INSTRUCTION MANUAL
POCKET AUTORANGING DMM
Hz
AC
DC
Auto REL
K
BAT
DIGITAL
MULTIMETER
/ //
Safety
International Safety Symbols
This symbol, adjacent to another symbol or
terminal, indicates the user must refer to the manual
for further information.
This symbol, adjacent to a terminal, indicates that,
under normal use, hazardous voltages may be
present.
Double insulation
Safety Precautions
1. Improper use of this meter can cause damage, shock, injury or
death. Read and understand this users manual before
operating the meter.
2. Make sure any covers or battery doors are properly closed and
secured.
3. Always disconnect the test leads from any voltage source
before replacing the battery or fuses.
4. Do not exceed the maximum rated input limits.
5. Use great care when making measurements if the voltages are
greater than 25VAC rms or 35VDC. These voltages are
considered a shock hazard.
6. Always discharge capacitors and remove power from the
device under test before performing Capacitance, Diode,
Resistance or Continuity tests.
7. Remove the battery from the meter if the meter is to be stored
for long periods.
Description
Meter Description
1. 3 3/4 Digit (4000 count)
2. RELATIVE button
3. SELECT button
4. DATA HOLD button
5. Hz/DUTY button
6. Function switch
7. Plastic case
8. Test leads
Specifications
Electrical Specifications
Function
Range
Accuracy
DC Voltage
400.0mV
±(0.7% rdg + 3d)
4.000V, 40.00V,
±(1.0% rdg + 3d)
400.0V, 500V
±(1.3% rdg + 3d)
AC Voltage
50-60Hz
4.000V, 40.00V
±(1.0% rdg + 10d)
400.0V, 500V ±
(2.3% rdg + 5d)
Resistance
400.0Ω4.000kΩ,
40.00kΩ, 400.0kΩ
±(2.0% rdg + 5d)
4.000MΩ±(5.0% rdg + 5d)
40.00MΩ±(10.0% rdg + 5d)
Capacitance
4.000nF
±
(5.0% rdg + 0.3 nF)
40.00nF
±(5.0% rdg + 30d)
400.0nF ±
(3.0% rdg + 15d)
4.000µF, 40.00µF,
200.0µF
±(10.0% rdg + 15d)
Frequency
9.999Hz, 99.99Hz,
999.9Hz, 9.999kHz,
99.99kHz, 999.9kHz,
10MHz
±(2.0% rdg + 5d)
Duty Cycle
0.1-99%
±
(2.0% rdg + 5d)
DC Current
40.00mA
±(2.0% rdg + 5d)
200.0mA
AC Current
50-60Hz
40.00mA
±(2.5% rdg + 10d)
200.0mA
Max input voltage 500V AC/DC
Input Sensitivity, 10Vrms min. <9.999KHz
(Frequency Ranges) 40Vrms min. >99.99KHz
Diode Test Test current 1mA max., open circuit voltage
of 1.5V typical
Continuity Check Audible signal if the resistance is < 60Ω
Display 4000 count 3 ¾ digit LCD
Over range indication LCD displays “OL”
Polarity Minus (-) sign for negative polarity.
Low Battery Indication “BAT” symbol indicates low battery
condition.
Fuse mA range; 0.4A/250V fast acting resettable
fuse
Battery CR2032 3V Lithium
Operating Temperature 32oF to 104oF (0oC to 40oC)
Storage Temperature 14oF to 122oF (-10oC to 50oC)
Weight 1.7oz (50g)
Size 4.25x2.2x.5” (108x56x11.5mm)
Standard IEC61010 CAT II 500V Pollution degree
II, CE Approved
/ /
/
7
MULTI METER
AC
DIGITAL
DC
Auto
Hz
REL BAT
K
8
Operation
AC/ DC Voltage Measurement
1. Set the function switch to the “AC/DCV” position .
2. Press the “SESECT” button to measure DCV or ACV.
3. Touch the test probe tips to the circuit under test. Be sure to
observe the correct polarity (red lead to positive, black lead to
negative).
4. Read the voltage on the display
Resistance/Continuity Measurement
WARNING: To avoid electric shock, disconnect power to the unit
under test and discharge all capacitors before taking any
resistance measurements. Remove the batteries and unplug the
line cords. Never measure continuity on circuits or wires that
have voltage on them.
1. Set the function switch to the “ Ω •))) ” position.
2. Connect the test leads to the circuit to be measured.
3. Read the value on the display.
4. For Continuity tests, press the SELECT button until the “•)))“
symbol appears in the display.
5. If the resistance is less than 60 ohms, an audible tone
will sound.
Capacitance Measurement
WARNING: To avoid electric shock, disconnect power to the unit
under test and discharge all capacitors before taking any
capacitance measurements. Remove the batteries and unplug
the line cords. Never measure continuity on circuits or wires that
have voltage on them.
1. Set the function switch to the “ Ω •))) ” position.
2. Press the SELECT button until “nF” appears in the display.
3. Press the RELATIVE button to zero the display
4. Connect the test leads to the capacitor to be measured.
5. Read the value on the display.
Diode Test
WARNING: To avoid electric shock, do not test any diode that
has voltage on it.
1. Set the function switch to “ Ω •))) “position.
2. Press the SELECT button once to enter Diode Test. The “ “
symbol will appear in the display.
3. Touch the test probe tips to the diode or semiconductor junction
you wish to test. Note the meter reading.
4. Reverse the test lead polarity by reversing the red and black leads.
Note this reading.
5. The diode or junction can be evaluated as follows:
A. If one reading shows a value and the other reading shows OL,
the diode is good.
B. If both readings show OL, the device is open.
C. If both readings are very small, or 0, the device is shorted
AC/DC CURRENT MEASUREMENTS
1. For current measurements up to 400mA AC/DC, set the
function switch to the mA position.
2. Press the MODE button to indicate “AC” or “DC” on the
display.
3. Remove power from the circuit under test, then open up the
circuit at the point where you wish to measure current.
4. Touch the black test probe tip to the negative side of the
circuit.
Touch the red test probe tip to the positive side of the circuit.
5. Apply power to the circuit.
6. Read the current in the display.
Frequency/Duty Cycle Measurement
1. Set the function switch to the “HZ/DUTY” position.
2. Press the Hz/DUTY button once to display Duty Cycle %. Pressing
the button again will toggle the display to frequency (Hz).
3. Touch the test probe tips to the circuit under test. Be sure to
observe the correct polarity (red lead to positive, black lead to
negative).
4. Read the value on the display.
Features
Relative Button
The relative measurement feature allows you to make measurements
relative to a stored reference value. A reference voltage can be
stored and measurements made in comparison to that value. The
displayed value is the difference between the reference value and the
measured value.
1. Perform the measurement as described in the operating
instructions.
2. Press the RELATIVE button to store the reading in the display and
the "REL" indicator will appear on the display.
3. The display will now indicate the difference between the stored
value and the measured value.
4. Press the RELATIVE button to exit the relative mode.
Note: The Relative function does not operate in the Frequency
function.
Data Hold Button
The Data Hold function allows the meter to “freeze” a measurement
for later reference
1. Press the “DATA HOLD” button to “freeze” the display, the
“HOLD” indicator will appear.
2. Press the “DATA HOLD” button to return to normal operation.
Auto Power Off
1. To save power, the display automatically turns off in 30 minutes.
2. Press the SELECT button to turn display back on.
3. To cancel Auto Power Off, set the function switch to the off
position. Hold down the SELECT button and turn the function
switch to the desired position and release the SELECT button after
3 seconds.
Maintenance
WARNING: Disconnect the test leads from any source of voltage
before removing the back cover or the battery/fuse door. Do not
operate your meter until the rear housing is in place and fastened
securely.
RESETTABLE FUSE
1, The fast acting, 0.4 A/250V resettable fuse will open if the current
limits of the meter are exceeded.
2, The fuse will automatically reset itself when the suspect current is
removed from the meter’s input
Replacing the Battery
1. Remove the rubber holster (if in place)
2. Remove Philips head screw and lift off the rear housing of the
meter.
3. Replace old battery with fresh CR2032 type button battery.
4. Replace the rear cover and secure the screw.

Other CEM Multimeter manuals

CEM 9915 User manual

CEM

CEM 9915 User manual

CEM LA-1015 User manual

CEM

CEM LA-1015 User manual

CEM DT-9929 User manual

CEM

CEM DT-9929 User manual

CEM DT-9985 User manual

CEM

CEM DT-9985 User manual

CEM DT-9969 User manual

CEM

CEM DT-9969 User manual

CEM DT-111 User manual

CEM

CEM DT-111 User manual

CEM DT-102 User manual

CEM

CEM DT-102 User manual

CEM DT-9995 User manual

CEM

CEM DT-9995 User manual

CEM DT-6505 User manual

CEM

CEM DT-6505 User manual

CEM DT-9989 Reference guide

CEM

CEM DT-9989 Reference guide

CEM DT-912 User manual

CEM

CEM DT-912 User manual

CEM DT-932N User manual

CEM

CEM DT-932N User manual

CEM DT-9987 User manual

CEM

CEM DT-9987 User manual

Popular Multimeter manuals by other brands

Keithley DAQ6510 quick start guide

Keithley

Keithley DAQ6510 quick start guide

Delton 770E Operator's manual

Delton

Delton 770E Operator's manual

Conrad Electronic ME-42 operating instructions

Conrad Electronic

Conrad Electronic ME-42 operating instructions

RS PRO RS-927A instruction manual

RS PRO

RS PRO RS-927A instruction manual

Newtons4th PSM3750 NumetriQ Startup guide

Newtons4th

Newtons4th PSM3750 NumetriQ Startup guide

Major tech MTD30 Operation manual

Major tech

Major tech MTD30 Operation manual

Fluke 8808A datasheet

Fluke

Fluke 8808A datasheet

Brymen BM195 user manual

Brymen

Brymen BM195 user manual

Axio AX-155 instruction manual

Axio

Axio AX-155 instruction manual

Keysight U1271A Service guide

Keysight

Keysight U1271A Service guide

EXTOL PREMIUM 8831252 Translation of the original user manual

EXTOL PREMIUM

EXTOL PREMIUM 8831252 Translation of the original user manual

Gossen MetraWatt SECULIFE HIT MD Quick setup guide

Gossen MetraWatt

Gossen MetraWatt SECULIFE HIT MD Quick setup guide

Lutron Electronics LCR-9184 Operation manual

Lutron Electronics

Lutron Electronics LCR-9184 Operation manual

ELIT 624 manual

ELIT

ELIT 624 manual

Tenma 72-2600 manual

Tenma

Tenma 72-2600 manual

Meterman AM-37XRA user manual

Meterman

Meterman AM-37XRA user manual

REED ST-922 instruction manual

REED

REED ST-922 instruction manual

Wavetek Meterman 220 Operator's manual

Wavetek

Wavetek Meterman 220 Operator's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.