INSTALLATION
When mounting the PDM, electrical contact must be made between the vehicle's chassis/earth and the metal
case of the PDM at its mounting points.
12v Power Input is supplied to the PDM via the M6 electrical stud. (Do not over tighten.)
Power Output connections are made using 6.3mm spade terminals.
Each channel is turned ON by connecting the corresponding channel signal wire to chassis/earth. Connection
can be made using dashboard switches, oil pressure switches, thermo-switches, etc. When a Cartek
pushbutton switch, with integrated LED, is used then the LED will display the channel status:
No LED = Channel OFF
LED on = Channel ON
Flashing = ERROR
When short-circuit or over current is detected, the PDM will shut down that channel and the corresponding
LED will begin to flash. To reset the error, switch the channel OFF then ON again.
4
Ch1 Ch2 Ch3 Ch4
.com
4 x 10Amps
+12v Power Input
+
+
Channel status LEDs
No LED = OFF
Yellow = ON
Flashing Red = ERROR
Ch1 - Black wire
Ch2 - Brown wire
Ch3 - Blue wire
Ch4 - White wire
+
+
+
+
Add surge protection diode when controlling
starter solenoids.
Connect close to solenoid.