SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT CO.,LTD
Http://www.carymart.com E-Mail: sale@carymart.com
Press button 11 again: Terminal Aand B of OUT1 of Receiver 6 stop outputting, the lamp 11 is off.
Press button 12: TerminalA and B of OUT2 of Receiver 6 output AC power, the lamp 12 is on.
Press button 12 again: TerminalA and B of OUT2 of Receiver 6 stop outputting, the lamp 12 is off.
Setting control mode Momentary: Only connect Jumper-1.
Control mode Momentary (with transmitter CV-12): Press and hold -> On; Release -> Off.
Press and hold button 1: Terminal A and B of OUT1 of Receiver 1 output AC power, the lamp 1 is on.
Release button 1: Terminal A and B of OUT1 of Receiver 1 stop outputting, the lamp 1 is off.
Press and hold button 2: Terminal A and B of OUT2 of Receiver 1 output AC power, the lamp 2 is on.
Release button 2: Terminal A and B of OUT2 of Receiver 1 stop outputting, the lamp 2 is off.
…
Press and hold button 11: Terminal A and B of OUT1 of Receiver 6 output AC power, the lamp 11 is on.
Release button 11: Terminal Aand B of OUT1 of Receiver 6 stop outputting, the lamp 11 is off.
Press and hold button 12: Terminal A and B of OUT2 of Receiver 6 output AC power, the lamp 12 is on.
Release button 12: Terminal A and B of OUT2 of Receiver 6 stop outputting, the lamp 12 is off.
Setting control mode Latched: Do not connect Jumper-1 and Jumper-2.
Control mode Latched (with transmitter CV-12): Press -> On, other relays Off; Press another button -> Off.
Press button 1: TerminalA and B of OUT1 of Receiver 1 output AC power, the lamp 1 is on.
TerminalA and B of OUT2 of Receiver 1 stop outputting, the lamp 2 is off.
Press button 2: Terminal A and B of OUT2 of Receiver 1 output AC power, the lamp 2 is on.
TerminalA and B of OUT1 of Receiver 1 stop outputting, the lamp 1 is off.
…
Press button 11: TerminalA and B of OUT1 of Receiver 6 output AC power, the lamp 11 is on.
Terminal A and B of OUT2 of Receiver 6 stop outputting, the lamp 12 is off.
Press button 12: TerminalA and B of OUT2 of Receiver 6 outputAC power, the lamp 12 is on.
Terminal A and B of OUT1 of Receiver 6 stop outputting, the lamp 11 is off.
Setting control mode Momentary +Toggle (with transmitter CV-12): connect Jumper-1& Jumper-2
1) Control mode Momentary (Channel 1 of Receiver 1, 2, 3, 4, 5, 6): Press and hold -> On; Release -> Off.
Press and hold button 1: Terminal A and B of OUT1 of Receiver 1 output AC power, the lamp 1 is on.
Release button 1: Terminal Aand B of OUT1 of Receiver 1 stop outputting, the lamp 1 is off.
…
Press and hold button 11: Terminal A and B of OUT1 of Receiver 6 output AC power, the lamp 11 is on.
Release button 11: Terminal Aand B of OUT1 of Receiver 6 stop outputting, the lamp 11 is off.
2) Control mode Toggle (Channel 2 of Receiver 1, 2, 3, 4, 5, 6): Press -> On; Press again -> Off.
Press button 2: Terminal A and B of OUT2 of Receiver 1 output AC power, the lamp 2 is on.
Press button 2 again: Terminal A and B of OUT2 of Receiver 1 stop outputting, the lamp 2 is off.
…
Press button 12: Terminal A and B of OUT2 of Receiver 6 output AC power, the lamp 12 is on.
Press button 12 again: TerminalA and B of OUT2 of Receiver 6 stop outputting, the lamp 12 is off.
Wired control terminals:
The receiver has manual control terminals, you can connect external devices, sensors, or manual switches to control the receiver.
1) Signal input:
You can connect external devices (with low level output signal) to manual terminals 1 (Signal +), terminal 2 (Signal +) and terminal 3 (Signal -), then
the external device’s output signal can control the receiver.
When the external device outputs low level signal to terminal 1 and 3,Terminal A and B of OUT1 output AC power, the lamp 1 is on.
And when disconnect terminals 1 and 3, Terminal A and B of OUT1 stop outputting, the lamp 1 is off.
When the external device outputs low level signal to terminal 2 and 3,Terminal A and B of OUT2 output AC power, the lamp 2 is on.
And when disconnect terminals 2 and 3, TerminalA and B of OUT2 stop outputting, the lamp 2 is off.
2) The manual switches:
You can connect manual switches to manual terminals 1, 2 and 3, then you can use manual switches to control the receiver.
When connect terminals 1 and 3, Terminal Aand B of OUT1 output AC power, the lamp 1 is on.
And when disconnect terminals 1 and 3, TerminalA and B of OUT1 stop outputting, the lamp 1 is off.
When connect terminals 2 and 3, TerminalA and B of OUT2 outputAC power, the lamp 2 is on.
And when disconnect terminals 2 and 3, Terminal A and B of OUT2 stop outputting, the lamp 2 is off.
How to pair the transmitter to the receiver:
1) Press the learning button of receiver for 1- 2 seconds; signal LED on the receiver is on. The receiver enters into status of LEARNING.
2) Press any one singular number on transmitter. If signal LED flashes quickly 15 times and turns off, it means learning is successful.
3) When receiver is in the status of LEARNING, press again the learning button, signal LED turns off, learning process will be discontinued.
4) The receiver can learn several remote controls with different codes.