30XV – AquaForce®Air-Cooled Chiller
Design Series
Nominal Capacity
Voltage
1– 575-3-60
2– 380-3-60
5– 208/230-3-60
6– 460-3-60
9– 400-3-50
G– 400-3-60
H– 380-3-50
J– 415-3-50
K– 440-3-50
Product Tiers& Evaporator Configuration
S– Standard Tier / Flooded Evaporator
M– Mid Tier / Flooded Evaporator
H– High Tier / Flooded Evaporator
- – Flooded Evaporator, 2 pass, without Heater
0– Flooded Evaporator, 2 pass, with Heater
1– Flooded Evaporator with Heater, one pass
2– Flooded Evaporator with Heater for Brine Application, 2 pass
B– Flooded Evaporator, 3pass, with Heater
C– Flooded Evaporator, with Heater for Brine Application, 3pass
R– Remote Evaporator, 2 pass (requiresprocessing viaETO)
Evaporator Options
-
PackagingOptions
L– Coil Face Shipping Protection (CFSP)
0– CFSP, Coil Trim Panels
1– CFSP, Coil Trim Panels, Security Grilles
2– CFSP, Coil Trim Panels, Security Grilles, Hail Guards(End)
3– Full Hail Guard
9– CFSP, Coil Trim Panels, Skid + Bag
B– CFSP, Coil Trim Panels, Security Grilles, Skid + Bag
C– CFSP, Coil Trim Panels, Security Grilles, Hail Guards(End), Skid + Bag
D– Full Hail Guard, Skid, Bag
ControlsOptions
-– 7-in. Touch Pilot™ Display
0– 7-in. Touch Pilot Display, EMM, GFI
1– 7-in. Touch Pilot Display, BACnet†(MS/TP) Translator
2– 7-in. Touch Pilot Display, EMM, GFI, BACnet (MS/TP) Translator
3– 7-in. Touch Pilot Display, LON Translator
4– 7-in. Touch Pilot Display, EMM, GFI, LON Translator
Electrical Options
-– Single Point Power, No Control Transformer, Std SCCR
0– Single Point Power with Disconnect, No Control Transformer, Std SCCR
1– Dual Point Power, No Control Transformer, Std SCCR
2– Dual Point Power with Disconnect, No Control Transformer, Std SCCR
3– Single Point Power, Control Transformer, Std SCCR
4– Single Point Power with Disconnect, Control Transformer, Std SCCR
5– Dual Point Power, Control Transformer, Std SCCR
6– Dual Point Power with Disconnect, Control Transformer, Std SCCR
8 – Single Point Power with Disconnect, No Control Transformer, High SCCR
B– Dual Point Power with Disconnect, No Control Transformer, High SCCR
D– Single Point Power with Disconnect, Control Transformer, High SCCR
G– Dual Point Power with Disconnect, Control Transformer, High SCCR
Valve & Insulation Options
- – No Suction Service Valve, Actuated Discharge Valves,
No Suction Line Insulation
0 – Suction Service Valve, Actuated Discharge Valves,
No Suction Line Insulation
1 – No Suction Service Valve, Manual Discharge Valves
(Middle East only), No Suction Line Insulation
2 – Suction Service Valve, Manual Discharge Valves
(Middle East only), No Suction Line Insulation
5 – No Suction Service Valve, Actuated Discharge Valves,
Suction Line Insulation
6 – Suction Service Valve, Actuated Discharge Valves,
Suction Line Insulation
7 – No Suction Service Valve, Manual Discharge Valves
(Middle East only), Suction Line Insulation
8 – Suction Service Valve, Manual Discharge Valves
(Middle East only), Suction Line Insulation
XV 140
Condenser Options
-– Aluminum Fin/Copper Tube
0– Copper Fin/Copper Tube
1– Aluminum Pre-Coat Fin/Copper Tube
2– Aluminum E-Coat Fin/Copper Tube
3– Copper E-Coat Fin/Copper Tube
4– Microchannel
5– E-Coat Microchannel
Condenser Fans& Sound Options
63H
-– Fixed Speed Condenser Fans(Std Tier) / Variable Speed Fans(Mid and High-Tier),
Std Sound
0– Variable Speed Condenser Fans(Std Tier only), Std Sound
1– Fixed Speed Condenser Fans(Std Tier) / Variable Speed Fans(Mid and High-Tier),
Low Sound Kit
2– Variable Speed Condenser Fans(Std Tier only), Low Sound Kit
3– Fixed Speed Condenser Fans(Std Tier) / Variable Speed Fans(Mid and High-Tier),
Std Sound, Sound Optimization
4– Variable Speed Condenser Fans(Std Tier only), Std Sound, Sound Optimization
5– Fixed Speed Condenser Fans(Std Tier) / Variable Speed Fans(Mid and High-Tier),
Low Sound Kit, Sound Optimization
6– Variable Speed Condenser Fans(Std Tier only), Low Sound Kit, Sound Optimization
7 – Variable Speed High Static Fans, Std Sound
8– Variable Speed High Static Fans, Low Sound Kit
140
160
180
200
225
250
275
300
325
350
400
40A/B*
450
45A/B*
500
50A/B*