manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cardinal Components
  6. •
  7. Control Unit
  8. •
  9. Cardinal Components ElectroSet CB-035 User manual

Cardinal Components ElectroSet CB-035 User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1of10 rev.1.01
ElectroSet™
7 Segment LED Module CB-035
Overview
The CB-035 device is an, 8-digit 7-segment display.
Each segment can be individually addressed and updated separately using a 2 wire I²C
interface. Only one external resistor (RSET) is required to set the current. LED brightness
can be controlled by analog or digital means.
The device include an integrated BCD code-B/HEX decoder, multiplex scan circuitry,
segment and display drivers, and a 64-bit memory. Internal memory stores the shift
register settings, eliminating the need for continuous device reprogramming.
Features
• 7 Segment Display
• 8 Digit LED Module
• Up to 1MHZ I²C Compatible
Interface
• Individual LED Segment Control
• Hexadecimal for 7-Segment Displays
• 200 nA Low-Power Shutdown
Current (type; data retained)
• Digital and Analog Brightness
Control
• Display Blanked on Power-Up
Basic Parameters
•
Single Voltage Supply:3.3V
• Communication: I²C compatible connection
• Default Address:0x00
145Rt.46West
Wayne,NJ07470
Tel:(973) 689-9960
E‐mail:sales@electro‐set.net
Web:www.Electro‐set.net
2of10 rev.1.01
ElectroSet™
Example Applications
• Device Display
• Electronic meters
• Digital clocks
• IOT
• Machine Data
• H
obby
i
st/
Di
Y
Functional Block Diagram
145Rt.46West
Wayne,NJ07470
Tel:(973) 689-9960
E‐mail:sales@electro‐set.net
Web:www.Electro‐set.net
3of10 rev.1.01
ElectroSet™
Configuration
• The I²Cserial method requires only two pins for communication– SDA (serial
data) and SCL (serial clock).
• The default slave address is factory-set to 0000000.
•The Last bit of the address byte (R/W) define the operation to be
performed. When set to a 1 a read operation is selected, when set
to a 0 a write operation is selected.
Board Connection Schematic
145Rt.46West
Wayne,NJ07470
Tel:(973) 689-9960
E‐mail:sales@electro‐set.net
Web:www.Electro‐set.net
4of10 rev.1.01
X2X2
DS7DS6DS5DS4DS3DS2DS1DS0
X1
Vdd
Gnd
SDA
SCL
ElectroSet™
Gnd
Vdd
SDA
SCL
X1
145Rt.46West
Wayne,NJ07470
Tel:(973) 689-9960
E‐mail:sales@electro‐set.net
Web:www.Electro‐set.net
5of10 rev.1.01
SeeTable9
SeeTable8
SeeTable10
SeeTable10
SeeTable10
SeeTable10
SeeTable5
SeeTable6
SeeTable7
SeeTable4
000
000
000
DigitandControlRegisters
DigetRegister
Address
Digit0
Digit1
Digit2
Digit3
Digit4
Digit5
Digit6
0
0
0
0
ElectroSet™
D15:D13 D12 D11 D10 D9 D8 D7:D0
Register
Type
0
000
000
000
000
0
0
0
0
00
1
0
0
0
1
1
1
1
00
01
0
0
0
0
1
000
0
0
1
0
1
0
0
000
01
10
DIG2:DIG3Intensity
DIG4:DIG5Intensity
DIG6:DIG7Intensity
1
1
0Digit7
0
0
0
See
Table1
Table2
Table3
ControlRegister
DecodeMode
GlobalIntensity
ScanLimit
Shutdown
SelfAddressing
Feature
DisplayTestMode
DIG0:DIG1Intensity
1
1
1
001
000
000
000
000
0
1
1
0
1
0
0
0
1
1
0
0
0
000
0
0
0
0
1
1
1
1
0
000
000
000
000
1
0
1
1
0
1
1
0
0
0
1
0
1
1
0
1
0
1
1
1
1
1
0
1
0
145Rt.46West
Wayne,NJ07470
Tel:(973) 689-9960
E‐mail:sales@electro‐set.net
Web:www.Electro‐set.net
6of10 rev.1.01
D7 D3 D2 D1 D0 D7 D3 D2 D1 D0 D7 D3 D2 D1 D0
D7 D3 D2 D1 D0 D7 D3 D2 D1 D0 D7 D3 D2 D1 D0
D1 D0
DP A B C D E F GCorrespongingSegmentLine
D7 D6 D5 D4 D3 D2
ThedecimalpointcanbeenabledwitheverycharacterbysettingbitD7=1
Table3
NoDecodeMode.DatabitsandCorrespondingSegmentLine
s
1
1
ThedecimalpointcanbeenabledwitheverycharacterbysettingbitD7=1
D6:D4
RegisterData Char‐
acter
RegisterData
D6:D4
ElectroSet™
0
1
2
3
4
5
Char‐
acter
X
1
1
0
8
9
01
7
6
Char‐
acter
RegisterData
D6:D4
H
L
00
0
0
0
0
X
0
0
0
0
0
0
0
-
X
X
X
X
X
X
X
X
0
0
1
1
1
1
1
0
0
1
0
1
00
0
1
0
X
0
1
1
0
0
1
1
P
1
11
11
1
0
1
1
X
.
X
X
X
X
10
1111
1
1E
0
1X1
X
X
0
0
RegisterData
D6:D4
0
0
XX
Char‐
acter
RegisterData Char‐
acter
RegisterData
D6:D4 D6:D4
Char‐
acter
0X0
X01
00 6X 110
1X 0001
0
1001
1
2X 0010 8
00
1
X 100
7
100 A4 X0
X
3X11
9
11
X10
X10
10
5X 0101 b
0
dX 1101
C
X11
0X11
10
FX 1111
E
X
Table2
Table1
HEXFont
Code‐BFont
.X XXX
145Rt.46West
Wayne,NJ07470
Tel:(973) 689-9960
E‐mail:sales@electro‐set.net
Web:www.Electro‐set.net
7of10 rev.1.01
D7 D6 D5 D4 D3 D2 D1 D0
00000000
00000001
00000111
00111111
D2 D1 D2 D1
00 00
00 00
01 01
01 01
10 10
10 10
11 11
11 11
D2 D1 D0 D2 D1 D0
000 100
001 101
010 110
011 111
Displaydigits0:7 0xX7 X
Displaydigits0:5 0xX5 X
Displaydigits0:6 0xX6 X
X
X
X
X
Displaydigits0:1
Displaydigits0:2
Displaydigits0:3
0xX1
0xX2
0xX3
RegisterData
D7:D3
DisplaydigitS0:4 0xX4 X
Table6
Scan‐LimitRegister(0x0B)
ScanLimit
Displaydigit0only
HEX
CODE
0xX0
RegisterData
D7:D3 ScanLimit HEX
CODE
16/16(maxon) 0xXF 1 1
15/16 0xXE 1 0
14/16 0xXD 1 1
13/16 0xXC 1 0
12/16 0xXB 1 1
11/16 0xXA 1 0
0
0
0
1
0
1
0
1
0
1
0
0
0
0
7/16
8/16
0xX1
0xX2
0xX3
0xX4
0xX5
0xX6
0xX7
3/16
4/16
5/16
6/16
0xX8 1 0
2/16 0 10/16 0xX9 1 1
1/16(minon) 0xX0 0
DutyCycle
9/16
IntensityControlRegister(0x0A)
DutyCycle HexCode MSB LSB HexCode MSB LSB
101
Table5
0100
CodeB/Hexdecodefrodigit0:5,Nodecodefordigits7:6
CodeB/Hexdecodefordigits0,2,5
NoDecodefordi
g
its1,3,4,6,7
HexCode RegisterData
0x00
0x01
0x07
0x3F
0x25 0
CodeB/Hexdecodefrodigit0,Nodecodefordigits7:1
Nodecodefordigits7:0
DecodeMode
CodeB/Hexdecodefrodigit0:2,Nodecodefordigits7:3
Table4
DecodeEnableRegisterFormatExamples
ElectroSet™
145Rt.46West
Wayne,NJ07470
Tel:(973) 689-9960
E‐mail:sales@electro‐set.net
Web:www.Electro‐set.net
8of10 rev.1.01
D7 D6 D5 D4 D3 D2 D1 D0
1XXXXXX0
1XXXXXX1
StartBlinkingwithdisplayenabledphase.WhenbitD4(blink_en)
isset,bitD7determineshowblinkingstarts.
0=Blinkingstartswiththedisplayturnedoff.
1=Blinkingstartswiththedisplayturnedon.
D7 blink_
start 0 R/W
D3
D4
D5
D6
R/W
R/W
NotUsed
Enablesblinking.
0=Disableblinkin
g
.1=Enableblinkin
g
Sets
bl
in
k
wit
h

l
ow
f
requency
(
interna
l
osci
ll
atorena
bl
e
d)
:
0=Blinkperiodtypicallyis1second(0.5son,0.5soff)
1=Blink
p
eriodis2seconds
(
1son1soff
)
Sync
h
ronizes
bl
in
k
ingont
h
erisinge
d
geo
f
pinLD
/
CS.T
h
e
multiplexandblinktimingcounterisclearedontherisingedge
of
p
inLD
/
CS.Setthisbitformulti
p
ledevicestos
y
ncalldevices.
blink_en 0 R/W
R/W
ResetsallcontrolregistersexcepttheFeatureRegister.
0=ResetDisabled.Normaloperation.
1=Allcontrolregistersareresettodefaultstate(excepttheFeatureRegister)
identicallyafterpower‐up.
Note:TheDi
g
itRe
g
istersmaintaintheirdata.
D2 decode_sel 0 R/W
Se
l
ects
d
isp
l
ay
d
eco
d
ing
f
orse
l
ecte
d

d
igits
0=EnableCode_Bdecoding
1=EnableHEXdecodin
g
D0
sync 0
D1 reg_res 0
NU
blink_freq
sel 0
Externa
l
c
l
oc
k
active.
0=Internaloscillatorisusedforsystemclock
1=PinCLKoftheserialinterfaceo
p
eratesass
y
stemclockin
p
ut.
clk_en 0 R/W
FeatureRegisterBitDescriptions(0x0E)
Bit Bitname Default
Addr:0xXE
Access BitDescription
FeatureRegister
Enablesanddisablesvariousdevicefeatures
X
blink
_
start sync blink
_
fre
q_
sel blink_en NU decode_sel reg_res clk_en
D3 D2 D1 D0D7 D6 D5 D4
1
Table8
FeatureRegister(0x0E)
ShutdownMode,
ResetFeatureRe
g
istertoDefaultSettin
g
s0x00
XXXX
X00XXXX
RegisterData
ShutdownMode,FeatureRegisterUnchanged 0x80
NormalOperation,FeatureRegisterUnchanged 0x81
NormalOperation,
ResetFeatureRe
g
istertoDefaultSettin
g
s0x01 0 X X
ElectroSet™
Table7
ShutdownRegister(0x0C)
Mode HexCode
145Rt.46West
Wayne,NJ07470
Tel:(973) 689-9960
E‐mail:sales@electro‐set.net
Web:www.Electro‐set.net
9of10 rev.1.01
Digit7Intensity
GlobalIntensity
Digit0Intensity
Digit2Intensity
Digit4Intensity
Digit6Intensity
X
Digit1Intensity
Digit3Intensity
Digit5Intensity
Digit
Digit
Digit
Digit
0x10
0x11
0x12
0x13
Table10
IntensityRegisterAddress
RegisterHEXAddress
0x0A Global
Type D7:D4 D3:D0
RegisterData
EFG AABCD DE FG
DIG6
0x1B DIG7
CBDP
D5 D4 D3
0x18 DIG4
DP
0x19 DIG5
0x1A
DIG0
DIG1
DIG2
DIG3
0x14
0x15
0x16
0x17
Segment
Digit D7 D6 D2 D1 D0D1 D0
Segment Reg
i
ster
HEX
Address
These8registerscontaintheresultoftheLEDopen/shorttestfortheindividualLEDofeachdigit.
Reg
i
ster
HEX
Address Digit D7 D6 D5 D4 D3 D2
ChecksifexternalresistorRsetisshorted
0:Rsetcorrect;1:Rsetshorted
D7 0 ‐NotUsed
D6 RSET_short 0 R
Indicatesthatthelastopen/shortLEDtesthasdetectedanerro
r
0:Noerrordetected;1:Errordetected
D5 RSET_open 0 R ChecksifexternalresistorRsetisopen
0Rsetcorrect;1:Rsetiso
p
en
D4 Led_global 0 R
StartsatestforopenLEDs.(CanbesettogetherwithD1)
0:Normalo
p
eration;1:Activatetestmode
D3 Led_test 0 R Indicatesanongoingopen/shortLEDtest
0:Noon
g
oin
g
LEDtest;1:LEDtestin
p
ro
g
ress
D2 Led_open 0 W
Opt
i
ca
l

di
sp
l
aytest.
(
Testmo
d
e
f
orexterna
l
v
i
sua
l
test
)
0:Normaloperation;1Rundisplaytest(Alldigitsaretested
indi
p
endentl
y
fromscanlinit&shutdownre
g
ister.
)
D1 Led_short 0 W StartsatestforshortedLEDs.(CanbesettogetherwithD2)
0:Normalo
p
eration;1:Activatetestmode.
D0 Disp_test 0 W
TestmodeRegistorBitDescription(0x0F)
Addr:0x0F Address
Bit BitName Default Access D7:D0
D0
X RSET_short RSET_open LED_global LED_test LED_open LED_short Disp_test
Table9
Display‐TestMode(0x0F)
D7 D6 D5 D4 D3 D2 D1
ElectroSet™
145Rt.46West
Wayne,NJ07470
Tel:(973) 689-9960
E‐mail:sales@electro‐set.net
Web:www.Electro‐set.net
10of10 rev.1.01
ForMoreinformationregardingthisComponent
http://www.ams.com/eng/content/download/18430/343782/file/AS1115_Datasheet_EN_v2.pdf
ElectroSet™
145Rt.46West
Wayne,NJ07470
Tel:(973) 689-9960
E‐mail:sales@electro‐set.net
Web:www.Electro‐set.net