Cateye OHR-30 User manual

1. Before use: How to charge
OHR-30
Charging precautions
•Avoid charging under direct sunlight or in a vehicle parked under direct sunlight, and make
sure to charge only when the ambient temperature is between 5 and 40°C.
• Before charging, be sure that no dust or other foreign objects are attached to the USB plug.
• When the connected PC is in the sleep state, the battery cannot be charged.
• Do not subject the device to vibrations while charging.
Usage precautions
• Charging, discharging, and storing in high temperature environments will cause the
rechargeable battery to deteriorate faster. Do not place the product inside a vehicle or near a
heater.
• If the operating time is significantly reduced even after proper charging, the rechargeable
battery may be reaching the end of its service life. Dispose of the battery according to the
disposal precautions.
Storage precautions
If the device will not be used for a long period of time, store it in a location that is not too hot or
too humid. In addition, charge the battery for about 30 minutes every 6 months.
Disposal precautions
When disposing of the product, remove the internal rechargeable battery and dispose of it
according to local regulations.
Caution!
When using this sensor with a CATEYE computer, the heart rate display will flash when the
remaining battery power is low.
Important
Be sure to charge it before use, according to the instructions “How to charge” and “Charging
precautions”.
Handling the rechargeable battery
Recharge the sensor if the computer's heart rate display starts flashing.

Copyright© 2020 CATEYE Co,.Ltd.
The indicator turns red and charging starts.
The indicator turns blue to indicate that charging is complete.
* When your PC is in sleep state, the unit may not be charged.
* Charging and operating times are approximate values, and will vary by environmental and user
conditions.
USB charging cable connector
LED indicator
Contact
Standard charging time
Approx. 1.5 hours
Continuous operating time
Approx. 8 – 10 hours
1. Attach the USB charging cable connector to the contact of the heart rate
sensor, and charge using a PC or a commercially available USB charger.
Be careful that metal objects do not touch the contacts of the charging cable connector. This
Caution!
could lead to an electrical short circuit and damage the device.
-

1. Before use: How to charge
2. Pairing
OHR-30
This section explains how to pair the smart computer and the sensor using the “Cateye
Cycling™” smartphone app.
To pair the sensor directly to the computer without a smartphone, refer to your computer’s
online manual or instruction manual.
Important
The Cateye Cycling™ smartphone app (free) must be installed on the smartphone to be used in
advance.
* For the latest information on the smartphones that are compatible with Cateye Cycling™
operations, see “Cateye Cycling™ Recommended Devices”.
If using an iPhone If using an Android smartphone

Tap [Pair to Device] to start pairing.
2. Press the heart rate sensor button to transmit the signal.
The indicator flashes blue.
When Cateye Cycling™ detects the sensor signal, a message will be displayed on the
smartphone.
Tap [Pair to Device]. The verified sensor (CATEYE OHR-30) is displayed under [Device] and
pairing is completed.
* When pairing a sensor with the Cateye Cycling™ app an “A” is displayed after the sensor
name (HR).
Press
LED indicator
Smartphone
1. Verify that [Connect] is set to ON in the (MENU), and then tap [Device].
Pairing via Bluetooth
Perform pairing at a distance of no more than 3 m.
Important

Copyright© 2020 CATEYE Co,.Ltd.
Heart rate will not be displayed on the measurement screen in default configuration.
Customize the measurement screen to display heart rate.
AVVEBTURA: Changing the measurement screen
PADRONE SMART+: Changing the measurement screen
When using ANT+ to perform pairing or pairing with a commercial computer
Refer to the instruction manual for your computer.
-
• When using the smart computer in Sensor Direct Mode:
Connect the smart computer to Cateye Cycling™, and then transmit the paired sensor
information.
STRADA SMART/PADRONE SMART: Connecting smart computer and smartphone
PADRONE SMART+: Connecting smart computer and smartphone
• When using AVVENTURA/PADRONE SMART+:
Important
3. After pairing is complete, turn off the power of the heart rate sensor.
Press and hold the heart rate sensor button, and release your finger when the LED indicator
turns red.

1. Before use: How to charge
3. Using the optical heart rate sensor
OHR-30
Never use this device if you are using a pacemaker.
Warning!!!
• Secure the sensor appropriately using the wrist band so that the optical sensor part makes
close contact with the skin.
• If an allergic reaction or skin inflammation occurs during use, stop using immediately, and
consult with a doctor.
• When the outside temperature is low, the heart rate may not be measured correctly. In these
situations, use your cycling wear or other object to warm the sensor, and then perform
measurement.
•This sensor cannot be used underwater.
Wear the optical heart rate sensor on your arm.
Before wearing the heart rate sensor
2. Wear the sensor on your wrist, forearm, or upper arm using the wrist band.
Adjust the length of the wrist band, and secure the sensor in place. Overtightening the wrist
band may cause discomfort during measurement.
1. Press the heart rate sensor button to turn on the sensor.
The indicator flashes blue.
Press
LED indicator
2. Pairing

Copyright© 2020 CATEYE Co,.Ltd.
* Ensure that the optical sensor part is in close contact with your body.
* If the heart rate cannot be measured correctly, try again by wearing on a different area
(wrist, forearm, upper arm).
3. After measurement is complete, turn off the power of the heart rate sensor.
Press and hold the heart rate sensor button, and release your finger when the LED indicator
turns red.
Wrist band

Handling and Support
Optical heart rate sensor
OHR-30
Warning!!! / Caution!
Warning!!!
Never use this device if you use a pacemaker.
Caution!
Be careful that metal objects do not touch the contacts of the charging cable connector of the
optical sensor. This could lead to an electrical short circuit and damage the device.
Handling the rechargeable battery
Charging precautions
•Avoid charging in direct sunlight or in a vehicle parked under direct sunlight, and make sure
to charge only when the ambient temperature is between 5 and 40°C.
• Before charging, be sure that no d st or other foreign objects are attached to the USB plug.
• When the connected PC is in the sleep state, the battery cannot be charged.
• Do not subject the device to vibrations while charging.
Usage precautions
• Charging, discharging, and storing in high temperatures will cause the rechargeable battery
to deteriorate faster. Do not place the product inside a vehicle or near a heater.
• If the operating time is significantly reduced even after proper charging, the rechargeable
battery may be nearing the end of its service life. Dispose of the battery according to the
disposal precautions.
Storage precautions
If the device will not be used for a long period of time, store it in a location that is not too hot
or too humid. In addition, charge the battery for about 30 minutes every 6 months.
Disposal precautions
When disposing of the product, remove the internal rechargeable battery and dispose of it
according to local regulations.

Specifications
Batteries used Lithium-ion polymer battery 50 mAh
Continuous operating
time
Approx. 8 – 10 hours
*The continuous operating time is approximate and will vary
according to environmental and user conditions.
Standard charging time Approx. 1.5 hours
*The standard charging time is approximate and will vary
according to environmental conditions during charging.
Number of
recharges/discharges
300 standard charges (until rated capacity is reduced to 70%)
Transmission/reception Bluetooth 4.1 / ANT+
Signal range Approx. 30 m (within 3 m when pairing)
(The range will vary depending on weather and surroundings.)
Temperature range Charging: 41°F – 104°F (5°C – 40°C), Operating: 32°F – 104°F
(0°C – 40°C)
* When the outside temperature is low, the heart rate may not be
measured correctly.
Waterproof IPX7
*This device is rated IPX7 based on JIS C0920.
Maintenance
If the sensor unit becomes dirty, clean with a soft cloth moistened with mild detergent, and
then wipe with a dry cloth.
Never apply paint thinner, benzine or alcohol; damage will result.
Dimensions/weight 1-25/32" x 1-3/8" x 25/64" (45.3 x 34.9 x 9.8 mm) / 0.32 oz (9.2
g) (Not including wrist band)
* Specifications and design are subject to be changed without notice.

Product warranty
2-year guarantee
Sensor unit (Accessories and battery deterioration excluded)
CatEye cycle computers are warranted to be free of defects from materials and workmanship
for a period of two years from original purchase. If the product fails to work due to normal use,
CatEye will repair or replace the defect at no charge. Service must be performed by CatEye
or an authorized retailer. To return the product, pack it carefully and enclose the warranty
certificate (proof of purchase) with instruction for repair. Please write or type your name and
address clearly on the warranty certificate. Insurance, handling and transportation charges to
CatEye shall be borne by person desiring service. For UK and REPUBLIC OF IRELAND
consumers, please return to the place of purchase. This does not affect your statutory rights.
2-8-25, Kuwazu, Higashi Sumiyoshi-ku, Osaka 546 - 0041 Japan
Attn: CATEYE Customer Service Section
Phone: (06)6719-6863
Fax: (06)6719-6033
E-mail: [email protected]
URL: https://www.cateye.com
[For US Customers]
CATEYE AMERICA, INC.
2825 Wilderness Place Suite 1200, Boulder CO 80301-5494 USA
Phone: 303.443.4595
Toll Free: 800.5.CATEYE
Fax: 303.473.0006
E-mail: [email protected]

Federal Communication Commission Interference Statement
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassB
digitaldevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedto
providereasonableprotectionagainstharmfulinterferenceinaresidential
installation.
Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnot
installedandusedinaccordancewiththeinstructions,maycauseharmful
interferencetoradiocommunications.However,thereisnoguaranteethat
interferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescause
harmfulinterferencetoradioortelevisionreception,whichcanbedeterminedby
turningtheequipmentoffandon,theuserisencouragedtotrytocorrectthe
interferencebyoneofthefollowingmeasures:
.Reorientorrelocatethereceivingantenna.
.Increasetheseparationbetweentheequipmentandreceiver.
.Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthe
receiverisconnected.
.Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
FCCCaution:Toassurecontinuedcompliance,anychangesormodificationsnot
expresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser's
authoritytooperatethisequipment.(Example‐useonlyshieldedinterfacecables
whenconnectingtocomputerorperipheraldevices).
FCCRadiationExposureStatement
ThisequipmentcomplieswithFCCRFradiationexposurelimitssetforthforan
uncontrolledenvironment.
Thistransmittermustnotbeco‐locatedoroperatinginconjunctionwithanyother
antennaortransmitter.
ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothe
followingtwoconditions:
(1)Thisdevicemaynotcauseharmfulinterference,and(2)Thisdevicemustaccept
anyinterferencereceived,includinginterferencethatmaycauseundesired
operation.

IndustryCanadaStatement
ThisdevicecomplieswithIndustryCanadalicence‐exemptRSSstandard.
Operationissubjecttothefollowingtwoconditions:(1)thisdevicemaynotcause
interference,and(2)thisdevicemustacceptanyinterference,includinginterference
thatmaycauseundesiredoperationofthedevice.
LeprésentappareilestconformeauxCNRd'IndustrieCanadaapplicablesaux
appareilsradioexemptsdelicence.L'exploitationestautoriséeauxdeuxconditions
suivantes:(1)l'appareilnedoitpasproduiredebrouillage,et(2)l'utilisateurde
l'appareildoitacceptertoutbrouillageradioélectriquesubi,mêmesilebrouillageest
susceptibled'encompromettrelefonctionnement.
ICRadiationExposureStatement:
ThisequipmentcomplieswithICRSS‐102radiationexposurelimitsetforthforan
uncontrolled environment.
Cet équipementestconformeauxCNR‐102d'IndustrieCanada.
Table of contents
Other Cateye Heart Rate Monitor manuals