TLE
FUNCTIONS
F.1 DEALER CALIBRATION
F.2 DISPLAY/SEGMENT CHECK
F.3 OFF-SET VALUE
F.4 AUTOMATIC “OFF” FUNCTION
The scale must be “OFF” at the onset for performing all functions.
When instructed to PRESS a key, be sure to do so FIRMLY.
_________________________________________________________________________
TO ENTER FUNCTION MODE
1) With the scale turned “OFF”, press and hold “TARE”. While holding “TARE” down, quickly press and
release “ON”. Release “TARE”.
2) Display will read “F.1” (if display reads “F.0”, press “TARE” again which will display “F.1”)
3) Select specific functions by pressing “TARE” until proper selection is displayed.
4) To exit, press “ON”.
* after each adjustment, scale must be re-calibrated *
_________________________________________________________________________
F.1 DEALER CALIBRATION
1) Press and hold “TARE” button. While holding “TARE” button, quickly press “ON” and release both. Display
should read “F.1”.
2) Press “ZERO” to display current off-set value.
3) Off-set value should be between 5,000 and 15,000. If value is not within this range, go to step “F.3” below.
4) Press “ON” to zero the scale
5) Press “TARE” ,“ON”, “TARE”, “ON”. Display should read “1” while depressing “TARE” and “2” when “ON” is
depressed.
6) Display should read “===Þ” opposite the “ZERO” key. If it does not appear, turn the scale “OFF” and start
again at Step 1.
7) Place full capacity weight on scale (except TLE-70; add 50 lb.) on platform and allow display to stabilize.
8) Press “ZERO”
9) The scale should “automatically” calibrate and display should read “donE”.
10) The display will show a numerical “count down” which should reflect the weight on the platform or “0” if calibra-
tion weights have been removed.
F.2 DISPLAY/SEGMENT CHECK
1) Press “TARE” and hold. At the same time, quickly press and release “ON”. Release “TARE”.
2) Display should read “F.1” (if the display reads “F.0”, press “TARE” again, which will display “F.1”).
3) Press “TARE” until display reads “F.2”.
4) Press “ZERO” to enter DISPLAY/SEGMENT CHECK function. Display will illuminate all segments of the
display to check for failure or damage.
5) Return to NORMAL operation by pressing “ON”.
The scale is now ready for the Weights & Measurement authority to seal. This is accomplished by placing a lead
wire through the protrusion in the circular hole on the underside of the scale and connecting it with a blob of lead
mashed with the “official seal”.