manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Casio
  6. •
  7. Watch
  8. •
  9. Casio 5276 User manual

Casio 5276 User manual

Other Casio Watch manuals

Casio 5415 User manual

Casio

Casio 5415 User manual

Casio G2310R-1 User manual

Casio

Casio G2310R-1 User manual

Casio 5129 User manual

Casio

Casio 5129 User manual

Casio 5374 User manual

Casio

Casio 5374 User manual

Casio 3227 User manual

Casio

Casio 3227 User manual

Casio 2090 Configuration guide

Casio

Casio 2090 Configuration guide

Casio QW-999 Configuration guide

Casio

Casio QW-999 Configuration guide

Casio AQ47-1E User manual

Casio

Casio AQ47-1E User manual

Casio 2291 User manual

Casio

Casio 2291 User manual

Casio 2512 User manual

Casio

Casio 2512 User manual

Casio 3089 User manual

Casio

Casio 3089 User manual

Casio AWM-500D-1A8 User manual

Casio

Casio AWM-500D-1A8 User manual

Casio QW-987 User manual

Casio

Casio QW-987 User manual

Casio Edifice EQB-900DB-2AER User manual

Casio

Casio Edifice EQB-900DB-2AER User manual

Casio G-Shock MTG-900D-2V User manual

Casio

Casio G-Shock MTG-900D-2V User manual

Casio 2709 User manual

Casio

Casio 2709 User manual

Casio 3118 User manual

Casio

Casio 3118 User manual

Casio 2196 User manual

Casio

Casio 2196 User manual

Casio 3267 User manual

Casio

Casio 3267 User manual

Casio QW-742 User manual

Casio

Casio QW-742 User manual

Casio QW-2802 User manual

Casio

Casio QW-2802 User manual

Casio 3752 User manual

Casio

Casio 3752 User manual

Casio 3417 User manual

Casio

Casio 3417 User manual

Casio 3075 User manual

Casio

Casio 3075 User manual

Popular Watch manuals by other brands

Piaget 560P Instructions for use

Piaget

Piaget 560P Instructions for use

Armitron pro sport MD0346 instruction manual

Armitron

Armitron pro sport MD0346 instruction manual

West Marine BlackTip 13411293 Instruction Booklet and Care Guide

West Marine

West Marine BlackTip 13411293 Instruction Booklet and Care Guide

Jaeger-leCoultre HYBRIS MECHANICA CALIBRE 184 manual

Jaeger-leCoultre

Jaeger-leCoultre HYBRIS MECHANICA CALIBRE 184 manual

FOREVER iGO PRO JW-200 user manual

FOREVER

FOREVER iGO PRO JW-200 user manual

Relic OS10 quick start guide

Relic

Relic OS10 quick start guide

MyKronoz ZeClock manual

MyKronoz

MyKronoz ZeClock manual

Strikes and Spares SASM80 E-manual

Strikes and Spares

Strikes and Spares SASM80 E-manual

Christopher Ward C1000 Owner's handbook

Christopher Ward

Christopher Ward C1000 Owner's handbook

Lotus ILMFS01 instruction manual

Lotus

Lotus ILMFS01 instruction manual

Chronos Manufactures Chrono Diamond Thyrso 10400 instruction manual

Chronos Manufactures

Chronos Manufactures Chrono Diamond Thyrso 10400 instruction manual

Pandora WATCH2 quick guide

Pandora

Pandora WATCH2 quick guide

Suunto X6 user guide

Suunto

Suunto X6 user guide

Seiko N830 instruction manual

Seiko

Seiko N830 instruction manual

MotionX 365 user guide

MotionX

MotionX 365 user guide

Aplus GV18 user guide

Aplus

Aplus GV18 user guide

Garmin VENU SQ 2 owner's manual

Garmin

Garmin VENU SQ 2 owner's manual

QCY Watch GTC manual

QCY

QCY Watch GTC manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
Operation Guide 5276
MA1201-EA
To change the day indicator setting
To adjust the time setting
Pull the Crown out to Click 1.
Push the Crown back in.
Push the Crown back in.
Rotate the Crown to change the
time setting.
When the second hand is at
12 o’clock, pull the Crown out to
Click 2.
Rotate the Crown away from you
to set the day.
Note
Take care that you set the correct AM

or PM time.
When changing the time, move the

minute hand four or five minutes past
your final setting, and then back it up
to the setting you want.
Note
The day indicator setting uses a 31-

day month. Make adjustments for
months of shorter lengths.
Avoid changing the day indicator

setting between the hours of 9
p.m. and 1 a.m. Otherwise, the day
indicator may not change correctly at
midnight.
Specifications
Accuracy: ±20 seconds average per month
Stopwatch: Measuring Capacity: 11:59'59.95" (12 hours)
Measuring Unit: 1/20 second
Measurements: Elapsed time; split time; two finishes
Battery: One silver oxide battery (Type: SR927SW)
Battery Life: Approximately 3 years (2 hours stopwatch operation per day)
Stopwatch functions
Crown Operations
Some water-resistant models (100 meters, 200 meters)
have a screw-in crown. When you need to perform a crown
operation, rotate it towards you to unscrew it. Then pull
the crown out. Avoid applying undue force when pulling.
The watch loses its water resistance while the crown is
unscrewed. After performing a crown operation, fully screw
the crown back in.
Crown
Loosen
If your watch has a rotary bezel...
You can rotate the bezel to align its ▼mark with the
minute hand. Then you will be able to tell how much
time has elapsed since aligning the ▼mark.
Start
Elapsed time
Current
Your watch may differ somewhat from the one shown in the illustration.
Some models may use a combination of hands and rotating disks to indicate
information. The word “hand” in this section is used to mean both analog hands
and rotating disks.
Using the Stopwatch
Elapsed time
AAAAB
Start Stop Re-start Stop Reset
Split time
ABBAB
Start Split Split release Stop Reset
Two finishes
ABABB
Start Split
First runner
finishes.
Display time of
first runner.
Stop
Second runner
finishes.
Split release
Display time of
second runner.
Reset
Important!
Do not operate the stopwatch with the crown pulled out.

Note
The stopwatch 1/20-second hand will move for 10 minutes after you start an

elapsed time operation. After that, it will stop at 0. When you stop the elapsed time
operation, the 1/20-second hand will move to the 1/20-second reading for the
current elapsed time.
The stopwatch measures elapsed time in 1/20-second increments up to 11 hours,
59 minutes, 59.95 seconds.
Perform the following procedure if the stopwatch hands do not return to their 0 (zero)
positions when you reset the stopwatch.
Use the Abutton to select the hand whose zero position you want to correct. Each
time you hold down Afor about two seconds in the following procedure, it cycles to
the next hand to be corrected.
Use the Bbutton in the following procedure to correct the 0 position of the currently
selected hand. Holding down Bmoves the current hand at high speed.
Correcting the 0 Positions of the Hands
Operational Flow
Pull the Crown out to Click 2.
Hold down Afor about two seconds, the Stopwatch 1/20-second Hand will
rotate to indicate the 1/20-second hand setting mode.
If the hand does not align with 00, use the
Bbutton to adjust it.
Hold down Afor about two seconds, the Stopwatch Second Hand will rotate
to indicate the second hand setting mode.
If the hand does not align with 12 o’clock, use the
Bbutton to adjust it.
Hold down Afor about two seconds, the Stopwatch Hour Hand and
Stopwatch Minute Hand will rotate to indicate the hour hand and minute hand
setting mode.
If the hands do not align with 0 hours and 0 minutes, use the
Bbutton to adjust
them.
After all of the hands are the way you want, push the Crown back in.
Important!
Timekeeping stops while the crown is pulled out. Correct the current time setting

after performing the above operation.

Second Hand
Day Indicator
Click 2Click 1
Hour Hand Minute Hand
A
B
Stopwatch 1/20-second Hand
Stopwatch Second Hand
Stopwatch Hour Hand
Crown
Stopwatch Minute Hand