manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cash Acme
  6. •
  7. Control Unit
  8. •
  9. Cash Acme SoloSet EB25 User manual

Cash Acme SoloSet EB25 User manual

This manual suits for next models

2

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Adjustment
Knob
Pressure
Indicator
Pressure
Reducer
Cartridge
Direction
Arrow
A division of the Reliance Worldwide Corporation
Installation:
Thoroughly flush out the system before
installing valve. It is recommended that isolat-
ing valves be installed both upstream and
downstream to ease in servicing the valve. Install in an
accessible location and orient the valve to correspond
with the direction of flow (indicated by arrow on the Valve
Body)(Fig. 1). Avoid stressing the valve by ensuring that
inlet and outlet pipework are properly supported and
aligned.
Viewing Pressure
Indicator:
If necessary, the
Pressure Reducer
Cartridge can be
rotated to best view the
Pressure Indicator. The
outlet pressure is factory
preset to the value
indicated by the
Pressure Indicator. The
Pressure Indicator will
display approximate
outlet pressure. (Fig. 2)
IMPORTANT!
Do not turn
pressure indicator to
adjust outlet pressure
Fig. 1
Pressure Adjustment:
To adjust outlet pressure,
pull the ORANGE
Adjustment Knob upward
(Fig.3) then turn counter
clockwise (-) to decrease
pressure or clockwise (+) to
increase pressure. (Fig. 4)
Snap the knob back down
to lock its position after
adjusting. (Fig.5)
1 2
3
SoloSet
TM
2400 7th Ave. SW,
Cullman, Al 35055
www.cashacme.com
1-877-700-4242
Fig. 2
Fig. 3
Fig. 4
Please turn over for
additional instructions.
Fig. 5
For Water Service, with Bronzeor Stainless SteelBody and Inbuilt Back-Pass-Check
Type EB25, EB25-SS & EB25-400
PRESSURE REDUCING VALVE
Pressure Indicator
Pressure Reducer Cartridge
Adjustment Knob
Cartridge Nut
Valve Body
Burial Cover
Strainer Screen
O-Ring
Coupling Nut
O-Ring
Union Tailpiece
INLET
Remove the Pressure Reducer Cartridge by pulling
straight up. (Fig. 8) Clean with cold water only.
Replace the Strainer Screen before re-installing the
Pressure Reducer Cartridge. (Fig. 9) Orient the
Pressure Reducer Cartridge to best view indicator.
Maintenance:
Close isolating valves upstream and
downstream before attempting to
service the valve. Unscrew the
Cartridge Nut. (Fig. 6 and Fig. 7)
4 5
Type EB25, EB25-SS & EB25-400
PRESSURE REDUCING VALVE
For Water Service, with Bronze or Stainless Steel Body
and Inbuilt Back-Pass-Check
2400 7th Ave. SW • Cullman, Al 35055 • www.cashacme.com
Fig. 7
Fig. 12 Fig. 13
Fig. 6
Fig. 9
Fig. 8
Sold Separately
California “Propostition 65” Warning:
This product contains a chemical known to the State of California to cause cancer,
birth defects or other reproductive harm.
Note to Installer/Contractor: California law requires that this notice be provided to the
consumer/end user of this product.
Water
Meter
2000
Series
Ball
Valve
EB-25
Pressure
Regulator
VR-801
Vacuum
Relief
Main
Supply
BF
Backflow
Preventer
Floor
Drain
Cold
Supply to
Fixtures
Tempered
Supply to
Fixtures
Heatguard
110-D
Mixing Valve
NCLX
T&P
Valve
TE Thermal
Expansion
Tank
2000
Series
Ball
Valve
Typical Installation
Schematic
I0445 REV. B
EB25-400 & EB25-SS . . . . . . 20-90 psi
Performance:
Outlet pressure range:
EB25 . . . . . . . . . . . .. . 8-35 or 20-90 psi
Maximum temperature . . . . . . . .180° F
Maximum initial pressure:
EB25-400 . . . . . . . . . . . . 400 psi
EB25 & EB25SS . . . . . . . 300 psi
Service . . . . . . . . . . . . . . . . . Water
Fig. 10 Fig. 11
Orient direct burial cover in such a way that it can
be snapped into position. (Fig. 12 and 13)
Burial Instructions (Optional Cover)
Available for sizes 1/2", 3/4" & 1" only:
Burial Depth should be in accordance
with local plumbing codes.
After valve is installed, reset pressure if necessary,
(see Operation Instructions). Make sure valve is
clean of dirt and debris. Slip provided O-Ring
over cartridge until seated against Cartridge Nut.
SoloSet
TM
EB25 Multi-Cartridge . . 250 psi