1
Proximity Intermediate Control

MF1368A8
Effective June 1996
CAUTION
The equipment may start automatically.
Disconnect electrical power prior to
servicing the equipment.
Keep hands and tools clear of
the auger at all times.
Part No. 36880
Introduction
The Proximity Intermediate Control w/On Delay was designed for brood applications.
The Proximity Intermediate Control uses a Proximity Switch to sense feed and cause
the system to start and stop. The Proximity Switch has sensitivity adjustment and de-
lay adjustment screws.
The Proximity Intermediate Control is to be located just prior to the brood partition.
Do not hinder bird movement around the Intermediate Control. Provide adequate light-
ing so that the birds will not shy away from the Intermediate Control.
2
Figure 1. Enlarging the Outlet Holes (front view).
Installation
The Auger Tube with the Intermediate Control must have each hole enlarged, as
shown in Figure 1. This will ensure total feed dropout before the Intermediate Control.
Use a hacksaw and tin snips to enlarge hole size. Be sure there are no burrs inside
the tube to catch the auger.
Install the Proximity Intermediate Control:
Remove the (2) Hex Head Screws securing the Tube Retainer on the Inter-
mediate Control. See Figure 2.
Lift off the Tube Retainer.
Cradle the Feeder Tube in the Control Housing. The Feeder Tube may have
to be turned to allow the pan to hang straight.
Clamp the Control in place by inserting tabs on the Tube Retainer into the
slots on the Control Body. Install and tighten the two hex head screws, re-
moved above.
Figure 3 shows an Intermediate Control installed in the appropriate location.
Key Description
1(2) Hex Head Screws
2Tube Retainer
Key Description
1Auger Tube
2Tube Seam
3Cut here to enlarge outlet holes.
Figure 2. Intermediate Control Installation (side view).
3
Key Description
Hopper at the end of the Feeder Line.
2
3Intermediate Control Unit
Partition or Curtain
Wire the Control
the circuit breakers before performing any service work.
Important: constant
the black and the white wires.
4
Proximity Switch Schematic
Important:
This wiring schematic represents the switch in the non-powered condition. When power is
applied the N.O. and N.C. contacts reverse.
Refer to the wiring diagrams, above, when wiring the Proximity Switch.
Proximity Intermediate Control Internal Wiring
5
Operation
When the switch senses feed, the internal relay is activated immediately, stopping the
system. When feed is removed, the delay is activated and prevents the system from
starting until it has timed out.
Setting the Delay
The Proximity Switch includes an adjustable delay. The delay may be set from 1 sec-
ond to 10 minutes.
A. Use a small screw driver provided to turn the Delay Adjustment Screw (see
Figure 4). Turn the screw counter clockwise until the light stays on. Turn the
screw clockwise one complete revolution. This sets the delay to 1 second.
B. To increase the delay, turn the Delay Adjustment Screw clockwise.
Watch the indicator light; quick flashes = shorter time delay, slow flashes =
longer time delay.
Adjusting the Sensitivity
The Proximity Switch is shipped with the sensitivity preset at the factory. This setting
is adequate for most feed types and conditions. However if the sensitivity does need
to be adjusted, carefully follow these instructions:
A. Allow power to be supplied to the switch for at least 15 minutes to properly
warm the sensor. See the wiring diagrams in this manual.
B. Set the Proximity Switch time delay to 1 second as specified above.
C. Use a small screw driver to remove the caulk concealing the Sensitivity
Adjustment Screw.
D. Greater switch sensitivity is achieved by turning the Sensitivity Adjustment
Screw clockwise.
Less switch sensitivity is achieved by turning the Sensitivity Adjustment
Screw counterclockwise.
Note the screw orientation before beginning adjustment. Adjust the Sensitiv-
ity Adjustment Screw 1/4 turn, test switch, continue adjusting as required.
Figure 4. Proximity Switch Adjustments (end view of Proximity Switch).
6
Item Description Part No.
1Feeder Pan 25281
2Switch Mount Collar 36966
3Grill 25280
4Support Cone 36866
5Tube Support 14754
6Tube Retainer 14756
7Back Cover 36869
8Front Panel 37061
9Switch Box Cover 27047
10 Gasket 6777
11 Switch Box Cover 6776
12 Danger Decal 2529-480
13 Switch Box 36334-1
14 Proximity Switch Ass’y 36881-1
Proximity Switch 34255
Safety Cap 36467
Liquid Tight Conn. 23779
15 Control Unit Sleeve 29349
16 Cord Assembly 4999-96
17 Liquid Tight Connector 24685
18 DPST 240 V. Relay 34654
19 Danger Decal 2527-9
Proximity Intermediate Control w/On Delay
Part No. 36880
7
This page intentionally left blank.
8
Contact your nearby Chore-Time distributor or representative for additional parts and information.
Chore-Time Equipment, A Division of CTB, Inc.
P.O. Box 2000, Milford, Indiana 46542-2000 U.S.A.
Phone: 219-658-4101
Printed in the U.S.A.
Made to work.
Built to last.

Other Chore-Time Controllers manuals

Chore-Time SUPER-Selector PT 40866 User manual

Chore-Time

Chore-Time SUPER-Selector PT 40866 User manual

Chore-Time 28999 User manual

Chore-Time

Chore-Time 28999 User manual

Chore-Time Feeder Control Instruction Manual

Chore-Time

Chore-Time Feeder Control Instruction Manual

Chore-Time 52410-6 User manual

Chore-Time

Chore-Time 52410-6 User manual

Popular Controllers manuals by other brands

digitalview ALR-1920-SDI instructions

digitalview

digitalview ALR-1920-SDI instructions

Sensor Therm Regulus RD user manual

Sensor Therm

Sensor Therm Regulus RD user manual

HQ Power VDPLTC manual

HQ Power

HQ Power VDPLTC manual

OutBack Power FLEXmax Extreme quick start guide

OutBack Power

OutBack Power FLEXmax Extreme quick start guide

HANYOUNG NUX MT100 user manual

HANYOUNG NUX

HANYOUNG NUX MT100 user manual

red lion CSMSTR manual

red lion

red lion CSMSTR manual

FRO­NIUS RCU 2000 operating instructions

FRO­NIUS

FRO­NIUS RCU 2000 operating instructions

Channel Plus MDS-6A Installation manual and user's guide

Channel Plus

Channel Plus MDS-6A Installation manual and user's guide

Planet NMS-500 Quick installation guide

Planet

Planet NMS-500 Quick installation guide

NovaStar MX40 Pro user manual

NovaStar

NovaStar MX40 Pro user manual

Ebmpapst CGCXX00000 Operating and maintenance instructions

Ebmpapst

Ebmpapst CGCXX00000 Operating and maintenance instructions

Onq lyriQ 15-0391 Instruction/installation sheet

Onq

Onq lyriQ 15-0391 Instruction/installation sheet

Promise FastTrak S150 TX2plus quick start guide

Promise

Promise FastTrak S150 TX2plus quick start guide

Samwontech TEMI1000 Series Operation manual

Samwontech

Samwontech TEMI1000 Series Operation manual

MICROMATIC Rotac SB-18-1V OVERHAUL INSTRUCTIONS

MICROMATIC

MICROMATIC Rotac SB-18-1V OVERHAUL INSTRUCTIONS

KEBCO COMBIVERT F6 Instructions for use

KEBCO

KEBCO COMBIVERT F6 Instructions for use

CS-Lab CSMO IP-M user guide

CS-Lab

CS-Lab CSMO IP-M user guide

Pegasus Astro Dual Motor Focus Controller v3.x manual

Pegasus Astro

Pegasus Astro Dual Motor Focus Controller v3.x manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.