Care Call CCD4A-2220-EU User manual

Quick start guide CCD4A-2220-EU
Care Call Mini Magnetic Door Monitor
CCM3A-2216-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENT-ALERT.CO.UK CLOFIELD LTD. UK
TEL 01246 260045
Care
Call
MOVE KEY DOWN
TO SWITCH ON
Magnetic Activation
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10= PIR Delay 10 Mins
9& 10 = PIR Delay 15 mins
11= Zone 6
12= Zone 5
13= Zone 4
14= Zone 3
15= Zone 2
16= Zone 1
MOVE KEY DOWN
TO SWITCH ON
Any questions? Call us on 01246 450789
PUSH
PUSH
1 2 3 4 5 6 7 8
Configuration switches shown with
cover removed. Do not alter these
without referring to page 2
Status light
Magnet
Test button
Configuration
switch Cover
CCD4A-2220-EU
CARE CALL
MINI MAGNETIC
DOOR MONITOR
USE ALKALINE PP3
9 V BATTERY ONLY
Batch 06/01/14
www.silent-alert.co.uk
Clofield Ltd. UK
Tel: 01246-260045
Keys 1-4 System
Channel
Key 5=10 Sec Delay
Key 6=20 Sec Delay
Keys 5+6=30 Sec Delay
Key 7 Leave ON
Key 8 Not Used
USE WITH MAGNET SUPPLIED
PP3 battery
contacts
Screw cap
Screw cap
CCD4A-2220-EU
CARE CALL
MINI MAGNETIC
DOOR MONITOR
USE ALKALINE PP3
9 V BATTERY ONLY
Batch 06/01/14
www.silent-alert.co.uk
Clofield Ltd. UK
Tel: 01246-260045
Keys 1-4 System
Channel
Key 5=10 Sec Delay
Key 6=20 Sec Delay
Keys 5+6=30 Sec Delay
Key 7 Leave ON
Key 8 Not Used
USE WITH MAGNET SUPPLIED
PP3 Battery
PUSH
PUSH
The light will then will flash
green several times to show the
battery voltage.
9 flashes = 9Volts in the battery.
When a battery is first fitted the
indicator light will flash red then
green a few times then light
solid green & pause briefly.
1. Install a 9 volt PP3 alkaline or lithium battery
making sure to observe the correct polarity.
PUSH
If the light flashes red at this
point the battery is flat
and will need to be replaced.
To repeat the battery check remove the battery, press the test
button then re-insert the battery to start the sequence again.
PUSH
2.
To test the unit press the
button on the front of the unit.
Alternatively the supplied
magnet can be used to trigger
the unit by swiping it through
the pickup area.
The monitor is activated using an internal reed
switch and a magnet.
Test Button
Magnetic
switch
pickup area
NOTE* The magnet must pass within 1cm of
the pickup area to activate the unit.
3.
Secure the Mini Monitor
to the door frame
as close as possible to the
edge of the door using the
supplied screws.
The Magnet must pass
within 1cm of the pickup
area to trigger the unit.
PUSH
PUSH
4. We recommend mounting the monitor opposite to the
door hinge. The magnet does not need to be in close proximity
to the pickup area when the door is closed as the unit is
triggered when the magnet passes through the pickup area.
The magnet needs to pass within 1cm of the pickup area as
the door is opened. It is possible to mount the monitor in a
variety of positions as shown in the diagram. Experiment to
find the best position before fixing to the door frame.
Once the optimum position has been established the magnet
should be secured to the door frame using the sticky pad or
screws provided.
PUSH
Deactivating & reactivating the door monitor
PUSH
PUSH
Press and hold the test button until the light
flashes red, then release. This will
deactivate the door sensor.
Press and hold the test button until the light
flashes green, then release. This will
reactivate the door sensor.
WARNING! Your device and its accessories are not toys. They may contain small parts. Keep them out of the reach of small children.

Advanced Settings CCD4A-2220-EU
Care Call Mini Magnetic Door Monitor
CCM3A-2216-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENT-ALERT.CO.UK CLOFIELD LTD. UK
TEL 01246 260045
Care
Call
MOVE KEY DOWN
TO SWITCH ON
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10= PIR Delay 10 Mins
9& 10 = PIR Delay 15 mins
11= Zone 6
12= Zone 5
13= Zone 4
14= Zone 3
15= Zone 2
16= Zone 1
MOVE KEY DOWN
TO SWITCH ON
Any questions? Call us on 01246 450789
1.
To change the zone you need to
reset the monitor:
Remove the battery,
press the push button,
replace the battery.
Changing the Zone
The unit will by default cause zone 1 on the pager or signwave to light.
PUSH
Press and release the
button whilst the light
is green. The light will
flash red once, twice
then three times and
so on up to twelve.
3.
PUSH
To set the zone
number, briefly press
the test button at the
desired number of
flashes.
The indicator light will
flash green to confirm
the selection.
4.
The monitor will then
perform the battery voltage
level display and start as
normal. Press the test button
to confirm the correct zone
has been selected.
PUSH
1.
1 2 3 4 5 6 7 8
Remove the control key cover by
with a small flat bladed
screwdriver.
Key 7 will already be set. This
must NOT be switched off.
To activate the trigger delay move
key 5 to the on position.
5.
PUSH
After the flashing red/
green startup
sequence the light will
shine constant green.
2.
Setting trigger delays
It is possible to set trigger delays allowing a set amount of time to pass for the user to clear the door before
the monitor will transmit.
PUSH
Now when the door is
opened the monitor will flash
red for 10 seconds.
If the door doesn't shut
within this time the monitor
will transmit.
2.
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
The delay can
be increased if required.
3.
1 2 3 4 5 6 7 8
10
seconds
1 2 3 4 5 6 7 8
20
seconds
1 2 3 4 5 6 7 8
30
seconds
Changing the system channel code
NOTE. In most cases it is not necessary to change the system code. However, when one or
more systems are in close proximity, system codes can be used to avoid interference from
other Care Call systems using up to a maximum of 16 channels.
The monitor is supplied with no
system code switches set (system code 1).
For reference this is the factory setting
should you need to re-set the unit.
System codes can be set using
key switches 1 - 4.
The diagram to the right shows the 16
possible combinations.
Be sure that the same system code is set on
the receiver to be used and any other
monitoring options in that system.
23456 7 8
1
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
9
1 2 3 4 5 6 7 8
10
1 2 3 4 5 6 7 8
12
1 2 3 4 5 6 7 8
11
1 2 3 4 5 6 7 8
13
1 2 3 4 5 6 7 8
14
1 2 3 4 5 6 7 8
15
1 2 3 4 5 6 7 8
16
1 2 3 4 5 6 7 8
Popular Accessories manuals by other brands

Revolution Lightning
Revolution Lightning rNET-OCC-HV-DT-CM Specifications and installation

STEINEL
STEINEL IR Micro LiveLink Information

Data Harvest
Data Harvest Smart Wireless 1110PK manual

Gems
Gems XT-1000 Technical documentation

Intenso
Intenso WP10000 user manual

saro
saro EGN 4140 TN operating instructions