CEBEK DA-03 User manual

ELECTRONIC CIRCUITS
ACCESSCONTROLWITHKEYBOARD
TheDA-03modulewillallowtocontroltheaccessthankstoakeyboardanyplaceordevice.Youcouldinsertupto10
differentcodes(composedby4numberseachcode)whichwillbestoredinmemoryevenifyoustoptosupplythe
module.Itallowstoauthorizeanddenycodesandoffersarelayoutput.Theoutputcouldbeflip-floportimedtypes
withtimesadjustablebetween1and60sec.Or1and60minutes.
Itincludessignalleds,acousticsignal,keyboardandconnectionterminals.
OPERATING.
TECHNICALCHARACTERISTICS.
Voltage............................................................................................ 12V.DC.
MinimumConsumpitono................................................................10mA.
MaximumConsumption.................................................................60mA.
Relaytiming.....................................................................................Between1and60sec./min.
MaximumLoadtotherelay.............................................................5A.
Maximumdifferentcodes................................................................10.
Maximumtrialsbeforeauto-blocking..............................................5.
Maximumtimeonauto-blockngstate..........................................5minutes.
CircuitSizes......................................................................................90x70x30mm.
KeyboardsizeswithcommunicationPCB........................................76x51x20mm.
Keyboradsizes................................................................................64x51x12mm.
Comunicationcablelength.............................................................150mm.
1
POWERSUPPLY.
OPERATING.
Doneverdesold,separateormakelongerthecommunicationcableinstalledbetwenthePCBandthe
keyboard.
The
youhavetoproceed
accordingtofollowinginstructions:
-
Ifyoudonotrespectthispoint,themodulecouldbedamagedandthewarrantycancelled.
-Installthemoduleonanenclosurecorrectlyventilated.Ifyouhavetoinstallthemoduleoutside,useawatertight
enclosurewithaminimuminteriorspacetoallowstothemoduletodissipateheatwithoutanyproblemduringits
operating.
-Then,youhavetoprotecttheDA-03moduleagainstbadweather,excessivehumidityaswellasagainstdevicesor
apparatusgeneratingindustrialparasitesascoils,motors,neons,etc..
DA-03circuithadtobesuppliedbya12VDCpowersupplycorrectlyfiltered.Werecommendedyouthe
FE-2powersupplywhichhasbeendevelopedtoperfectlyanswertothecircuitneeds.Installafuseandaswitchhasiti
sindicatedontheschedule.Botharenecessaryforthemodule’sprotectionaswellasforyourownsafety,asitisrequiredbyteh
“CE”regulations.Connectthepositiveofthepowersupplytothepositiveterminalindicatedinthewiringmap,then connect
thenegativeofthepowersupplytothenegativeterminalindicatedinthecircuit..
Themoduleoperatingcouldbedividedaccordingtwoparts(orconcepts):anditsuse
in.
Verifythattheassemblyiscorrect
Operationscontrol
commonwork
Beforetoexplaintheoperationscontroloritsuseinstandardway,INFORMATIONABOUTTHEDA-03.
OPERATIONSCONTROL. Thankstotheoperationscontrolyoucouldauthorizeanddenyaccesscodeaswellasprogram
relaytiming.Toactivatetheopetaionscontrolmode,youhavetoconnect,closeorshort-circuitbothterminalsoftheJP1
jumperusingtheJPpiecesuppliedwiththemodule.Seethecorrespondingschedule.
WhentheDA-03isonthismode,themodulecouldnotbeusedasaccesscontrol,andonlyacceptoperationscontrol
management.
JumpernotClosed
(Open)
Jumper
Closed
JPPiece

DOMOTIC Ref.Full9928
2
OPERATING.
AssoonastheJP1Jumperisclosed,bothLedsONandOFFwillintermittentlylighttoindicatethattheOperations
Controlmodeisactivated.
Accesscodesarecomposedby4numbers(from0upto9)and
youcouldstoreinmemoryamaximumof10differentcodes.Thetenmemoriesallowingtostorecodesarethetendigits
OPERATIONSCONTROL.Toauthorizeaccesscodes.
Adigitcouldnotstoretwodifferentaccesscode;youhavetopreviouslydenytheanteriorcode.Ifyoudonotdenythe
anteriorcode,theOFFledwilllightandanacousticsignalwillbeemitedtoindicatethemistake.
Whenyouareintothememoryoftheselecteddigit(Chargeledlighting),youhavetointroducethecodecomposedby4
digitusingthekeyboardandpressingthedigit“”.Ifyouhavecorrectlydonetheoperation,themodulewillrequireyouto
confirmthecodetodefinitivelystoreit,maintainingthe“charge”ledlightingandONledintermittent.Thenintroduce
againthecodeandpressthedigit“”.Finally,andifyouhavecorrectlyproceed,anacousticsignalwillbeemitedand
Charge&ONLedswilllight.Afterashorttime,themodulewillbebackattheOperationscontrolmode(ON&OFFled
alternativelyintermittent)andthecodehasbeencorrectlystored.Youhavetodothisoperationforeachaccesscodethat
youneedtillamaximumof10codes.
Ifyouwronglyproceedtoauthorizeacode,astowaitmoretimethanauthorisedforthecodeconfirmation,orto
introducemoreorlessthan4digit,thecircuitwillemitanacousticsignalandtheOFFLedwillmomentarilylighttoindicate
theerror.
Eachtimeyoufinishacontroloperationastoauthorizeanaccesscode,youhavetowaitthatthecircuitindicatesyou (ON
&OFFLedshavetoalternativelylight)thepossibilitytoinsertanewcode.
*
*
HOWTOAUTHORISETHECODENº8974ONTHEMEMORYNº1.
presentinthekeyboard(from0upto9).Forinstance,theaccess
codeNº8974couldbestoredonthedigit0,1,2,3,4,5,6,7,8
or9.Onlyonecodecouldbestoredperdigit,forthisreasonthe
maximumcodesnumberinmemoryis10.Toauthorizeanaccess
code,firstlyyouhavetoverifythatthemoduleisonoperations
controlmode(JP1closed),thenyouhavetoselectwhichdigitwill
storethecode,maintainingpressedthedigit“”youhaveto
pressthedigit(from0upto9)inwhichyouwishtostorethe
code.Then,the“Charge”Ledwilllightandanacousticsignalwill
beemitedtoindicatethatthecodeisstoredandthatyoucould
toreleasebothdigits.
*ON
Charge
Discharge
On
Off
Setup
Relay
JP1
Elements’situation
ofOperationsControl
onthemainPCB.
2ºTostoreintothememoryNº.1. Digit“*”andDigit“1”
3º.TointroducetheCode.Digits8,9,7,4and....
*
4º.Code’sconfirmation.Digits8,9,7,4and....
*
TofinishtheAccesscodeauthorisation. TocomebacktotheinitialstateoftheOperationsControl.
,
,
,
,
,
,
,
,
1ºDA-03onOperationsControlmode.JP1closed.
ON&OFFLedsalternativelylighting.
ON&OFFLedsAlternativelyIntermittent.
ChargeLedlighting.
ChargeLedlightingandONLedintermittent.
ChargeandONLedslighting.
1
8
8
9
9
7
7
4
4

ELECTRONIC CIRCUITS
OPERATING.
3
OPERATIONSCONTROL.Todenyaccesscodes. Accordingtothesamemodethantoautorize,theDA-03couldalso
denyoreraseupto10storedcodes.
Donotforgetthatcodesareindividuallystoredondigitsofthekeyboard,forthisreason,youhavetorememberthedigit
associatedtothecodethatyouwishtodenyorerase.
Todenyacode,firstlyyouhavetoverifythatthemoduleisonoperationscontrolmode(JP1closed),thenyouhaveto
selectwhichdigitwillstorethecode,maintainingpressedthedigit“#”youhavetopressthedigit(from0upto9)in
whichyouwishtoerasethecode.Then,the“Discharge”Ledwilllightandanacousticsignalwillbeemitedtoindicate
thatthecodehasbeenerasedandthatyoucouldtoreleasebothdigits.
Whenyouareintothememoryoftheselecteddigitthemodulewillwaitfortheeraseconfirmation.Todothatyouhave
torepeatthepreviousoperationpressing“#”andmemorydigitatthesametime.Ifyouhavecorrectlyproceed,an
acousticsignalwillbeemitedandDisharge&ONLedswilllight.Afterashorttime,themodulewillbebackatthe
Operationscontrolmode(ON&OFFledalternativelyintermittent)andthecodehasbeenerasedandthisdigitwillbe
availabletostorenewaccesscodes.
You coulddothisoperationastimeasyouwishifyouwaitthatthecircuitindicatesitsavailability(ON&OFFLedshave
toalternativelylight).
Ifyouwronglyproceedtodenyorerasecode,astowaitmoretimethanauthorisedfortheeraseconfirmationthecircuit
willemitanacousticsignalandtheOFFLedwillmomentarilylighttoindicatetheerror.
HOWTOERASEORDENYTHECODENº8974,ONTHEMEMORYNº1.
OPERATIONSCONTROL.RelayTiming. Therelayconnectioncouldbeadjustedaccordingtoaflip-floportimedmode
(formoreinformation,seetheOutputConnection-Loadparagraph).Ifyouselectthetimedmode,youhavetoprogram
themoduletoadjusttherelayconnectiontime,afteracorrectaccess.Youcouldprogramthetimebetween1and60,
selectingafterandthankstothecorrespondingswitchthetimingscale:SecondsorMinutes.Fromthefactory,the
moduleissuppliedwithatimingof5sec.
Toprogramtherelaytiming,astoauthorizeordenycodes,firstlyyouhavetoplacetheDA-03moduleonOperations
Controlmode(JP1closed).Then,youhavetopress“*”and“#”digitsatthesametime,DischargeandChargeledswill
lighttoindicatethatyouareintothememoryoftherelayandthatyoucouldrelasebothdigits.
Onceintherelaymemory,themodulewillwaitfortheintroductionofthewishedtiming.Pressdigitscorrespondingto
thewishedtiming(Presspreviouslythedigit“0”ifthewishedtimingisnferiorthan10)andthedigit“*”toconfirm.
Iftheoperationiscorrectlydone,anacousticsignalwillbeemitedandtheONLedwilllight.Afterashorttime,the
modulecomebacktotheinitialstateofOperationscontrol(ON&OFFLedsalternativelyintermittent).
ACCESSCONTROLWITHKEYBOARD
2º.ToerasethememoryNº1 ..Digits“#”and“1”
3º.ConfirmationtoerasethememoryNº1.Digits“#”and“1”
1ºDA-03onOperationsControlmode.JP1closed.
ON&OFFLedsAlternativelyLighting.
DischargeLedlightingandONLedIntermittent
DischargeandONledslighting
1
1
Tofinishtodenytheaccesscode.Tocomebacktotheinitialstateofoperationscontrol
ON&OFFLedsalternativelyIntermittent

DOMOTIC
4
OPERATING.
Tochangeagaintherelaytiming,repeatthisprocess,awaitingthatthemoduleindicatesitsavailability(ON&OFFLeds
alternativelyintermittent).
Ifyouwronglyproceed,astowaitmoretimethanauthorisedforthedatainsertion,ortopresswrongdigits,ortodigita
numbersuperiorthan60,thecircuitwillemitanacousticsignalandtheOFFLedwillmomentarilylighttoindicatethe
error.
HOWTOADJUSTARELAYTIMING:9sec./min.
COMMONOPERATINGMODE. Thankstothecommonoperatingmode,theDA-03modulewillexclusivelyoperateas
astandardaccesscontrol.Itwillcomparetheinsertedcodewiththestoredcodesandauthorizeordenyaccordingtothe
situation.Onthismode,youcouldnotdoneauthorization,denyorrelaytimingoperations.
ToplacetheDa-03oncommonoperatingmode,youhavetoopenordesoldbothterminalsoftheJP1Jumperand
removeit.Seetheschedule.WhentheJP1jumperisopen,ledsofthecircuitwillbemaitainedlightoff.Then,themodule
willwaitforanyaccesscode.
Toinsertthecode,youhavetoproceedasfollowing:firstlyintroducethecode,digitafterdigit.Forinstnaceifyouwishto
insertthecodeNº8974,youhavetopressthe8,then9,7,andattheendthedigitNº4.Toconfirmyouhavetopressthe
digit“*”.
Ifthecodehasbeencorrectlyinserted,andthisonewasalreadystoredinamemory,theDA-03modulewillemitasignal
toconfirmandtheONLedwilllightconnectingtherelay.
Ifthecodewasnotstoredinthememory,oriftherewasamistake,themodulewillemitasignalandOFFLedwillshortly
light;theoutputwon’tbeconnected.
Thecircuitaccepttill5consecutivetrials.Afterthesetrials,themodulewillbeautomaticallyblocked,impedingany
operationduring5minutesortillyoudisconnectthepowersupply..
Afteracorrectcode,previouswrongtrialsareeliminatedtoavoidanyaccumulation.Then,afterthe5minutesofauto-
blockingorafterresettingthemodulethemodulewillalsoeliminatewrongtrialsandcomebacktoitsnormaloperating
state.
Betweenaccesscodesintroductions,youhavetowaitONorOFFledsarelightoff.Iftherelayisconnected,forinstance,
theONledwilllightingtilltheoutputisdisconnected.
Ref.Full9928
2º.TohaveaccesstotheRelaymemory .Digits“*”and“#”.
3º.ToinsertTiming.Digits“0”,“9”and“.
*”
1ºDA-03onOperationControlmode.JP1closed
ON&OFFLedsalternativelyIntermittent
ChargeandDischargeLedslighting
Charge,DischargeandOnLedslighting
Toleavetherelay’smemory .TocomebacktotheinitialstateoftheOperationsControl.
ON&OFFLedsalternativelyintermittent
0, ,
9
JumpernotClosed
(Open).
Jumper
Closed JPPiece

ELECTRONIC CIRCUITS
5
OUTPUTCONNECTION.LOAD.
Común
(NA)NormalmenteAbierto
(NC)NormalmenteCerrado
Aparato,
Carga.
INFORMATIONABOUTTHEOUTPUT. Duringtheoperatingmodeandaccordingtoitsload,itcouldhappena
fluctuationoranincorrectworkingofthe
output.Insuchcase,youhavetoinstallan
anti-sparkcircuitbetweenbothcontactsof
theusedrelay,asitisindicatedonthe
schedule. 100nF/400V.
471/2W.?
AlimentacióndelaCarga.
OUTPUTCONFIGURATION. Aswehavepreviouslycommunicatedyou,theDA-03outputcouldbeadjustedaccording
toFlip-FloporTimedmode.TheFlip-Flopmode,whenthecodeiscorrect,willmaintainconnectedtherelaytillyoupress
theFlip-Floppushbutton.TheTimedmodewillmaintainconnectedtherelayduringtheadjustedtime.
ToconfiguratethemoduleontheFlip-Flopmode,youhavetoplacetheswitchNº2ofthe“SetupRelay”onONposition.
Toconfiguratetheoutputontimedmode,placethe switchNº2onOFFposition.Seeschedulehereafter.
TIMEDOUTPUT..Ifyouconfiguratetheoutputontimedmode,themoduleofferthepossibilitytousetwodifferent
scales,secondsorminutes.Forinstance,ifyouhaveinsertedthenumber9,thisnumbercouldbeinsecondsorminutes
scaleaccordingtoyourneeds.
Toselectthesecondssacle,youhavetoplacetheswitchNº1ofthe“SetupRelay”onOFFposition.Toselecttheminutes
scale,placetheswitchNº1onONposition.Seetheschedulehereafter.
OUTPUTCONNECTION. TheDA-03outputiscontrolledbyarelay,andacceptanydeviceupto5A.Therelayhave
threeoutputterminals:Thenormallyopenquiescent(NO),thenormallyclosedquiescent(NC)andthecommon.
ThismechanismoperatelikeaswitchwithtwoterminalsNOandCommon.Fortheinversefunctionyouhavetousethe
NCandCommon.Inthedrawinghereafter,youcouldseeatypicalconnectionwitha12VD.Cand230VA.Cdevices.
ACCESSCONTROLWITHKEYBOARD
ON ON
Setup
Relay
Setup
Relay
Timed/Flip-Flop. Timed/Flip-Flop.
RelayconfiguredwithTimedoutput.
ToconfiguratetheTimedoutput
onSecondsscale
RelayconfiguredwithFlip-Flopoutput
ToconfiguratetheTmedoutput
onMinutesscale
Sec./Min.
ON
Setup
Relay Timed/Flip-Flop.
Sec./Min. ON
Setup
Relay Timed/Flip-Flop.
Sec./Min.
Sec./Min.
220V.AC.CONNECTION12V.DC.CONNECTON
12V.DC
Common Common
(NO)NormallyOpen (NO)NormallyOpen
(NC)NormallyClosed (NC)NormallyClosed
Load,
Device
Load,
Device
220V.AC.

DOMOTIC
Ifyouhaveanydoubt,youcouldcontactyourwholesalerorourTechnicalDepartment.
-ViaE-Mail,P.OBox23455-08080BARCELONA-SPAIN.sat@cebek.com|bymail
TECHNICALCONSULTATIONS.
6
Allthemodule’sCEBEKhaveinthecnical
repairing,andsparesfromthedateofbuy.
3yearsoftotalwarranty
CEBEKistrademakeofFADISELS.L.morethan300module’sareavaibleinstock
foranypurposeorvisitourWeb.requestourCATALOGUE,
Http://www.cebek.com
ACOUSTICSIGNAL.
ACOUSTICSIGNAL. Ifyouwish,youcouldcanceltheacousticsignal,toavoidasignalanswerforeachoperating
options.Todothat,youhavetodesoldoropenterminalsoftheJP2jumper,removingtheJPpiecesuppliedwiththe
module.IfafteryouwishtouseagaintheacousticsignalyouonlyhavetoconnectJP2contacts.
Ref.Full9928
JP2OpenJP2Closed
AcousticSignalActivated AcousticSignalCancelled
GENERALWIRINGMAP.
Module
DA-03
NO
In
Flip-Flop
PushButton
NC
JP2
Acoustic
Signal
PowerSupply
RelayOutput
230V.AC.Mains
Mains
Switch
250mA.
Fuse
Led
Module
FE-2
TRANSFORMER.
FE-2
0
0
15 230
Common
Communication
withtheKeyboardPCB
ON
Charge
Discharge
On
Off
Setup
Relay
JP1
Table of contents
Other CEBEK IP Access Controllers manuals
Popular IP Access Controllers manuals by other brands

Delta Controls
Delta Controls ASM-24 Installation & Application Guide

Satel
Satel INT-SCR Quick installation guide

H3C
H3C WBC580 G2 Installation, quick start

FingerTec
FingerTec AC100C quick start guide

Coppernic
Coppernic C-One2 Quick Start and Regulatory Guide

Simons Voss Technologies
Simons Voss Technologies MobileKey manual