Foreword...................................................................................... 3
Safety........................................................................................... 3
General safety.......................................................................... 3
Notes and symbols used.......................................................... 3
Personnel qualifications............................................................4
Intended use.............................................................................5
Reasonably foreseeable misuse.............................................. 5
General description...................................................................... 6
Assembly......................................................................................6
Recommended screw types..................................................... 7
Maximum dimensions of the screws........................................ 8
Operation......................................................................................8
Configuring CANEO series41 with IO-Link...............................8
Maintenance.................................................................................8
Maintenance operations........................................................... 8
Disassembly................................................................................. 9
Disposal........................................................................................9
Technical specifications................................................................9
Technical specifications............................................................ 9
Connection options................................................................. 10
Connection plan......................................................................11
Drilling pattern.........................................................................13
Dimensional drawing.............................................................. 14
Technical specifications.......................................................... 15
Manual updates..........................................................................15
Imprint.........................................................................................15
Product description / Product description.................................. 16

Foreword
These operating instructions are intended for technicians/installers
and operators and should be kept for future reference. Read these
operating instructions carefully and make sure that you have
fully understood the contents before installing or working with the
SENSORswitches.
TIP
Metric and imperial measurements are used in drawings.
Imperial measurements are marked with [ ].
Safety
General safety
All work on electrical systems or operating equipment may only
be carried out by a specially qualified electrician according to the
applicable electrotechnical regulations.
The safety of the system in which the SENSORswitch is integrated
is the responsibility of the operator.
Notes and symbols used
Warning notes in relation to personal injury / material damage are
formulated according to the "SAFE” principle. This means they
contain information on the type and source of the hazard, potential
consequences as well as how to avoid and avert danger. The
following hazard classifications apply in the safety notes:
DANGER
Danger designates a hazardous situation, which,
if ignored, will lead to death or serious injury. The
symbol next to the warning indicates the type
and source of the danger.
en

WARNING
Warning designates a hazardous situation,
which, if ignored, may lead to death or serious
injury. The symbol next to the warning indicates
the type and source of the danger.
CAUTION
Caution designates a hazardous situation, which,
if ignored, may lead to injury. The symbol next to
the warning indicates the type and source of the
danger.
NOTICE
Notice designates a situation, which may cause material
damages and impair the product’s function if attention is not
paid.
TIP
Tip provides additional useful information about the handling of
the product.
Symbol Meaning
4Avoiding and adverting danger in the warning note
►Instructions for action
All instructions to be followed within a procedure are
always listed in chronological order.
■List
Personnel qualifications
A qualified electrician is a person with suitable technical training,
expertise and experience as well as knowledge of relevant

standards, who can evaluate the work assigned to them
correspondingly and recognize potential risks.
WARNING
Improper work on electrical systems!
Electric shock can result in death or life-
threatening injuries.
4Before working on electrical systems,
disconnect them from their voltage supply
and secure them against being switched on
again.
4Work on electrical installations should be
carried out only by qualified personnel in
compliance with local and national electrical
regulations and specifications.
Intended use
series41 is suitable for a variety of applications. Different operating
states can be displayed with the LED outer ring. The optional four-
digit seven-segment display can show numbers from 1 - 9999 and,
to a limited extent, combinations of letters. series41 is intended for
use in accordance with the items listed here, the values from the
“Technical specifications” chapter and the values from the product
description.
■Only connect the product to a limited energy source as per IEC
61010 or to an NEC class 2 power supply unit.
■Source current < 4 A at maximum operating voltage.
Reasonably foreseeable misuse
Any use other than as specified in the section Intended use or
extending beyond this is deemed to be improper.
The SENSORswitch is not suitable for:
■use in potentially explosive atmospheres.
■use as a safety component as per directive 2006/42/EC
en

General description
The supplied SENSORswitch can have options that differ from
those shown in this manual. This does not affect the function. The
SENSORswitch is equipped with different color LEDs to indicate
operating conditions. The LEDs are actuated differently depending
on the pin configuration.
A Colored cover ring
B Sensor element with symbol
or four-digit seven-segment
display
C Drill holes for fastening. see
Chapter , "Recommended
screw types"
D 5-pin M12 connection on the
back
E Mounting flange with sensor
element
Assembly
WARNING
Improper work on electrical systems!
Electric shock can result in death or life-
threatening injuries.
4Before working on electrical systems,
disconnect them from their voltage supply
and secure them against being switched on
again.
4Work on electrical installations should be
carried out only by qualified personnel in
compliance with local and national electrical
regulations and specifications.

Requirements: Mounting surface
is level and clean (maximum
unevenness of the mounting
flange 0.1 mm).
► Disconnect the system from its voltage supply and secure it
against being switched on again.
► Set the desired position of the SENSORswitch and drill a hole
with a diameter of 25 mm .
► Position mounting flange (B), lining up the center and vertical
axis, and mark the holes (C).
Select and drill the diameter of the holes according to the
recommended screw type see "Recommended screw types",
page 7.
► Select the diameter to match the mounting surface and screw
type.
► Align mounting flange with sensor element (B) and tighten with
screw.
► Place colored cover ring (A) with groove downward and press
close to the button surface.
► Connect SENSORswitch with M12 connection (E).
NOTICE
Mineral grease and oils can attack the plastic of the button!
4Do not use grease or oils to apply the cover ring (A).
Recommended screw types
■DIN EN ISO 1207 M4
■DIN EN ISO 7045 M4
en

■DIN EN ISO 1481 Ø3.9 mm
■DIN EN ISO 7049 Ø3.9 mm
Maximum dimensions of the screws
The drawing shows the
maximum dimensions of the
screws.
Operation
series41 is operated by touching the button surface.
Configuring CANEO series41 with IO-Link
TIP
For information on configuring the
SENSORswitch, see our website
series4x or scan the QR code.
Maintenance
Maintenance operations
Carry out the following maintenance operations at the specified
intervals.
Maintenance operation as needed annually
Clean the button surface X
Check cables for intactness and firm
fit
X
Check screw connections for
tightness
X

NOTICE
Solvents contained in cleaning agents can attack the
plastic of the button!
4Clean the surface of the button with a neutral cleaning agent
or a damp microfiber cloth.
Disassembly
► Disconnect the system from its voltage supply and secure it
against being switched on again.
► Insert the flat head screwdriver into the groove (D) on the cover
ring (A) and remove the cover ring with the screwdriver via lever
action.
► Loosen the screw connections and disconnect the electrical
connection.
Disposal
Different types of electrical and electronic components must be
recycled according to their type. All applicable statutory, state and
local laws and regulations must be complied with.
Technical specifications
Technical specifications
series4x
Operating voltage DC 12 - 24 V (8.4 to 31.2 V)
Load current max. 200 mA
Reverse polarity protection Protection of all cables/lines
Short circuit protection Protected against short circuit and overload
Voltage drop Max. 2.5 V at 200 mA load current
Power consumption at 24 V Max. 90 mA
Operating temperature -25°C (-13°F) to 50°C (122°F)
Degree of protection IP Front IP69K Maximum unevenness in mounting
surface < 0.2 mm
Degree of protection IK IK08
Communication interface IO-Link specification V1.1
en

series4x
Measuring principle Capacitive
Type of actuation Touch
Actuation force No actuation force required
max. altitude 3000 m above standard zero
Relative air humidity Max. 95%, non-condensing
Connection options
Plug M12, 3-pin
N/A
N/A
Plug M12, 4-pin
N/A
Plug M12, 5-pin

Connection plan
3-pin
OUT
IO - Link Communication
(NPN / PNP NO / NC)
0V
+VDC
3
4
2
5
1
brown
black
blue
The product description will indicate the configuration.
4-pin
E1
0V
+VDC
3
4
2
5
1
brown
white
black
blue
OUT
IO - Link Communication
(NPN / PNP NO / NC)
The product description will indicate the configuration.
en

5-pin
E1
E2
0V
+VDC
3
4
2
5
1
brown
white
gray
black
blue
OUT
IO-Link communication
(NPN / PNP NO / NC)
The product description will indicate the configuration.

Drilling pattern
Metric and imperial measurements are used in drawings. Imperial
measurements are marked with [ ].
en

Dimensional drawing
63,15
2,486
99,80
3,929
27,46
1,081
17,46
0,687
9,60
0,378
Metric and imperial measurements are used in drawings. Imperial
measurements are marked with [ ].

Technical specifications
Manual updates
CAPTRON reserves the right to make changes to the contents of
this manual as needed. The most current version can be found on
our website www.captron.com .
Imprint
The operating instructions have been authored and published by
CAPTRON Electronic GmbH
Johann-G.-Gutenberg-Straße 7
82140 Olching – Germany
Tel +49 (0) 8142 44 88 – 160
www.captron.com
Copyright 2021