CEBEK DA-03 User manual

ELECTRONIC CIRCUITS
ACCESSCONTROLWITHKEYBOARD
TheDA-03modulewillallowtocontroltheaccessthankstoakeyboardanyplaceordevice.Youcouldinsertupto10
differentcodes(composedby4numberseachcode)whichwillbestoredinmemoryevenifyoustoptosupplythe
module.Itallowstoauthorizeanddenycodesandoffersarelayoutput.Theoutputcouldbeflip-floportimedtypes
withtimesadjustablebetween1and60sec.Or1and60minutes.
Itincludessignalleds,acousticsignal,keyboardandconnectionterminals.
OPERATING.
TECHNICALCHARACTERISTICS.
Voltage............................................................................................ 12V.DC.
MinimumConsumpitono................................................................10mA.
MaximumConsumption.................................................................60mA.
Relaytiming.....................................................................................Between1and60sec./min.
MaximumLoadtotherelay.............................................................5A.
Maximumdifferentcodes................................................................10.
Maximumtrialsbeforeauto-blocking..............................................5.
Maximumtimeonauto-blockngstate..........................................5minutes.
CircuitSizes......................................................................................90x70x30mm.
KeyboardsizeswithcommunicationPCB........................................76x51x20mm.
Keyboradsizes................................................................................64x51x12mm.
Comunicationcablelength.............................................................150mm.
1
POWERSUPPLY.
OPERATING.
Doneverdesold,separateormakelongerthecommunicationcableinstalledbetwenthePCBandthe
keyboard.
The
youhavetoproceed
accordingtofollowinginstructions:
-
Ifyoudonotrespectthispoint,themodulecouldbedamagedandthewarrantycancelled.
-Installthemoduleonanenclosurecorrectlyventilated.Ifyouhavetoinstallthemoduleoutside,useawatertight
enclosurewithaminimuminteriorspacetoallowstothemoduletodissipateheatwithoutanyproblemduringits
operating.
-Then,youhavetoprotecttheDA-03moduleagainstbadweather,excessivehumidityaswellasagainstdevicesor
apparatusgeneratingindustrialparasitesascoils,motors,neons,etc..
DA-03circuithadtobesuppliedbya12VDCpowersupplycorrectlyfiltered.Werecommendedyouthe
FE-2powersupplywhichhasbeendevelopedtoperfectlyanswertothecircuitneeds.Installafuseandaswitchhasiti
sindicatedontheschedule.Botharenecessaryforthemodule’sprotectionaswellasforyourownsafety,asitisrequiredbyteh
“CE”regulations.Connectthepositiveofthepowersupplytothepositiveterminalindicatedinthewiringmap,then connect
thenegativeofthepowersupplytothenegativeterminalindicatedinthecircuit..
Themoduleoperatingcouldbedividedaccordingtwoparts(orconcepts):anditsuse
in.
Verifythattheassemblyiscorrect
Operationscontrol
commonwork
Beforetoexplaintheoperationscontroloritsuseinstandardway,INFORMATIONABOUTTHEDA-03.
OPERATIONSCONTROL. Thankstotheoperationscontrolyoucouldauthorizeanddenyaccesscodeaswellasprogram
relaytiming.Toactivatetheopetaionscontrolmode,youhavetoconnect,closeorshort-circuitbothterminalsoftheJP1
jumperusingtheJPpiecesuppliedwiththemodule.Seethecorrespondingschedule.
WhentheDA-03isonthismode,themodulecouldnotbeusedasaccesscontrol,andonlyacceptoperationscontrol
management.
JumpernotClosed
(Open)
Jumper
Closed
JPPiece

DOMOTIC Ref.Full9928
2
OPERATING.
AssoonastheJP1Jumperisclosed,bothLedsONandOFFwillintermittentlylighttoindicatethattheOperations
Controlmodeisactivated.
Accesscodesarecomposedby4numbers(from0upto9)and
youcouldstoreinmemoryamaximumof10differentcodes.Thetenmemoriesallowingtostorecodesarethetendigits
OPERATIONSCONTROL.Toauthorizeaccesscodes.
Adigitcouldnotstoretwodifferentaccesscode;youhavetopreviouslydenytheanteriorcode.Ifyoudonotdenythe
anteriorcode,theOFFledwilllightandanacousticsignalwillbeemitedtoindicatethemistake.
Whenyouareintothememoryoftheselecteddigit(Chargeledlighting),youhavetointroducethecodecomposedby4
digitusingthekeyboardandpressingthedigit“”.Ifyouhavecorrectlydonetheoperation,themodulewillrequireyouto
confirmthecodetodefinitivelystoreit,maintainingthe“charge”ledlightingandONledintermittent.Thenintroduce
againthecodeandpressthedigit“”.Finally,andifyouhavecorrectlyproceed,anacousticsignalwillbeemitedand
Charge&ONLedswilllight.Afterashorttime,themodulewillbebackattheOperationscontrolmode(ON&OFFled
alternativelyintermittent)andthecodehasbeencorrectlystored.Youhavetodothisoperationforeachaccesscodethat
youneedtillamaximumof10codes.
Ifyouwronglyproceedtoauthorizeacode,astowaitmoretimethanauthorisedforthecodeconfirmation,orto
introducemoreorlessthan4digit,thecircuitwillemitanacousticsignalandtheOFFLedwillmomentarilylighttoindicate
theerror.
Eachtimeyoufinishacontroloperationastoauthorizeanaccesscode,youhavetowaitthatthecircuitindicatesyou (ON
&OFFLedshavetoalternativelylight)thepossibilitytoinsertanewcode.
*
*
HOWTOAUTHORISETHECODENº8974ONTHEMEMORYNº1.
presentinthekeyboard(from0upto9).Forinstance,theaccess
codeNº8974couldbestoredonthedigit0,1,2,3,4,5,6,7,8
or9.Onlyonecodecouldbestoredperdigit,forthisreasonthe
maximumcodesnumberinmemoryis10.Toauthorizeanaccess
code,firstlyyouhavetoverifythatthemoduleisonoperations
controlmode(JP1closed),thenyouhavetoselectwhichdigitwill
storethecode,maintainingpressedthedigit“”youhaveto
pressthedigit(from0upto9)inwhichyouwishtostorethe
code.Then,the“Charge”Ledwilllightandanacousticsignalwill
beemitedtoindicatethatthecodeisstoredandthatyoucould
toreleasebothdigits.
*ON
Charge
Discharge
On
Off
Setup
Relay
JP1
Elements’situation
ofOperationsControl
onthemainPCB.
2ºTostoreintothememoryNº.1. Digit“*”andDigit“1”
3º.TointroducetheCode.Digits8,9,7,4and....
*
4º.Code’sconfirmation.Digits8,9,7,4and....
*
TofinishtheAccesscodeauthorisation. TocomebacktotheinitialstateoftheOperationsControl.
,
,
,
,
,
,
,
,
1ºDA-03onOperationsControlmode.JP1closed.
ON&OFFLedsalternativelylighting.
ON&OFFLedsAlternativelyIntermittent.
ChargeLedlighting.
ChargeLedlightingandONLedintermittent.
ChargeandONLedslighting.
1
8
8
9
9
7
7
4
4

ELECTRONIC CIRCUITS
OPERATING.
3
OPERATIONSCONTROL.Todenyaccesscodes. Accordingtothesamemodethantoautorize,theDA-03couldalso
denyoreraseupto10storedcodes.
Donotforgetthatcodesareindividuallystoredondigitsofthekeyboard,forthisreason,youhavetorememberthedigit
associatedtothecodethatyouwishtodenyorerase.
Todenyacode,firstlyyouhavetoverifythatthemoduleisonoperationscontrolmode(JP1closed),thenyouhaveto
selectwhichdigitwillstorethecode,maintainingpressedthedigit“#”youhavetopressthedigit(from0upto9)in
whichyouwishtoerasethecode.Then,the“Discharge”Ledwilllightandanacousticsignalwillbeemitedtoindicate
thatthecodehasbeenerasedandthatyoucouldtoreleasebothdigits.
Whenyouareintothememoryoftheselecteddigitthemodulewillwaitfortheeraseconfirmation.Todothatyouhave
torepeatthepreviousoperationpressing“#”andmemorydigitatthesametime.Ifyouhavecorrectlyproceed,an
acousticsignalwillbeemitedandDisharge&ONLedswilllight.Afterashorttime,themodulewillbebackatthe
Operationscontrolmode(ON&OFFledalternativelyintermittent)andthecodehasbeenerasedandthisdigitwillbe
availabletostorenewaccesscodes.
You coulddothisoperationastimeasyouwishifyouwaitthatthecircuitindicatesitsavailability(ON&OFFLedshave
toalternativelylight).
Ifyouwronglyproceedtodenyorerasecode,astowaitmoretimethanauthorisedfortheeraseconfirmationthecircuit
willemitanacousticsignalandtheOFFLedwillmomentarilylighttoindicatetheerror.
HOWTOERASEORDENYTHECODENº8974,ONTHEMEMORYNº1.
OPERATIONSCONTROL.RelayTiming. Therelayconnectioncouldbeadjustedaccordingtoaflip-floportimedmode
(formoreinformation,seetheOutputConnection-Loadparagraph).Ifyouselectthetimedmode,youhavetoprogram
themoduletoadjusttherelayconnectiontime,afteracorrectaccess.Youcouldprogramthetimebetween1and60,
selectingafterandthankstothecorrespondingswitchthetimingscale:SecondsorMinutes.Fromthefactory,the
moduleissuppliedwithatimingof5sec.
Toprogramtherelaytiming,astoauthorizeordenycodes,firstlyyouhavetoplacetheDA-03moduleonOperations
Controlmode(JP1closed).Then,youhavetopress“*”and“#”digitsatthesametime,DischargeandChargeledswill
lighttoindicatethatyouareintothememoryoftherelayandthatyoucouldrelasebothdigits.
Onceintherelaymemory,themodulewillwaitfortheintroductionofthewishedtiming.Pressdigitscorrespondingto
thewishedtiming(Presspreviouslythedigit“0”ifthewishedtimingisnferiorthan10)andthedigit“*”toconfirm.
Iftheoperationiscorrectlydone,anacousticsignalwillbeemitedandtheONLedwilllight.Afterashorttime,the
modulecomebacktotheinitialstateofOperationscontrol(ON&OFFLedsalternativelyintermittent).
ACCESSCONTROLWITHKEYBOARD
2º.ToerasethememoryNº1 ..Digits“#”and“1”
3º.ConfirmationtoerasethememoryNº1.Digits“#”and“1”
1ºDA-03onOperationsControlmode.JP1closed.
ON&OFFLedsAlternativelyLighting.
DischargeLedlightingandONLedIntermittent
DischargeandONledslighting
1
1
Tofinishtodenytheaccesscode.Tocomebacktotheinitialstateofoperationscontrol
ON&OFFLedsalternativelyIntermittent

DOMOTIC
4
OPERATING.
Tochangeagaintherelaytiming,repeatthisprocess,awaitingthatthemoduleindicatesitsavailability(ON&OFFLeds
alternativelyintermittent).
Ifyouwronglyproceed,astowaitmoretimethanauthorisedforthedatainsertion,ortopresswrongdigits,ortodigita
numbersuperiorthan60,thecircuitwillemitanacousticsignalandtheOFFLedwillmomentarilylighttoindicatethe
error.
HOWTOADJUSTARELAYTIMING:9sec./min.
COMMONOPERATINGMODE. Thankstothecommonoperatingmode,theDA-03modulewillexclusivelyoperateas
astandardaccesscontrol.Itwillcomparetheinsertedcodewiththestoredcodesandauthorizeordenyaccordingtothe
situation.Onthismode,youcouldnotdoneauthorization,denyorrelaytimingoperations.
ToplacetheDa-03oncommonoperatingmode,youhavetoopenordesoldbothterminalsoftheJP1Jumperand
removeit.Seetheschedule.WhentheJP1jumperisopen,ledsofthecircuitwillbemaitainedlightoff.Then,themodule
willwaitforanyaccesscode.
Toinsertthecode,youhavetoproceedasfollowing:firstlyintroducethecode,digitafterdigit.Forinstnaceifyouwishto
insertthecodeNº8974,youhavetopressthe8,then9,7,andattheendthedigitNº4.Toconfirmyouhavetopressthe
digit“*”.
Ifthecodehasbeencorrectlyinserted,andthisonewasalreadystoredinamemory,theDA-03modulewillemitasignal
toconfirmandtheONLedwilllightconnectingtherelay.
Ifthecodewasnotstoredinthememory,oriftherewasamistake,themodulewillemitasignalandOFFLedwillshortly
light;theoutputwon’tbeconnected.
Thecircuitaccepttill5consecutivetrials.Afterthesetrials,themodulewillbeautomaticallyblocked,impedingany
operationduring5minutesortillyoudisconnectthepowersupply..
Afteracorrectcode,previouswrongtrialsareeliminatedtoavoidanyaccumulation.Then,afterthe5minutesofauto-
blockingorafterresettingthemodulethemodulewillalsoeliminatewrongtrialsandcomebacktoitsnormaloperating
state.
Betweenaccesscodesintroductions,youhavetowaitONorOFFledsarelightoff.Iftherelayisconnected,forinstance,
theONledwilllightingtilltheoutputisdisconnected.
Ref.Full9928
2º.TohaveaccesstotheRelaymemory .Digits“*”and“#”.
3º.ToinsertTiming.Digits“0”,“9”and“.
*”
1ºDA-03onOperationControlmode.JP1closed
ON&OFFLedsalternativelyIntermittent
ChargeandDischargeLedslighting
Charge,DischargeandOnLedslighting
Toleavetherelay’smemory .TocomebacktotheinitialstateoftheOperationsControl.
ON&OFFLedsalternativelyintermittent
0, ,
9
JumpernotClosed
(Open).
Jumper
Closed JPPiece

ELECTRONIC CIRCUITS
5
OUTPUTCONNECTION.LOAD.
Común
(NA)NormalmenteAbierto
(NC)NormalmenteCerrado
Aparato,
Carga.
INFORMATIONABOUTTHEOUTPUT. Duringtheoperatingmodeandaccordingtoitsload,itcouldhappena
fluctuationoranincorrectworkingofthe
output.Insuchcase,youhavetoinstallan
anti-sparkcircuitbetweenbothcontactsof
theusedrelay,asitisindicatedonthe
schedule. 100nF/400V.
471/2W.?
AlimentacióndelaCarga.
OUTPUTCONFIGURATION. Aswehavepreviouslycommunicatedyou,theDA-03outputcouldbeadjustedaccording
toFlip-FloporTimedmode.TheFlip-Flopmode,whenthecodeiscorrect,willmaintainconnectedtherelaytillyoupress
theFlip-Floppushbutton.TheTimedmodewillmaintainconnectedtherelayduringtheadjustedtime.
ToconfiguratethemoduleontheFlip-Flopmode,youhavetoplacetheswitchNº2ofthe“SetupRelay”onONposition.
Toconfiguratetheoutputontimedmode,placethe switchNº2onOFFposition.Seeschedulehereafter.
TIMEDOUTPUT..Ifyouconfiguratetheoutputontimedmode,themoduleofferthepossibilitytousetwodifferent
scales,secondsorminutes.Forinstance,ifyouhaveinsertedthenumber9,thisnumbercouldbeinsecondsorminutes
scaleaccordingtoyourneeds.
Toselectthesecondssacle,youhavetoplacetheswitchNº1ofthe“SetupRelay”onOFFposition.Toselecttheminutes
scale,placetheswitchNº1onONposition.Seetheschedulehereafter.
OUTPUTCONNECTION. TheDA-03outputiscontrolledbyarelay,andacceptanydeviceupto5A.Therelayhave
threeoutputterminals:Thenormallyopenquiescent(NO),thenormallyclosedquiescent(NC)andthecommon.
ThismechanismoperatelikeaswitchwithtwoterminalsNOandCommon.Fortheinversefunctionyouhavetousethe
NCandCommon.Inthedrawinghereafter,youcouldseeatypicalconnectionwitha12VD.Cand230VA.Cdevices.
ACCESSCONTROLWITHKEYBOARD
ON ON
Setup
Relay
Setup
Relay
Timed/Flip-Flop. Timed/Flip-Flop.
RelayconfiguredwithTimedoutput.
ToconfiguratetheTimedoutput
onSecondsscale
RelayconfiguredwithFlip-Flopoutput
ToconfiguratetheTmedoutput
onMinutesscale
Sec./Min.
ON
Setup
Relay Timed/Flip-Flop.
Sec./Min. ON
Setup
Relay Timed/Flip-Flop.
Sec./Min.
Sec./Min.
220V.AC.CONNECTION12V.DC.CONNECTON
12V.DC
Common Common
(NO)NormallyOpen (NO)NormallyOpen
(NC)NormallyClosed (NC)NormallyClosed
Load,
Device
Load,
Device
220V.AC.

DOMOTIC
Ifyouhaveanydoubt,youcouldcontactyourwholesalerorourTechnicalDepartment.
-ViaE-Mail,P.OBox23455-08080BARCELONA-SPAIN.sat@cebek.com|bymail
TECHNICALCONSULTATIONS.
6
Allthemodule’sCEBEKhaveinthecnical
repairing,andsparesfromthedateofbuy.
3yearsoftotalwarranty
CEBEKistrademakeofFADISELS.L.morethan300module’sareavaibleinstock
foranypurposeorvisitourWeb.requestourCATALOGUE,
Http://www.cebek.com
ACOUSTICSIGNAL.
ACOUSTICSIGNAL. Ifyouwish,youcouldcanceltheacousticsignal,toavoidasignalanswerforeachoperating
options.Todothat,youhavetodesoldoropenterminalsoftheJP2jumper,removingtheJPpiecesuppliedwiththe
module.IfafteryouwishtouseagaintheacousticsignalyouonlyhavetoconnectJP2contacts.
Ref.Full9928
JP2OpenJP2Closed
AcousticSignalActivated AcousticSignalCancelled
GENERALWIRINGMAP.
Module
DA-03
NO
In
Flip-Flop
PushButton
NC
JP2
Acoustic
Signal
PowerSupply
RelayOutput
230V.AC.Mains
Mains
Switch
250mA.
Fuse
Led
Module
FE-2
TRANSFORMER.
FE-2
0
0
15 230
Common
Communication
withtheKeyboardPCB
ON
Charge
Discharge
On
Off
Setup
Relay
JP1