SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT CO.,LTD
Http://www.carymart.com E-Mail: sale@carymart.com
Press button 1 again: Turn off relay 1 of receiver 1 (disconnect B and C, connect A and B), the lamp1 is off.
Press button 2: Turn on relay 2 of receiver 1 (connect B and C, disconnect A and B), the lamp2 is on.
Press button 2 again: Turn off relay 2 of receiver 1 (disconnect B and C, connect A and B), the lamp2 is off.
…
Press button 11: Turn on relay 1 of receiver 6 (connect B and C, disconnect Aand B), the lamp11 is on.
Press button 11 again: Turn off relay 1 of receiver 6(disconnect B and C, connect Aand B), the lamp11 is off.
Press button 12: Turn on relay 2 of receiver 6 (connect B and C, disconnect A and B), the lamp12 is on.
Press button 12 again: Turn off relay 2 of receiver 6 (disconnect B and C, connectA and B), the lamp12 is off.
2) Setting control mode Momentary: Connect Jumper-1.
Control mode Momentary (with transmitter CV-12 or CB-12): Press and hold -> On; Release -> Off.
Press and hold button 1: Turn on relay 1 of receiver 1 (connect B and C, disconnect A and B), the lamp1 is on.
Release button 1: Turn off relay 1 of receiver 1 (disconnect B and C, connect A and B), the lamp1 is off.
Press and hold button 2: Turn on relay 2 of receiver 1 (connect B and C, disconnect A and B), the lamp2 is on.
Release button 2: Turn off relay 2 of receiver 1 (disconnect B and C, connect A and B), the lamp2 is off.
…
Press and hold button 11: Turn on relay 1 of receiver 6 (connect B and C, disconnect A and B), the lamp11 is on.
Release button 11: Turn off relay 1 of receiver 6 (disconnect B and C, connect A and B), the lamp11 is off.
Press and hold button 12: Turn on relay 2 of receiver 6 (connect B and C, disconnectA and B), the lamp12 is on.
Release button 12: Turn off relay 2 of receiver 6 (disconnect B and C, connect Aand B), the lamp12 is off.
3) Setting control mode Latched: Disconnect Jumper-1 and Jumper-2.
Control mode Latched (with transmitter CV-12 or CB-12): Press -> On, another relay Off; Press another button -> Off.
Press button 1: Turn on relay 1 of receiver 1 (connect B and C, disconnect A and B), the lamp1 is on.
Turn off the other relays of receivers (disconnect B and C, connect Aand B), the other lamps are off.
Press button 2: Turn on relay 2 of receiver 1 (connect B and C, disconnect A and B), the lamp2 is on.
Turn off the other relays of receivers (disconnect B and C, connect Aand B), the other lamps are off.
…
Press button 12: Turn on relay 2 of receiver 6 (connect B and C, disconnect Aand B), the lamp12 is on.
Turn off the other relays of receivers (disconnect B and C, connect Aand B), the other lamps are off.
4) Setting control mode Momentary + Toggle: Connect Jumper-1 and Jumper-2.
Control mode Momentary (Channel 1): Press and hold -> On; Release -> Off.
Press and hold button 1: Turn on relay 1 of receiver 1 (connect B and C, disconnectA and B), the lamp1 is on.
Release button 1: Turn off relay 1 of receiver 1 (disconnect B and C, connect A and B), the lamp1 is off.
Control mode Toggle (Channel 2): Press -> On; Press again -> Off.
Press button 2: Turn on relay 2 of receiver 1 (connect B and C, disconnect Aand B), the lamp2 is on.
Press button 2 again: Turn off relay 2 of receiver 1 (disconnect B and C, connect Aand B), the lamp2 is off.
…
Press button 12: Turn on relay 2 of receiver 6 (connect B and C, disconnect A and B), the lamp12 is on.
Press button 12 again: Turn off relay 2 of receiver 6 (disconnect B and C, connectA and B), the lamp12 is off.
Manual control terminals:
The receiver has manual control terminals, you can connect external devices, sensors, or manual switches to control the receiver.
1) Signal input:
You can connect external devices (with low level output signal) to terminals “1”, “3”, the external device’s output signal can control the receiver.
When the external device outputs low level signal to terminal “1”and “3“, turn on the relay1 (connect terminals B and C, disconnect terminals A and
B).
When the external device does not output signal to terminal “1”and “3“,turn off the relay1 (disconnect terminals B and C, connect terminals A and B).
You can connect external devices (with low level output signal) to terminals “2”, “3”, the external device’s output signal can control the receiver.
When the external device outputs low level signal to terminal “2”and “3“, turn on the relay2 (connect terminals B and C, disconnect terminals A and
B).
When the external device does not output signal to terminal “2”and “3“,turn off the relay2 (disconnect terminals B and C, connect terminals A and B).
2) The manual switches:
You can connect one manual switch to terminals “1”, “3”, and then you can use this manual switch to control the receiver.
When connect terminals “1”and “3”, turn on the relay1 (connect terminals B and C, disconnect terminals Aand B).
And when disconnect terminals “1”and “3”, turn off the relay1 (disconnect terminals B and C, connect terminalsA and B).
You can connect one manual switch to terminals “2”, “3”, and then you can use this manual switch to control the receiver.
When connect terminals “2”and “3”, turn on the relay2 (connect terminals B and C, disconnect terminals Aand B).
And when disconnect terminals “2”and “3”, turn off the relay2 (disconnect terminals B and C, connect terminalsA and B).
How to pair the transmitter to the receiver:
1) Press the button of receiver; signal LED on the receiver keeps shining. The receiver enters into status of LEARNING.
2) Press any one button on remote control. If signal LED flashes quickly 15 times and turns off, it means learning is successful.