GSM SECURITY ALARM SYSTEM
PST-G11E
1
Introduction
Wireless GSM Burglar Alarm with voice prompt for commercial and home use is built on
leading microprocessor technology with advanced GSM digital signal processing power. It
is a highly integrated system of digital speech, mobile messages, multiple modes of
wireless coding, long-distance home appliances controlling, SMS Messages identification
and other technologies. When alarming, it will automatically notify users via mobile network
about the possible break-in using either voice calling or SMS messaging. It is stable,
reliable and safe. With its user-friendly design and without the need of fixed telephone
network, it can be widely used in different locations including shops, offices, villas,
residential estate, garage, warehouse, to name just a few. It is an ideal choice to protect
your properties and personnel safety.
Features
■ Work with GSM SIM card , and voice prompt ,easy of use .
■ Two groups of Scheduled Arming and Disarming function.each time disarmed you
can select the included period of time, eliminating of need of the manual procedure,
realizing the beauty of automatic controls.
■ Four wired zone, six wireless zone, can be set as AWAY, STAY, INTELLIGENT or
CLOSED types ,and each zone can be equipped with many accessories.
■ Using phone (cellular phone) or SMS Messages to configure and control the Panel
remotely.
■ Six groups of phone numbers for voice calling and three groups for SMS Messages,
10 seconds ISD automatic leaving message record
■ Telephone (phone) long-distance telephone control for arming, disarming,
monitoring, remote announcement.
■ One group of normally open signal output, which can be externally linked to electrical
appliances with alarming output.
■ Many built-in speeches, letting alarm receivers know the accurate alerting location
■ SMS Messages content from alarming Defense zone can be customized.
■ Wireless intelligent study coding, compatible with PT2262 normal encoding and a
million group encoding, convenient and flexible for adding or reducing
accessories.Maximum support 50 remote control and 50 sensors.
■ Telephone (phone) long-distance telecontrol for arming, disarming, monitoring,
talkbacking, shouting, and controlling appliances, etc.
■ EEPROM information protection, information never lost
■ Built-in Ni-Hi rechargeable battery and automatically switchable upon power failure,
and notification will be sent via SMS.
■Panel integrated with either dual-band, triple-band, quad-band GSM/GPRS industrial
graded module, stable and reliable.
2.1 System Components and Usage
ARM
The system is at a fully ready status where all detectors are activated in a working state,
when the some events ( burglar, fire, gas leak, etc ) happened and detected, , alarm system
alarm right away.
In a ARM status, the panel [ ARM ] light is on.
To activate using remote control: press [ARM ] key once.
STAY ARM
2
This is for partial arming of the alarm system when there are people at home, only some of
the selected sensors are activated and could be triggered by events.
In a STAYARM status, the panel [ARM ] light is flashing.
To activate using remote control: press [STAY] key once.
DISARM
All sensors are deactivated and will not be respond to any events.
In a DISARM status, the panel [ ARM ] light is off
To activate using remote control: press [DISARM] key once.
EMERGENCY
When an emergency occurs, press emergency button on the remote or the * button on
panel to activate alarm.
2.2System Setup
2.2.1 Panel Setup
Alarm panel should be installed at a central location with best transmission to all the
wireless sensors and accessories. Keep the panel well away from large metal objects or
household appliances with high-frequency interference, and avoid barriers such as
concrete walls with metal frame inside and fire doors.
function
Indications
Description
Built-in speaker
short "beep" once
KeyTip
3
"beep", "beep" two short
tones
Exit configuration or learnt
succeed
"beep", "beep", "beep" three
short tones
Error indication
Voice prompt
The prompt voice of the
function and status
ARM LED
Light up
Alarm panel at ARM state
Rapid flashes
Alarm panel at STAY ARM
state
Flash slowly
Alarm panel at delay ARM or
recording state
Off
Alarm panel at DISARM state
Defense zone indicating
light(1~6)
Light up
A(1~6) zone alarm
One LED flashing
This zone enter delay alarm
state
All flashing
Unloaded SIM card or
loaded wrong
GSM Signal indicator
Flash one time for 1s
GSM Signal weak or
unloaded SIM card
Flash one time for 3s
GSM signals and SIM card
are normal
3 Installation of Panel
3.1 Alarm Panel Initial Setup
Load the SIM Card, connect telephone line, fix the GSM Antenna, connect the power and
other cables if any, then power up alarm panel. The alarm panel voice prompt "Welcome to
use alarm system", and start self-test the GSM network, “GSM Signal indicator ” flash one
time each 1s means it's searching the GSM signals ,when“GSM Signal indicator ” flash one
time each 3s means GSM signals and SIM card are normal.( it takes about 10 seconds or
so for searching).Remark : if all defence zone indicating light(6) is flashing and the alarm
panel restart for 20s means Unloaded SIM card or loaded wrong.
Upon everything working properly, the battery switch should be at the [ON] position for
continuous charging.
3.2 Pre-record Voice Message
Alarm panel will play a pre-recorded voice message after the alarm call when a pre-set
phone number upon alarm. To record customized message:
  Press and hold "SET"Key 3s to enter the configuration mode:
  Speak your message at the panel for recording
  System will record 10 Seconds and then automatically exit; or press any key to end
whenever your message end.
  Press"SET"Key to exit setup status.
3.3Enable or disable the GSM Module:
4
System default the GSM module is on . if the user not installed the SIM card , the host will
restart until find SIM card and GSM signal.
Remark: If set the GSM module to off, the alarm system only used as the live alarm
system,only cleared the police , can not dialed the phone alarm number.Moreover ,the host
without the SIM card would not restart when you closed the GSM module.
3.3.1 Close GSM module method:
●In the disarm status, press [SET] key for 3 seconds, release it when the recording light on .
● Wait 2seconds, and then hold the [SET] key 3 seconds once again, the panel will respond
with "di ,di,di" three times means changing into the state of closed the GSM module .
● Turn on the power supply again after power off . the panel will prompt "welcome to use
alarm system ", and "di di di" three times ,means the GSM module is off.
3.3.2 Open GSM module method:
●In the disarm status, press [SET] key for 3 seconds, release it when the recording light on .
● Wait 2seconds, and then hold the [SET] key 3 seconds once again, the panel will respond
with " di,di" twice means changing into the state of open the GSM module .
● Turn on the power supply again after power off . the panel will prompt "welcome to use
alarm system ", and "di" once ,means the GSM module is on.
Remark:If the GSM module is off,the alarm system would be can not read the SIM
card .
3.4 Add Remote Control:
  Press 【SET】key 1s ,all defence zone indicator light would be on and voice prompt"
add remote control " to enter the configuration mode:
  Then press any key of the remote control to send a signal to the alarm panel, voice
prompt " learning successful", beep only once means the remote control has been
configured before.
  Alarm panel can configure up to 50 remote control of different addressing. Upon
completion press 【SET】6 times every 1s to exit the configuration mode.
3.5 Delete the remote control:
  Press 【SET】key 1s , alarm panel beep once ,all defence zone indicator light would
be on and voice prompt" add remote control " to enter the configuration mode:
   nd then hold 【SET】key 3s ,alarm panel beep twice ,all defence zone indicator is
off ,means all remote control deleted.
3.6 Add detector
  Press 【SET】key 1s , alarm panel beep once ,all defence zone indicator light would
be on and voice prompt" add remote control " to enter the configuration mode:
   Press【SET】key 1s again ,the first defence zone indicator light on ,and voice
prompt " learning one zone " to enter the configuration mode.
  Then trigger the detector to send a signal to the alarm panel,voice prompt " learning
successful", beep only once means the detector has been configured before.
  Press【SET】1s again ,the second defence zone indicator light on ,and voice
prompt " learning second zone " to enter the configuration mode.And so on, for each of
the rest defence zones .
  Last press【SET】again ,alarm panel would be beep twice , and all indicator light
off to exit the configuration mode. Alarm panel can configure up to 50 sensors of different
5
addressing.
3.7 Delete detector
  Delete the sensor of first defence zone : press 【SET】twice ,and then press
【SET】3s when the first defence zone indicator light on ,the alarm panel beep
twice ,means delete the detector of first zone successfully.
  Delete the sensor of second defence zone : press 【SET】three times ,and then
press 【SET】3s when the second defence zone indicator light on ,the alarm panel
beep twice ,means delete the detector of second zone successfully.
  Delete the sensor of third defence zone : press 【SET】Four times ,and then
press【SET】3s when the third defence zone indicator light on ,the alarm panel beep
twice , means delete the detector of third zone successfully .
  Delete the sensor of fourth defence zone : press 【SET】five times ,and then
press【SET】3s when the fourth defence zone indicator light on ,the alarm panel beep
twice , means delete the detector of fourth zone successfully .
  Delete the sensorof fifth defence zone : press 【SET】six times ,and then press
【SET】3s when the fifth defence zone indicator light on ,the alarm panel beep twice ,
means delete the detector of fifth zone successfully .
  Delete the sensor of sixth defence zone : press 【SET】seven times ,and then press
【SET】3s when the sixth defence zone indicator light on ,the alarm panel beep twice ,
means delete the detector of sixth zone successfully . 4 Command Reference
This system supports two methods of configuration including telephone set and
SMS messaging. Following are examples how instructions are given via one of the
three methods of setting
Example: you want to change the first phone number for voice calling to 13899998888:
Method 1: By telephone set
Calling into the alarm panel, upon connected, alarm panel will ask for password, it is 1234
as the default, then press #, and then press 3113899998888# , press the * then press # to
exit configuration mode.
Method 2: Using SMS
On your mobile phone, compose a SMS message as 12343113899998888# and send to
your alarm panel.
4.1 Commands for Configuration
Set up voice alarm
phone number
To set the 1st group to the 6th group of voice alarm phone
number 【1-6 】indicates that the first group to the sixth group
alarm number correspondingly.
Example: If the user wants to set 13812345678 for the first set of
voice alarm phone number
Method one: Remote calling into the alarm panel put in password
(initial password: 1234 ) when being asked, then press the # key,
hear the voice prompt means the host into setting state.
In remote setting, press a digital then the host will broadcast one
digital speech, if press a digital not broadcast speech or press
once broadcast second speech mean setting not correct. Press*
key to exit.
Syntax:
【3 】+ 【1-6 】
+ 【Phone number】
+ 【# 】
6
Method two: Send SMS messages 12343113812345678# to a
alarm panel (which at the beginning of 1234 is the user
password), the alarm panel will reply with SMS message "Group
1 phone number :13812345678” to confirm the 1st group alarm
phone number is set to13812345678 successfully.
For users using the telephone line extension, you should dial the
number 13812345678+*+extension number.Here one * means
wait 1s,Two * means wait 2s .
Remark:If enable the dialing of power off function ,when power
off,it will automatically dial the preset telephone number ,and
voice prompt "zero zone alarm .
Delete voice alarm
phone number
Used to delete the first groups to the sixth group alert phone
numbers
Example: If you want to delete the first set of telephone alarm
number,
Method one: After entering the telephone remote setting status,
press 31#.
Method two: Send SMS message 123431# On the alarm panel,
alarm panel reply " Group 1 phone number: ” to confirm the 1st
group alarm phone number has been removed.
Syntax: 【3】+【1-6】
+【#】
Set phone number
to receive SMS
message
To set the first group to the third group of phone number for SMS
message. When alarm panel is alert, it sends a SMS message to
the three sets of numbers one by one.
Example: If the user wants to set 13812345678 SMS for the first
group of SMS message
Method one:
After calling and connected to the panel from remote, press
3713812345678#
Method two: Send SMS message 12343713812345678# to the
panel.
Remark:
When AC power off or on ,it will send SMS message to the preset
telephone number.
Syntax:
【3】+【7-9】+
【Phone number】+
【#】
Delete SMS phone
number
Used to delete the first group to SMS of the third group police
number
Example: If you want to delete the first set of SMS message
phone number,
Method one: After calling and connected to the panel from
remote, press 37#
Method two: Send SMS message 123437# to the panel
Syntax:
【3】+【7-9】+【#】
Password
modification
Used to modify the user password, the default user password is
1234
Example: If you want to set up a new user password 4321
Method one: After calling and connected to the panel from
Syntax:
【50】+ 【4 digits
7
new password】+
【#】
remote, press 504321#
Method two: Send SMS message 1234504321#
Set delay for system
arm
Upon armed from the remote control or alarm panel, the alarm
panel is set to delay 0 -99 before at the ready status of ARM.
The system default is 00 seconds.
Example: users need to set the delay time for 60 Seconds.
Method one: After calling and connected to the panel from
remote, press 5160#
Method two: Send SMS messages12345160#
Syntax:
【51】+【00-99
Second 】+ 【# 】
Set the time of delay
for alarming
Set the time of delay upon alram, it can be set to 0-99 seconds,
the system default is 00 seconds.
Example: the user needs to set the alarm delay time to 60
Seconds.
Method one: After calling and connected to the panel from
remote, press 5260#.
Method two: Send SMS message 12345260#
Syntax:
【52】+ 【00-99
Second】+ 【#】
Set length of Siren
sound
Set alarm length of sounding when panel alarm, could be set to
0-20 minutes, factory default is 1 minute.
Example: you want to make a siren sound 5 Minutes.
Method one: After calling and connected to the panel from
remote, press 5305#.
Method two:Send SMS messages12345305#
Syntax:
【53】+ 【00-20
Minutes】+ 【# 】
Alarm linkage
function on or off
Enable or disable the alarm linkage function. 1 is enabled and 0 is
disabled, the system default is 1.Example: users need to set the
alarm linkage function off,
Method one:After calling and connected to the panel from remote,
press540#
Method two:Send SMS message 1234540#
Method three: 1234200#
Remark:If enable the alarm linkage function,when
alarming,the relay absorption would change the circuit condition
between NO and COM . The time of relay actuation is the same
with siren sound time. When disable the alarm linkage
function ,the relay of the panel can remote control the home
appliance.After calling and connected to the panel from
remote,input the password,press 9 ,the relay on,0 OFF. Or send
SMS 12343#ON,12344# Means OFF。Can control the power
which below 1000W ,such as electric cooker ,lamp,water suction
pumpetc.
Syntax:
【54】+【0/1】+
【#】
Set audible
confirmation for
remote control
operation
1 means on and 0 means closed, the default is on.
Example: set panel without sound when remote control is sending
signal.
Method one: After calling and connected to the panel from
8
Syntax:
【55】+【0/1 】+
【# 】
remote, press 550#
Method two:Send SMS messages 1234550#
Set date and time
settings
Set the system date and time
Example: it is now 1st of July of 2012 9 :00 :00 am
Method one: After calling and connected to the panel from
remote, press 56120901090000#.
Method two: Send SMS message123456120901090000#
Syntax:
【56】+ 【2-digits
year】+【01-12 The
Month】+ 【01-31
Day 】+ 【00-23
Hour】+ 【00-59
Minute】+ 【00-59
Second " + 【# 】
The first set of
Scheduled arm and
disarm time setting
To set the time for scheduled arm and disarm,
Example: set up the first group scheduled time to arm at 22 :
00 pm and disarm at 07 :00 am, this is valid for Monday,
Tuesday, Wednesday, Thursday and Friday of each week.
Method one: After calling and connected to the panel from
remote, press 572200070012345#
Method two: Send SMS message 1234572200070012345#
Remark:set the arm time and disarm time to be 24:00,would be
closed the scheduled arm/disarm function .
Syntax:
【57 】+ 【AAAA
Scheduled time of
arm 】+ 【BBBB
Scheduled disarmed
time 】+【Number
of week 】+
【# 】
The second set of
Scheduled arm and
disarm time setting
To set the time for scheduled arm and disarm,
Example: set up the second group scheduled time to arm at
12 :00 pm and disarm at 13 :00 am, this is valid for Monday,
Tuesday, Wednesday, Thursday ,Friday,Saturday and Sunday of
each week.
Method one: After calling and connected to the panel from
remote, press 58120013001234567#
Method two: Send SMS message 123458120013001234567#
Remark:set the arm time and disarm time to be 24:00,would be
closed the scheduled arm/disarm function .
Syntax:
【58 】+ 【AAAA
Scheduled time of
arm 】+ 【BBBB
Scheduled disarmed
time 】+【Number
of week 】+
【# 】
Set the type of
defense zone
To set 6 wireless zones type, 01~06 represents 1-6zone number,
1-5 represents one of the 5 zone type:
1. NORMAL
2. STAYARM
3. INTELLIGENT
4. EMERGENCY
5. CLOSED
The last 0/1 represents 0 siren of panel produce no sound upon
alarming while 1 is sounded.
Syntax:
【60】+ 【01-06
zone number 】+
【1-5 Type 】+
【0/1 】+ 【# 】
9
Example: Set zone number 2 as STAY zone type, and siren not
sound upon alarming
Method one: After calling and connected to the panel from
remote, press 600220#
Method two: Send SMS message 1234600220#
Set mode of wired
alarm zone
Set wired alarm zone to NO or NC. The zone number of 07-10
are wired defense zones, system default is 07-10 are wired zones
with NO mode.
1-5 represents one of the 5 zone type:
1.NORMAL
2.STAYARM
3.INTELLIGENT
4.EMERGENCY
5.CLOSED
The first 0/1 represents 0 siren of panel produce no sound upon
alarming while 1 is sounded.
The second 0/1 ,0 means NO and 1 means NC
NO means short-circuit to alarm
NC means open-circuit to alarm
Example: Set 7 zone to NORMAL, NC alarm, without sound when
alarming ,
Method one: After calling and connected to the panel from
remote, press6107101#
Method two: Send SMS message 12346107101#
Remark:
1) set 7 zone to NO alarm ,in the arm status ,when7 and GND to
be short-circuit condition ,the alarm system would be alarming.
2) set 7 zone to NC alarm ,in the arm status ,when 7 and GND to
be open circuit condition ,the alarm system would be alarming.
Usually Suitable for connect the alarm port of the wired
accessories.
Syntax:
【61】+【07-10,zone
number】+【1-5】+
【0/1】+【0/1】+【#】
Siren volume
adjustment
Valid value is from 00 to 99 as largest, system default is the
largest.
Example: users need to set volume to 50 。
Method one: After calling and connected to the panel from
remote, press 6250#
Method two:Send SMS message 12346250#
Syntax:
【62】+【00-99】+
【#】
Auto dial-up function
when power off
When power off ,auto dial function on or off .1 for on ,0 for off ,the
panel would not dial the pre-set phone number.Default is 0.
Example: user want to receive the call from the panel when power
off .
Method one: After calling and connected to the panel from
remote, press 641#
Method two:Send SMS message1234641#
Syntax:
【64】+【0/1】+【#】
10
Set audible
confirmation from
panel to on or off
Alarm panel will produce audible confirmation beep upon receipt
of signal from remote control. 1 is on, 0 is off, default is on.
Example: users need to disable the audible confirmation.
Method one:After calling and connected to the panel from remote,
press110#
Method two:Send SMS message 1234110#
Syntax:
【11】+【0/1】+【#】
Enable or disable
the SMS Messaging
1 is on and 0 is off. Default is on
Example: the user will need to turn off the text messaging feature
Method one: After calling and connected to the panel from
remote, press120#
Method two:Send SMS message 1234120#
Syntax:
【12】+【0/1】+【#】
Restore factory
setting
System restore factory setting
Method one:After calling and connected to the panel from remote,
press130000#
Method two: Send SMS message1234130000#
Remark:This feature will restore all settings to factory default
apart from the configuration of sensors and remote control.
Syntax:
【13】+【0000】+【#】
Total System Reset
Disconnect power to the alarm panel, turned off the battery
switch alarm panel, then press and hold the alarm panel of SET
button while power-on. The system will respond with long “beep”
for 5 seconds, then can release SET button. The system is now
totally reset. All configuration has been cleared, all sensors and
remote controlled are deleted and password is restored to original
1234.
Syntax:
Press and hold the
SETand power on.
Note: Other than the SMS commands for assigning specific phone number for certain zone,
alarm panel will respond to all other SMS commands by replying confirmation of setting by
SMS.
4.2 Commands of System Enquiries
The following instructions are only for SMS command to control panel remotely:
Remote SMS disarm
Send SMS message 12340# into alarm panel
Note: 1234 is the password
0#
Remote SMS
NORMAL arm
Send SMS messages 12341# to set the alarm panel toARM
1#
Remote SMS STAY
arm
Send SMS message 12342# to set alarm panel to STAYARM.
2#
Remote SMS turn on
relay 3#
Send SMS message 12343# to turn on the relay of the alarm
panel
Remote SMS turn off
relay 4#
Send SMS messages 12344# to turn off the relay of the alarm
panel
Query the AC power
Send SMS messages 12346# to the alarm panel, the alarm
11
status 6#
panel replies AC power ON or AC power OFF.
Query the alarm panel
general settings
Query the alarm panel status included: arm/disarm, relay status,
status of integrated alarm, status of SMS messaging,
status of remote operation, password, delay alarming setting,
delay arm setting, length of time of siren sounding, volume of
siren, keyboard locking status, audible confirmation
Example: Send SMS message 123420# to the alarm panel, the
alarm panel replies with a list of related setting:
Arming → armstatus
Relay out off → relay offVoice on → voice on
Dial on → Auto dial the preset phone alarm number when
power off .
Alarm out on →alarm linkage on
Send SMS on→SMS messaging on
Remote set on→Siren sound when remote control operation
Password:1234→the password is 1234
Alarm delay:00s→delay alarming 0 second
Arm delay:00s→ delay arm 0 second
Siren on 1 min→ siren sounding time 1 minute
Siren VOL:99→ volume of siren 99
20+【#】
Query voice alarm
phone number
Return a list of 1st to 6th phone number group for voice alarm
and 1st to 3rd SMS alarm number .1-6 for 1st to 6th phone alarm
number ,7-9 for 1st to 3rd SMS alarm number
Example: Send 123421# to the alarm panel, the alarm panel
replies " 1 : 13712345678” means the first voice alarm phone
number is 13712345678
Remark: phone alarm number can be the same as SMS alarm
number .
21+【#】
Query the system time
and scheduled
arm/disarm time
Query the system time
Example: Send 123422# to the alarm panel, the alarm panel
replies “System clock :2012-07-01 12:00”. Means the system is
now 1st of July of 2011 12 :00 :00 am.
AMR 1:22:00
DISARM 1:07:00 12345 ARM 2:24:00 DISARM 2:24:00
1234567
Means: the first group scheduled time to arm at 22 :00
pm and disarm at 07:00 am, this is valid for Monday,
Tuesday, Wednesday, Thursday and Friday of each week.
The second scheduled arm/disarm time function is disabled
22+【#】
Query the type and
siren setting of all
defence zones
Query the type and siren setting of all defense zone
Example: Send 123423# to the alarm panel,
Reply message format and analytic:
12
23+【#】
1:Normal On means the first zone is normal zone,siren on.
2:Stay Off means the second zone for STAY alarm, siren off
3: Smart On means the third zone for INTELLIGENT,siren on
4: Urgent On means the fourth zone for EMERGENCY,siren on
5: Off On means the fifth zone for CLOSE, in close state
6: Normal On means the sisth zone for NORMAL,siren on
7: Normal On NO means the seventh zone is NORMAL,siren
on,and short-circuit to alarm
8:Normal On NC means the eighth zone is NORMAL, siren
on,and open-circuit to alarm.
9:Normal on NO means the ninth zone is NORMAL,siren on,
And short-circuit to alarm
10: Normal siren NO means the tenth zone is NORMAL,siren
will alarm ,and short-circuit to alarm
Query the customized
SMS message content
Query zone 00-99 the content of SMS message customized.
Example: Send 123480# to the alarm panel to query for zone 01
message content.
Reply message format and analytic:
1:The first zone message content"1 zone alarm "
2:The second zone message content"2 zone alarm "
3:ditto
10:ditto
80 +【#】
Customize the SMS
message for certain
zone
Used to customize the SMS message for zone 1-9.(this content
is sent into the first to the third SMS message numbers users
reset after this zone alarming,content confined within 12 Letters)
Example: Send message “123481 Front Door Alarm#” to the
alarm panel will set alarm panel to send SMS message “Front
Door Alarm” upon zone 1st alarm being triggered
Reply message format and analytic:
1:the first door open means the first zone message content to
"1 door open"
2:2 zone means the second zone message content"2 zone
alarm"
3: 3 zone means the third zone message content"3 zone
alarm"
4: ditto
10:0 zone means the tenth zone message content "10 zone
alarm "
8+【1-9zone number】
+【message content】
+【#】
Customize the SMS
message for 10th
zone
Set the tenth zone message content
Example:change the tenth zone message to "1 win open" send
a message "123490 1 win open" to the panel.
90+ 【message
content】+【#】
Note: "1234" string shown above table all represents the password. User can change
13
password and thus should adjust the commands listed accordingly.
5 Remote Control of Panel
5.1 After receiving the Panel Alert:
After Panel alerts, it will automatically dial the preset telephone number for three times until
connected ,and send SMS message to the preset telephone number . When the user picks
up the phone, a piece of pre-recorded voice message will be played back immediately and
let the receiver noted about the event. Upon receiving the call, it can also control the alarm
panel remotely via the phone (according to the command below). User will not be asked for
password upon connected and alarm will automatically hang up call within receiving any
instruction within 20 seconds.
[1] key: arming [2] key: disarming
[3] key: monitoring open [4] key: monitoring closed
[5] key: turn on announcement [6] key: turn off announcement
[7] key: siren ringing [8] key: stop siren sound
[9] key: turn on relay [0] key: turn off relay
[*] key: hang up, system will not dial the next number on list.
Remark:
-If not hang up using [*] key or disarm using [2] key, the system will retry to call the next
phone numbers on list until one connected.
-Panel will not ask for password when dialing out upon alarming.
Remark: monitoring time is 20 seconds. If continue to monitor, user needs to press 3 key
again. Press [3]+[5] To support talkback function, the host needs to connect to another
passive loudspeaker, which are 8 ohm and its power above 0.5 W.
5.2 Remote Dialing In Operation:
Remote-control operations can be done via any phone. You can just dial into the alarm
panel and user will be asked for password upon connected and alarm will automatically
hang up call within receiving any instruction within 20 seconds or password is incorrect.
(original password 1234)
[1] key: arming [2] key: disarming
[3] key: monitoring open [4] key: monitoring closed
[5] key: turn on announcement [6] key: turn off announcement
[7] key: siren ringing [8] key: stop siren sound
[9] key: turn on relay [0] key: turn off relay
[*] key: hang up,
[#] key: Enter the system remote configuration mode, Without receiving no instruction, the
panel will automatically hang up after 20 seconds.
6 Types of Alarm Zone
6.1 Definitions of Zones
The alarm supports 10 distinguishable defense zones and they can be classified into one of
the5 Zone Types with their respective characteristics.
Type
ID
Zone Type
Interpretation
1
NORMAL Defense
Zone
the Panel only works on the arming status. When
disarming, there is no response.
14
2
STAY Defense zone
(AT-HOME Defense
zone)
can be shut off solely through the remote control
(keyboard) to avoid the Infrared Detectors and other
in-room detectors from misinformation when master is
resting at home.
3
INTELLIGENT
Defense zone:
if the detector in the Defense zone is triggered only once,
it will not immediately alarm. But if being triggered once
again within 30 seconds after the first triggering, it will
alarm immediately.
4
EMERGENCY
Defense zone:
no matter on arming or disarming status, if detector is
triggered it will alert. Usually used in connecting with
Smoke Detectors, Gas Detectors and emergency button,
etc.
5
CLOSED Defense
zone:
no matter arming or disarming status, detectors will not
alert even being triggered.
.2 Default
Operation
password
1234
Siren volume
99
Alarm linkage
Enable
1-10zone type
Normal
GSM moudle
Enable
Siren sound
1minute
Audible confirmation for remote operation
Enable
DelayARM
0s
Delay alarming
0s
7-10wired zone
alarm type
NO
1-10zone alarm
Siren sound
SMS message
Enable
1-10Zone SMS message content
6.3 Fitting parameters:
-Input voltage: DC9V-12V
-Standby currents: < 25 mA
-Alarm current: <450 mA
Wireless frequency: 315/433/MHZ ,2262/1.5-4.7M ,EV1527/300K
-GSM Format: Support GSM850/900/1800/1900MHz (option)
Backup battery: DC7.4V
Alarm loudness: 110dB
-Detailed parameters: The alarm should be compatible with PT2262, PT2240 and
EV1527. Using PT2262 encoding, the resistance is recommended 1.5M-4.7M; using
with EV1527 encoding, the resistance by 300K, data recommended 1010.
-
APP Operation Manual
First you need to search the software in google play or IOS market with the name of "gsm
alarm" and download the one with image of , or scan the QR code on the package
box to download the software.
1.Add device
1). add the device,press “Device”(at the bottom of the page),
2)device name you can make a name yourself, just like “home”, “office” or any others.
(since you might have two alarm systems need to be controlled with one smart phone. One
15
alarm in home and the other one in office)
P.S.: One APP supports more than one alarm system
3). Device number is the phone number of the sim card which you already put inside the
alarm system.
4). Device password is the password of alarm system, the factory setting is 1234
2.Operate
Back to the first home page,choose the device you added just now,then you can operate it.
Pictures in next page↓↓↓↓↓
-

Other ChinaPST Security System manuals

ChinaPST PST-G10A User manual

ChinaPST

ChinaPST PST-G10A User manual

ChinaPST PST-G66W User manual

ChinaPST

ChinaPST PST-G66W User manual

ChinaPST PST-OFS04 User manual

ChinaPST

ChinaPST PST-OFS04 User manual

ChinaPST PSTN User manual

ChinaPST

ChinaPST PSTN User manual

Popular Security System manuals by other brands

Sting HD-104 user manual

Sting

Sting HD-104 user manual

Lukas LK-790 user guide

Lukas

Lukas LK-790 user guide

Lorex Vantage Edge+ CVC6996 Brochure & specs

Lorex

Lorex Vantage Edge+ CVC6996 Brochure & specs

miGuard SPS260 instructions

miGuard

miGuard SPS260 instructions

ADEMCO 4110DL user manual

ADEMCO

ADEMCO 4110DL user manual

GE Telligence Patient-Staff Communications... Operation manual

GE

GE Telligence Patient-Staff Communications... Operation manual

Cavius CV4002 installation guide

Cavius

Cavius CV4002 installation guide

Fishguard Fx System user manual

Fishguard

Fishguard Fx System user manual

Honeywell ADEMCO 5809 Installation and setup guide

Honeywell

Honeywell ADEMCO 5809 Installation and setup guide

JSG M2AP01 Operation & installation manual

JSG

JSG M2AP01 Operation & installation manual

FältCom ECII SE Manual and installation instructions

FältCom

FältCom ECII SE Manual and installation instructions

E2S BExBG05D-P-SIL instruction manual

E2S

E2S BExBG05D-P-SIL instruction manual

ABB FIM 1300 Series installation instructions

ABB

ABB FIM 1300 Series installation instructions

Prestige APS510Z Quick installation guide

Prestige

Prestige APS510Z Quick installation guide

Rutenbeck TCR easy Plus Alarm operating instructions

Rutenbeck

Rutenbeck TCR easy Plus Alarm operating instructions

Bosch LTC 8016/90 instruction manual

Bosch

Bosch LTC 8016/90 instruction manual

IMAGE 4SECURITY Guardsman installation instructions

IMAGE 4SECURITY

IMAGE 4SECURITY Guardsman installation instructions

ZK Technology iClock 2500 manual

ZK Technology

ZK Technology iClock 2500 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.