BP10 EN
Increase temperature alarm
The "HI" symbol (7) is shown.
An arrow (13) is shown.
Press the "Laser" button (5) to increase the highest
value.
Decrease temperature alarm
The "HI" symbol (7) is shown.
An arrow (13) is shown.
Press the "Laser" button (5) to decrease the maximum
value.
Temperature alarm on/off
The "Temperature alarm" symbol (8) appears.
The "Off" message appears in the display.
Press the "Laser" button (5) to switch on the tempera-
ture alarm.
The "On" message appears in the display.
Press the "Laser" button (5) again to switch off the tem-
perature alarm.
The "Off" message appears in the display.

EN Operating manual - Infrared thermometer BP10 B - 13
Battery change
Caution!
Make certain that the surface of the device
is dry and the device is switched off.
Maintenance and repair

B - 14 Operating manual - Infrared thermometer BP10 EN
Cleaning
Clean the device with a soft, damp and lint-free cloth.
Ensure that no moisture enters the housing. Do not use
any sprays, solvents, alcohol-based cleaning agents or
abrasive cleaners. Only use clean water to moisten the
cloth.
Repair
Do not modify the device or install any spare parts. For
repairs or device testing, contact the manufacturer.
In the European Union, electronic equip-
ment must not be treated as domestic was-
te, but must be disposed of professionally
in accordance with Directive 2002/96/EC of
the European Parliament and Council of 27th January
2003 concerning old electrical and electronic equip-
ment. After the end of its use, please dispose of this de-
vice in a manner appropriate to the relevant legal
requirements.
Disposal

EN Operating manual - Infrared thermometer BP10 B - 15
in accordance with the EC Low Voltage Directive
2006/95/EC, Annex III, Section B and the EC Directive
2004/108/EC about electromagnetic compatibility. We
hereby declare that the infrared thermometer BP10 was
designed, developed and produced in compliance with
the named EC Directive.
Manufacturer:
Trotec GmbH & Co. KG Phone: +49 2452 962-400
Grebbener Straße 7 Fax: +49 2452 962-200
D-52525 Heinsberg E-mail: info@trotec.com
Heinsberg, 5 April 2012
Managing Director: Detlef von der Lieck
Declaration of conformity

TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg
Tel.: +49 2452 962-400 • Fax: +49 2452 962-200
www.trotec.com • E-Mail: info@trotec.com
Other manuals for BP10
1
Table of contents
Other Trotec Thermometer manuals