Cielsa Dawn E021 User manual

INSTALLATION
AND USER GUIDE
APPLICABLE MODEL:E021
Installtion for electronic door lock
Please read this manual before installing.

TABLE OF CONTENT
CHECK AND PREPARATION
INSTALLTION STEPS
INSTRUCTION OPERATION
SAFETY PRECAUTIONS

WELCOME
Required tools
This guide will walk you through step-by-step how to
install and get your product up and running.
Installation generally takes less than 30 minutes.
If you have any questions, please feel free to contact
us.

Check and preparation
Check dimensions
remove existing deadbolt or use provided template to bore new holes
Before getting started, ensure the package contains the following components
CHECK AND PREPARATION INSTALLTION STEPS INSTRUCTION OPERATION

How to bore new holes?
Put the template on the door panel as shown in the
drawing.
use the Template as an indication to mark the centre of
the circle on the door face and the centre of the door
edge.
Use the marks as a guide to drill holes
Drill the striker plate & strike box hole
a. Close the door, mark the top and bottom ends of the lock edges on the door frame, and draw a
centerline.
b. mark and drill a 1’’x4/5’’ (27x20mm) hole for striking plate box, with depth of 1’’(25.4mm).
c. Mark and drill a 2-6/24’’x1’’(58x25.4mm) hole for striking plate.
d. Fix striking plate box and striking plate with 2pcs 3/4’’ (19mm) screw.
CHECK AND PREPARATION INSTALLTION STEPS INSTRUCTION OPERATION

Installation Steps
ADJUST DEADBOLT AND INSTALL
1
Insert the deadbolt into mortise.Secure with
2 screws.
CHECK AND PREPARATION INSTALLTION STEPS INSTRUCTION OPERATION

Possi doluptam et parchitatur rempore,
volum versper eprovitatiae exerchi llander-
it vid quis cus eostin pra vel essitibusdam
qui vellupturi omniae venihit lab.
2INSTALL THE KEYPAD
Install front panel and front panel silicon pad,
make sure the latch bolt be contracte.
3FIXING OF REAR PANEL
Pass the IC wire and the latch link bar to
mounting plate.
Use the screws as shown in the gure con-
nect rear panel xing plate with latch and
door.
Note: Please place the IC line as shown in
the gure to avoid the lock latch out of con-
trol.
CHECK AND PREPARATION INSTALLTION STEPS INSTRUCTION OPERATION

INDENTIFY DOOR HANDING
4
The door is “Left-handle” if the hinges are on the
left side of the door.
The door is “Right-handle” if the hinges are on
the right side of the door.
Turn the piece as shown
Rotate the thumb turn piece as shown
CHECK AND PREPARATION INSTALLTION STEPS INSTRUCTION OPERATION

Rotate the thumb turn piece as shown
Install the rear panel.
Use the screws as shown connect rear panel
with latch and rear panel fixing plate.
INSTALL REAR PANEL:
5
Docking of the connector.
Pay attention to the direction of the inserted
connector.
• Turning the knob control the deadbolt.
• Hold down the back lock switch for 3s until a
“beep” sound is heard, thus enabling the anti-lock
state.In this case,only admin code can unlock in
the outside.Inside, turn the knob to release the
anti-lock and 2 beeps sound.
CHECK AND PREPARATION INSTALLTION STEPS INSTRUCTION OPERATION

When you complete the installation, follow this step to set the lock:
Ⅰ
SYSTEM SIGNALS
Instruction operation
use cases Sound Light
Correct user code entered to unlock 3 short beeps Blue ashes
Successfully locked 3 short beeps Blue ashes
Incorrect user code entered 4 short beeps white ashing
Successful programming 2 short beeps None
Unsuccessful programming 4 short beeps white ashing
Verication is correct or programming ends
successfully
1 long beeps None
Low battery alarm 4 short beeps None
Factory mode restored successfully 5 short beeps with
1 long beeps
white ashing with
green ashes
5 incorrect user codes entered 4 long beeps None
Registration ngerprint Every press of ngerprint 2 short beeps
Registration successful 1long beep
Registration failed 4 short beeps
Registration process blue ashes
Registration successful green ashes
Registration failed red ashes
Correct ngerprint unlock 3 short beeps green ashes
Incorrect ngerprint unlock 4 short beeps red ashes
TEST SYSTEM RESETTING ADD ADMIN CODE ADD GENERAL
USER’S CODES
CHECK AND PREPARATION INSTALLTION STEPS INSTRUCTION OPERATION

Ⅱ
TEST
You have complet ed the installation.Before setting up, you can use the follow methods to
test whether the installation successfully or not.
2. The keypad function: Press the lock key for a long time to lock;The factory status code is
“123456 “, press “123456” and “ ” to unlock.
3. The ngerprint function: Any ngerprint in the factory status can be unlocked
1. The key function: Insert the key into the key hole directly to test.
press the key press "123456"
NOTE:
the factory
status code is
“123456”
press the key
A B C
Any ngerprint unlcok,green ashes
CHECK AND PREPARATION INSTALLTION STEPS INSTRUCTION OPERATION

SYSTEM RESETTING
a.Removing one of the
Battery
b.Touch anywhere on
the keyboard
C. Install the battery back.
When the “1” of the key-
board ashes,long press
the Anti-Lock Switch for
10 seconds.
You will hear two beeps and a fast ashing blue light, and then a long beep means that
the lock is restored to the factory settings.
Ⅲ
• Indicator and sound of operation success/failure
a.The indicator will turn green and a long beep sound will be heard in the case of any successful
operation or normal operation.
b.The indicator will turn red and 4 short beep sounds will be heard in the case of any operational
failure or mis-operation
• The password consists of 6-12 bits
• Low Power
When the lock voltage is too low and the password is entered, the lock will emit 4 “beep” sounds
as an alarm prompt. You need to replace the battery in a timely manner.
If the voltage is too low ,the moving speed of the latch will be slow and the latch cannot be re-
tracted completely ,please replace the battery in time.
• Wrong code
If you enter incorrect passwords consecutively for more than four times, the keypad will be
locked for 1 min, and the system will make no response within 1 min and automatically unlock after
1 min.
Precautions
CHECK AND PREPARATION INSTALLTION STEPS INSTRUCTION OPERATION

Ⅳ
USER SETTING
A. ADD ADMINISTRATOR CODE
(ONLY ONE ADMINISTRATOR CAN BE ADDED. THE ID NUMBER OF THE ADMINISTRATOR IS 000.
THE SAME PASSWORD CANNOT BE REGISTERED REPEATEDLY.)
Move swiftly during programming. If no digit is pressed for 10 seconds,
the system will time out and you will need to restart the procedure.
Press
” 1 “
Enter
”123456”
Press
“ ”
Enter new
admin code
Enter new admin
code again
Press admin nger four times
Press
“ ”
Press
“ ”
eg, if you choose “ 666666” as the new admin code,the enter steps are as follows:
1 123456 666666 666666
• In the Default mode, press “ ”and enter “ 123456 ”, enter a new code(-
consisting of 6-12 bits),press “ ”, enter the new code again, press
“ ”, until a long beep sound is heard. The rst code is the admin code.
1
• In the Default mode, press “ ”and enter “ 123456 ”, press admin nger four
times 1
(6-12bit)
(original admin code)
eg, if you choose ngerprint as the new admin code,the enter steps are as follows:
1 123456 press nger four times
(original admin code)
Note:The admin code can only be one of the digital password and ngerprint.
CHECK AND PREPARATION INSTALLTION STEPS INSTRUCTION OPERATION

1 666666 333333 333333
eg, if “ 666666”or ngerprint is your admin code and you choose”333333”as the new user’s
code.
After add new password successfully, you can press “ ” “ 333333 ” “ ” to open the lock.
B. ADD GENERAL USER’S CODES
(CAN BE ADDED CONTINUOUSLY)
Press
” 1 “
Enter admin code Press
“ ”
Enter new
user passwprd
Enter new user
password again
Press user nger four times
Press
“ ”
Press
“ ”
• Press “ ”and enter admin password or ngerprint ,press ” ”, enter a user code(-
consisting of 6-12 bits),press “ ”, enter the user code again, press “ ”, until a long beep
sound is heard.
1
(6-12bit)
• Press “ ”and enter admin ngerprint, ,press user nger four times 1
eg, if “ 666666”or ngerprint is your admin code and you choose user ngerprint as the new
user’s code.
1 press user nger for times
After add new ngerprint successfully,you can press the nger on the ngerprint reader to
open the lock.
Enter admin ngerprint
1 admin ngerprint 333333 333333
666666
1 admin ngerprint press user nger for times
CHECK AND PREPARATION INSTALLTION STEPS INSTRUCTION OPERATION

• Press “ ” , enter the old admin code and press “ ”enter the old admin code and press
“ ”. Enter a new admin code and press“ ”. Enter the new admin code again and press “ ”.
Thus, the admin code is changed successfully.
2
C. CHANGE ADMIN CODE
Press
” 2 “
Enter
admin code
Press
“ ”
Enter old
admin code
Enter new
admin code
Press
“ ”
Press
“ ”
Enter new
admin code
again
Press
“ ”
(6-12bit)
eg, if you want to change the old admin code “666666” into the new one“555555”,the
enter steps are as follows:
2 666666 666666 555555 555555
eg, if you want to change the old admin password “666666” into the ngerprint,the enter
steps are as follows:
2 666666 666666 press nger four times
eg, if you want to change the old admin ngerprint into the new code”666666”,the enter
steps are as follows:
2 press admin ngerprint
press nger four times
Enter old admin ngerprint
666666 666666
• Password anti peeping function: you can add some irrelevant codes before and after the password,
and then press conrm (the maximum length is 15 digits). you can enter the password as follows:
XXX password XXX
CHECK AND PREPARATION INSTALLTION STEPS INSTRUCTION OPERATION

D. CHANGE GENERAL USER’S CODE
Press
” 2 “
Enter
admin code
Press
“ ”
Enter old
user code
Enter new
user code
Press
“ ”
Press
“ ”
Enter new
user code
aga in
Press
“ ”
(6-12bit)
eg, if your admin code is “555555” or ngerprint and you want to change the old user
code”333333 ”which ID is 002 into the new one“111111”.After the change,the ID of the new
user’s code“111111” still is 002 ,the enter steps are as follows:
2 555555 333333 111111 111111
eg, if your admin code is “555555“ or ngerprint and you want to change the old user
code”333333 ”which ID is 002 into a new ngerprint.After the change,the ID of the new n-
gerprint still is 002 ,the enter steps are as follows:
2 333333
(old user code)
Enter admin ngerprint press nger four times
press user nger four times
Enter admin ngerprint Enter old user ngerprint
2 333333 111111 111111
Enter admin ngerprint
2 555555 333333
(admin code) (old user code)
press nger four times
eg, if your admin code is “555555“ or ngerprint and you want to change the old user nger-
print which ID is 002 into a new ngerprint.After the change,the ID of the new ngerprint still
is 002 ,the enter steps are as follows:
2 Enter admin ngerprint
2 555555 press old user ngerprint press new nger four times
press old user ngerprint press new nger four times
CHECK AND PREPARATION INSTALLTION STEPS INSTRUCTION OPERATION

E. DELETE SINGLE USER’S CODE
(THE ID NUMBER IS SORTED ACCORDING TO THE ENTRY ORDER, THE ID NUMBER OF THE FIRST USER IS 001, THE ID NUMBER
OF THE SECOND USER IS 002, AND SO ON)
Press
” 3 “ Enter ID number Press
“ ”
Enter
admin code
Press
“ ”
Enter admin ngerprint
eg, if your admin code is “555555“ or ngerprint and you want to change the old user n-
gerprint which ID is 002 into a new password”111111”.After the change,the ID of the new
password still is 002 ,the enter steps are as follows:
2 Enter admin ngerprint
2 555555 press old user ngerprint
press old user ngerprint 111111 111111
111111 111111
Enter admin ngerprint
2 555555 003
eg, if your admin code is “555555“ or ngerprint and you want to delete the user code which
ID is 003.After delete,the ID of the user code can’t unlock ,the enter steps are as follows:
2 003
About ID number:
• Admin code ID is 000.
• the rst registered user code ID is 001,the code is password or ngerprint.
eg,the rst registered user password is “666666“,001 is the ID of “666666“,the
second registered user ngerprint,002 is the ID of this ngerprint,…,the last ID is
199.
CHECK AND PREPARATION INSTALLTION STEPS INSTRUCTION OPERATION

H. NORMALLY OPEN MODE
(THERE WILL BE POTENTIAL SAFETY HAZARD AFTER USING
THIS FUNCTION ,IT IS NECESSARY TO FULLY UNDERSTAND
BEFORE USING IT.)
Press
” 4 “
Enter admin password Press
“ ”
• Release the normally open,it is the same way
that you set normally open mode. Or removing
the battery and touch the screen for several times
and then install the battery.Or reset the system,-
this two ways also can release the normally open
.under the normally open, the door can be opened
without password, just pressing hand directly.
I. QUIET MODE
(THE BUZZER WILL NOT MAKE ANY SOUND DURING OPERA-
TION AFTER MUTE)
Press
” 5 “
• Release the quiet mode :it is the same way
that you set the quiet mode.
J. VACATION MODE
(ONLY ADMIN CODE CAN UNLOCK,OTHER CODE WILL
PROMPT ERROR)
Press
” 10 “
• Disable:After removing one of the battery and
touching the keypad or Resetting the system.
Enter admin ngerprint
Press
“ ”
Press
“ ”
F. DELETION OF ALL USERS
(EXCEPT ADMINISTRATOR)
Press
” 3 “ Enter 00000 Press
“ ”
Enter
admin code
Press
“ ”
Enter admin ngerprint
G. AUTOMATIC LOCK FUNCTION
(TIME VALUE RANGE:5 SECONDS TO 30 SECONDS)
Press
” 3 “
Enter
admin code
Press
“ ”
Enter admin ngerprint
Unlock to Lock Time
value range
Press
“ ”
eg, if you want automatic locking 10s after un-
locking,the admin code is “666666 “or nger-
print,the enter steps are as follows:
6 666666 10
6 admin ngerprint 10
eg, if you want disable automatic locking ”,the
admin code is “666666 or ngerprint,the en-
ter steps are as follows:
6 666666 0
6 admin ngerprint 0
Disable Automatic Lock :Setting timevalue range to “0”.
Enter admin password
Enter admin ngerprint
Enter admin password
Enter admin ngerprint
CHECK AND PREPARATION INSTALLTION STEPS INSTRUCTION OPERATION

SPECIFICATION PARAMETER
NOTE:
1. The lock is only subjected to simple waterproong, and must not be exposed to
rain, in order to avoid damage caused by water intrusion into lines.
2. The lock is not reproof, so it is not suitable for installation on the re doors with
waterproof requirements.
3. Do not use low-quality batteries, in order to avoid damage to the power supply
system as a result of leakage.
4.The anode and cathode of the battery must be installed correctly.
5. Do not scratch the surface of the touch screen with sharp hard objects.
6. Do not wipe the lock surface with corrosive liquid, so as not to damage the plat-
ing.
7. If you forget the administrator password, you can reset the lock to restore default
settings.
8. If the lock has been used for a long time, remove the lock and apply lubricant on
the rotating part of the handle, to ensure the rotational exibility of the handle.
Other manuals for E021
1
Other Cielsa Dawn Door Lock manuals
Popular Door Lock manuals by other brands

Baldwin
Baldwin Cremone Bolt installation instructions

GU
GU BKS B-2156 Series operating instructions

Assa Abloy
Assa Abloy Sargent PE8700 Series installation instructions

Locinox
Locinox VINCI - LMKQ V2 user guide

Command access
Command access MRC1 Series installation instructions

Assa Abloy
Assa Abloy Yale Essential YDME 70 user guide