Charder MS7321 User manual

USER MANUAL
MS7321
Stand-on Floor Scale
Please keep the instruction manual at hand all the time for future reference.

Explanation of the Graphic Symbols
SN-T13000001
Designation of the serial number of every device,
applied at the device.(Number as an example)
“Please note the accompanying documents“
or “Observe operating instructions”
Identification of manufacturer of medical product
including address
“Electro-medical appliance“ with attachment for
type BF
Dispose of old appliances separately from your
household waste. Instead, take them to designated
collection points for electronics.
Carefully read this operation manual before setup
and
commissioning, even if you are already familiar with
Charder scales.
Manufacturing date
Lot number or batch number
Charder Electronic Co., Ltd.
No. 103, Guozhong Rd., Dali Dist.,
Taichung City, 412 Taiwan

Copyright Notice
Charder Electronic Co., Ltd.
No.103, Guozhong Rd., Dali Dist., Taichung City 41262 Taiwan
Tel: +886-4-2406 3766
Fax: +886-4-2406 5612
Website: www.chardermedical.com E-mail: info_cec@charder.com.tw
Copyright© Charder Electronic Co., Ltd. All rights reserved.
This user manual is protected by international copyright law. All content is
licensed, and usage is subject to written authorization from Charder
Electronic Co., Ltd. (hereinafter Charder) Charder is not liable for any
damage caused by a failure to adhere to requirements stated in this
manual. Charder reserves the right to correct misprints in the manual
without prior notice, and modify the exterior of the device for quality
purposes without customer consent.

CONTENTS
I. Safety Notes .......................................................................... 5
A. Precaution Symbols..............................................................5
B. General Information.............................................................5
II. Quick Guide.......................................................................... 8
A. Contents.............................................................................8
B. Inserting Batteries ...............................................................9
C. Unit Selection (kg/lb) ...........................................................9
III. Using Device ......................................................................10
IV. Troubleshooting..................................................................11
V. Product Specifications..........................................................13
A. Device Information ............................................................13

I. Safety Notes
A. Precaution Symbols
Warning
Identifies the possibility of serious injury or death
for the user if the device is mishandled, or safety
instructions are not followed.
Caution
Identifies the possibility of physical injury or device
damage if the device is mishandled, or safety
instructions are not followed.
The caution symbol indicates general precautions
that should be taken when using the device.
NOTE
Additional information regarding the operating
environment, conditions for installation, or special
conditions in usage.
Indicates actions that should not be performed.
B. General Information
Thank you for choosing this Charder Medical device. It is designed to be
easy and straightforward to operate, but if you encounter any problems
not addressed in this manual, please contact your local Charder service
partner.
Before beginning operation of the device, please read this user manual
carefully, and keep it in a safe place for reference. It contains important
instructions regarding installation, proper usage, and maintenance.
Caution
General Handling
This device is intended for indoor use only.
Do not place the device on slippery surfaces.
Caution

Injuries and Infections
For hygiene purposes, Charder recommends cleaning the measuring
platform after each measurement with a soft cloth and alcohol.
Ensure that the measuring platform is dry before usage.
Caution
Preventing Device Damage
Please contact your local Charder distributor for regular maintenance
and calibration.
This device does not contain any user-maintained parts. All
maintenance, technical inspections, and repairs should be conducted
by an authorized Charder service partner, using original Charder
accessories and spare parts. Charder is not liable for any damages
arising from improper maintenance or usage. Dismantlement of the
device will void the warranty.
Take care to make sure fluids do not enter the device, as they may
damage the internal electronics.
Switch off the device before disconnecting the power supply.
Do not place the device in direct sunlight, or in close proximity to an
intense heat source. Excessively high temperatures may damage the
internal electronics.
Strong cleaning agents can damage the measuring platform's
surface.
Caution
Disposal/Environmental
All batteries contain toxic compounds; batteries should be disposed
of via designated competent organizations. Batteries should not be
incinerated.
The optimum operating temperature for the scale is 0℃to +40℃;
although it will operate at higher and lower temperatures, battery
life will adversely be effected.
Warranty/Liability
If Charder is responsible for a fault or defect present upon receipt of
the unit, Charder shall either repair the fault, or supply a
replacement unit. Should the repairs or replacement delivery fail,
statutory provisions shall be valid. The period of warranty shall be
two years, beginning on the date of purchase. Please retain your
receipt as proof of purchase.

No responsibility shall be accepted for damage caused through any
of the following reasons: unsuitable or improper storage or use,
incorrect installation or commissioning by the owner or third parties,
natural wear and tear, changes or modifications, incorrect or
negligent handling, chemical, electrochemical, or electrical
interference, unless damage is attributable to negligence on the part
of Charder.
Disposal
This product is not to be treated as regular household waste, but
should be taken to a designated collection points for electronics.
Warning
Measurements for physically disabled persons.
Physically disabled persons should not attempt to take
measurements alone, but instead should have their caretakers assist
them in using the device.
Warning
Do not under any circumstances dismantle or alter the device, as this
could result in electric shock or injury as well as adversely affect the
precision of measurements.

II. Quick Guide
A. Contents
LCD
Unit switch
(kg/lb)
Reset button
(Contact distributor
before resetting)
Battery cover
Feet*4
Battery symbol
(low/depleted)

B. Inserting Batteries
1. Open the battery housing cover on bottom of device.
2. Insert batteries as indicated in battery compartment (AA*4)
Note: when depleted battery symbol appears, replace all four
batteries with new ones. Remove batteries from device before placing
into long-term storage (>3 months) to avoid device damage.
C. Unit Selection (kg/lb)
Select kg/lb when device is turned off.

III. Using Device
1. Place device on hard, flat, non-slippery surface.
NOTE: do not place device on soft surfaces (e.g. carpet, mats)
2. Step onto device. Device will automatically power-on and take weight
measurement.
NOTE: Remain still during measurement. Measure weight at the same
time (ideally morning) for consistency.

IV. Troubleshooting
Product Defects
Charder's warranty is effective for the original purchaser of this device,
subject to the terms and conditions listed in the Warranty Program &
Return Policy.
1. If Charder is responsible for a fault or defect present upon receipt of the
unit, Charder shall either repair the fault, or supply a replacement unit.
Should the repairs or replacement delivery fail, statutory provisions shall
be valid. The period of warranty shall be two years, beginning on the date
of purchase. Please retain your receipt as proof of purchase.
2. No responsibility shall be accepted for damage caused through any of
the following reasons: unsuitable or improper storage or use, incorrect
installation or commissioning by the owner or third parties, natural wear
and tear, changes or modifications, incorrect or negligent handling,
chemical, electrochemical, or electrical interference, unless damage is
attributable to negligence on the part of Charder.
If device is not covered under warranty, a service maintenance charge will
apply, plus cost of replacement parts.
Before contacting your local Charder distributor for repair service, we
recommend considering the following troubleshooting procedures:
Self-inspection
Device will not power on
Please confirm batteries are inserted.
If batteries are inserted, please confirm they have power
If batteries are inserted, please confirm they are inserted in the
correct direction.

Error Messages
Error Message
Reason
Action
Batteries are low
Replace batteries with new
ones before depletion.
Batteries are depleted.
Replace batteries with new
ones.
Movement during
measurement.
Do not move until
measurement is completed.
Device error.
Contact your distributor.
Weight exceeds capacity
Allowable weight range:
15-250kg (33-550lb)
Misalignment during
auto-calibration
Repeat measurement.
Function failure
Check batteries

V. Product Specifications
Device Information
Model
MS3721
Weight
Measurement
Capacity
15-100kg x 0.1kg
(33-220lb x 0.2lb)
100-250kg x 0.2kg
(220-550lb x 0.5lb)
Accuracy
15-40kg±0.4kg
(33-88lb±0.88lb)
40-250kg±1%
(88-550lb±1%)
IP
Classification
IP21
Dimensions
Device
415(W) x 360(D) x 41(H) mm
1 3/5”(H) x 16 1/3” (W) x 14 1/5”(D)
Weight
~3.5kg (7.7 lb) including batteries
Key Functions
On/Off, Zero, Print, BMI, Hold,
Pre-Tare, Tare, Clear, Enter, 0~9, M1-5
Power Supply
4 AA alkaline batteries
Operation Temperature &
Humidity 10℃~40℃(+50°F to +104°F)
15% / 85% RH
Standard Accessories
User manual x1, AA Batteries x4
(optional)
This device fulfills the provisions of EMC Directive 2004/108/EC

Manufactured by:
Charder Electronic Co., Ltd.
No.103, Guozhong Rd., Dali Dist.,
Taichung City, 412 Taiwan (R.O.C.)
CD-IN-00329 REV 004 03/2020
Other manuals for MS7321
1
Table of contents
Other Charder Scale manuals

Charder
Charder MS3400 User manual

Charder
Charder W320 User manual

Charder
Charder MS6001 User manual

Charder
Charder MS 5460 User manual

Charder
Charder MBF6000 User manual

Charder
Charder MS5410 User manual

Charder
Charder MS 2400 User manual

Charder
Charder MS4201 User manual

Charder
Charder MS 4971 User manual

Charder
Charder MS2510 Manual

Charder
Charder MS 5900 User manual

Charder
Charder MS21NEOV User manual

Charder
Charder MS4910 User manual

Charder
Charder MS 5460 User manual

Charder
Charder MS 2100 User manual

Charder
Charder MS4970 User manual

Charder
Charder MS 5900 User manual

Charder
Charder MS 3850 User manual

Charder
Charder R460 User manual

Charder
Charder MS5810 User manual