SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT CO.,LTD
Http://www.carymart.com E-Mail: sale@carymart.com
2) Connect terminal B to the positive pole of DC power supply, connect terminal A to the positive pole of DC lamp, and connect the negative pole of
DC lamp to the negative pole of DC power supply.
If you want to control anAC 220V lamp, do as following:
1) Connect the positive pole of DC power supply to terminal “L / +”, and connect the negative pole of DC power supply to terminal “N / -”.
2) Connect terminal B to the live wire of AC power supply, connect terminal A to one side of AC lamp, and connect another side of AC lamp to the
neutral wire of AC power supply.
Setting different control modes (We have set the receiver as Toggle control mode before delivery. If you want to use other control modes, do as
following operation):
Setting control mode Toggle: Only connect Jumper-2.
Control mode Toggle (with transmitter CV-6): Press -> On; Press again -> Off.
Press button 1: Turn on relay 1 of Receiver 1 (connect Aand B, disconnect Aand C), the lamp 1 is on.
Press button 1 again: Turn off relay 1 of Receiver 1 (disconnectA and B, connectA and C), the lamp 1 is off.
Press button 2: Turn on relay 2 of Receiver 1 (connect Aand B, disconnect Aand C), the lamp 2 is on.
Press button 2 again: Turn off relay 2 of Receiver 1 (disconnect A and B, connect A and C), the lamp 2 is off.
…
Press button 5: Turn on relay 1 of Receiver 3 (connect Aand B, disconnectA and C), the lamp 5 is on.
Press button 5 again: Turn off relay 1 of Receiver 3 (disconnect A and B, connect A and C), the lamp 5 is off.
Press button 6: Turn on relay 2 of Receiver 3 (connect Aand B, disconnectA and C), the lamp 6 is on.
Press button 6 again: Turn off relay 2 of Receiver 3 (disconnect Aand B, connect Aand C), the lamp 6 is off.
Setting control mode Momentary: Only connect Jumper-1.
Control mode Momentary (with transmitter CV-6): Press and hold -> On; Release -> Off.
Press and hold button 1: Turn on relay 1 of Receiver 1 (connect Aand B, disconnect A and C), the lamp 1 is on.
Release button 1: Turn off relay 1 of Receiver 1 (disconnect Aand B, connect A and C), the lamp 1 is off.
Press and hold button 2: Turn on relay 2 of Receiver 1 (connect Aand B, disconnect A and C), the lamp 2 is on.
Release button 2: Turn off relay 2 of Receiver 1 (disconnect Aand B, connect A and C), the lamp 2 is off.
…
Press and hold button 5: Turn on relay 1 of Receiver 3 (connect Aand B, disconnect A and C), the lamp 5 is on.
Release button 5: Turn off relay 1 of Receiver 3 (disconnect Aand B, connect A and C), the lamp 5 is off.
Press and hold button 6: Turn on relay 2 of Receiver 3 (connect Aand B, disconnect A and C), the lamp 6 is on.
Release button 6: Turn off relay 2 of Receiver 3 (disconnect Aand B, connect A and C), the lamp 6 is off.
Setting control mode Latched: Do not connect Jumper-1 and Jumper-2.
Control mode Latched (with transmitter CV-6): Press -> On, other relays Off; Press another button -> Off.
Press button 1: Turn on relay 1 of Receiver 1 (connect Aand B, disconnect A and C), the lamp 1 is on.
Turn off relay 2 of Receiver 1 (disconnect Aand B, connect A and C), the lamp 2 is off.
Press button 2: Turn on relay 2 of Receiver 1 (connect Aand B, disconnect A and C), the lamp 2 is on.
Turn off relay 1 of Receiver 1 (disconnect Aand B, connect Aand C) the lamp 1 is off.
…
Press button 5: Turn on relay 1 of Receiver 3 (connect Aand B, disconnectA and C), the lamp 5 is on.
Turn off relay 2 of Receiver 3 (disconnect Aand B, connect A and C), the lamp 6 is off.
Press button 6: Turn on relay 2 of Receiver 3 (connect Aand B, disconnect A and C), the lamp 6 is on.
Turn off relay 1 of Receiver 3 (disconnect Aand B, connect A and C), the lamp 5 is off.
Setting control mode Momentary +Toggle: connect Jumper-1& Jumper-2
1) Control mode Momentary (Channel 1 of Receiver 1, 2, 3) (with transmitter CV-6): Press and hold -> On; Release -> Off.
Press and hold button 1: Turn on relay 1 of Receiver 1 (connect Aand B, disconnect A and C), the lamp 1 is on.
Release button 1: Turn off relay 1 of Receiver 1 (disconnect A and B, connect A and C), the lamp 1 is off.
…
Press and hold button 5: Turn on relay 1 of Receiver 3 (connect Aand B, disconnect A and C), the lamp 5 is on.
Release button 5: Turn off relay 1 of Receiver 3 (disconnect A and B, connect A and C) the lamp 5 is off.
2) Control mode Toggle (Channel 2 of Receiver 1, 2, 3): Press -> On; Press again -> Off.
Press button 2: Turn on relay 2 of Receiver 1 (connect Aand B, disconnect A and C), the lamp 2 is on.
Press button 2 again: Turn off relay 2 of Receiver 1 (disconnectA and B, connectA and C), the lamp 2 is off.
…
Press button 6: Turn on relay 2 of Receiver 3 (connect Aand B, disconnect A and C), the lamp 6 is on.
Press button 6 again: Turn off relay 2 of Receiver 3 (disconnectA and B, connectA and C), the lamp 6 is off.
Wired control terminals:
The receiver has manual control terminals, you can connect external devices, sensors, or manual switches to control the receiver.
1) Signal input:
You can connect external devices (with low level output signal) to manual terminals 1 (Signal +), terminal 2 (Signal +) and terminal 3 (Signal -), then
the external device’s output signal can control the receiver.
When the external device outputs low level signal to manual terminal 1 and terminal 3, turns on the relay 1, (connect A and B, disconnect A and C),
the lamp 1 is on.