Advanced Settings CCF3A-2219-EU / GFOB
Care Call Emergency person to person keyfob
CCM3A-2216-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENT-ALERT.CO.UK CLOFIELD LTD. UK
TEL 01246 260045
Care
Call
MOVE KEY DOWN
TO SWITCH ON
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10= PIR Delay 10 Mins
9& 10 = PIR Delay 15 mins
11= Zone 6
12= Zone 5
13= Zone 4
14= Zone 3
15= Zone 2
16= Zone 1
MOVE KEY DOWN
TO SWITCH ON
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
1 2 34
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
56 7 8
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
9 10 11 12
Any questions? Call us on 01246 450789
Changing the zone
NOTE. If you want to use more than one keyfob or have a monitor already set to zone one, the keyfob can be configured
to another zone as follows.
The monitor is supplied with no
zone switches set (zone 1).
For reference this is the factory setting
should you need to re-set the unit.
Zones can be set using
key switches 5 - 8.
The diagram to the right shows the 12
possible combinations.
Changing the system channel code
NOTE. In most cases it is not necessary to change the system code. However, when one or
more systems are in close proximity, system codes can be used to avoid interference from
other Care Call systems using up to a maximum of 16 channels.
The monitor is supplied with no
system code switches set (system code 1).
For reference this is the factory setting
should you need to re-set the unit.
System codes can be set using
key switches 1 - 4.
The diagram to the right shows the 16
possible combinations.
Be sure that the same system code is set on
the receiver to be used and any other
monitoring options in that system.
13
1 2 3 4 5 6 7 8
14
1 2 3 4 5 6 7 8
15
1 2 3 4 5 6 7 8
16
1 2 3 4 5 6 7 8
2 3 4
1
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
9
1 2 3 4 5 6 7 8
10
1 2 3 4 5 6 7 8
12
1 2 3 4 5 6 7 8
11
1 2 3 4 5 6 7 8
56 7 8
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 81 2 3 4 5 6 7 8
Telecare SignWave activation
NOTE. The following setting will not activate a standard Care Call Pager & SignWave. Only use
them with the Care Call CCS3A-2217-EU-TL.
1 2 3 4 5 6 7 8
When configured in this way the Keyfob
will only activate the Care Call Telecare
Link SignWave.
This can be used to trigger an auto
dialler or other third party equipment.
WARNING! PRODUCT CONTAINS A BATTERY.
Battery can explode or leak if heated, disassembled, shorted,
recharged, exposed to fire or high temperature or inserted
incorrectly. Keep in original package until ready to use. Do not carry
batteries loose in your pocket or purse.
Keep batteries away from children. If swallowed, consult a
physician at once.
Under certain misuse conditions and by abusively opening the
battery, exposed lithium can react with water or moisture in the air
causing potential thermal burns or fire.