CineRAID 600 Series Manual

CineRAID 600/700 Series
RAID Subsystem
CR-R612 / CR-R616 / CR-R624
(Single Core Controller)
CR-R712 / CR-R716 / CR-R724
(Dual Core Controller)
Hardware Installation Guide
Version 1.1

Hardware Installation Guide
ii
10/01/2012
Copyright ©2011~2012
This guide and any accompanying software and firmware are copyrighted. No
parts of this publication may be reproduced, stored on a retrieval system, or
transmitted, in any form or by any means, electronic, mechanical, photocopy,
recording, or otherwise, without prior written consent except for copies retained
by the purchaser for backup purposes.
All rights Reserved- Printed in Taiwan.
Notice
We make no warranties with respect to this documentation either express or
implied and provide it "as it". This includes but is not limited to any implied
warranties of merchantability and fitness for a particular purpose. The
information in this document is subject to change without notice. We assume no
responsibility for any errors that may appear in this document.
The manufacturer shall not be liable for any damage, or for the loss of
information resulting from the performance or use of the information contained
herein
Trademarks
Product names used herein are for identification purposes only and may be the
trademarks of their respective companies. All trademarks or registered

Hardware Installation Guide
iii
trademarks are properties of their respective owners.

Hardware Installation Guide
iv
R
R
Re
e
eg
g
gu
u
ul
l
la
a
at
t
to
o
or
r
ry
y
y
i
i
in
n
nf
f
fo
o
or
r
rm
m
ma
a
at
t
ti
i
io
o
on
n
n
For Europe
This drive is in conformity with the EMC directive.
Federal Communications Commission (FCC)
Statement
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules.
Those limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of
the following measures:
Reorient or relocate the receiving antennas.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circlet different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Warning:
Ashielded-type power cord is required in order to meet FCC emission limits and
also to prevent interference to the nearby radio and television reception. It is
essential that only the supplied power cord be used.
Use only shielded cables to connect I/O devices to this equipment.
You are cautioned that changes or modifications not expressly approved by the
party responsible for compliance could void your authority to operate the
equipment.

Hardware Installation Guide
v
A
A
Ab
b
bo
o
ou
u
ut
t
t
T
T
Th
h
hi
i
is
s
s
H
H
Ha
a
ar
r
rd
d
dw
w
wa
a
ar
r
re
e
e
I
I
In
n
ns
s
st
t
ta
a
al
l
ll
l
la
a
at
t
ti
i
io
o
on
n
n
G
G
Gu
u
ui
i
id
d
de
e
e
Welcome to Hardware Installation Guide. This guide is designed to be used as
step-by-step instructions for installation of your subsystem, and covers
everything you need to know in learning how to operation, troubleshooting and
future upgrades. For the detail about how to configure your subsystem, please
refer to the Software Operation manual.
S
S
Sy
y
ym
m
mb
b
bo
o
ol
l
ls
s
s
i
i
in
n
n
T
T
Te
e
ex
x
xt
t
t
These symbols may be found in the text of this guide. They have the following
meanings.
Caution
This icons indicates that failure to follow directions could result in
personal injury, damage to your equipment or loss of information.
Note
This icon presents commentary, sidelights, or interesting points of
information.
Important terms, commands and programs are put in Boldface font.
Screen text is given in screen font.


Hardware Installation Guide
v
Contents
ABOUT THIS HARDWARE INSTALLATION GUIDE...................................V
SYMBOLS IN TEXT.................................................................................V
CONTENTS.............................................................................................V
CHAPTER 1. INTRODUCTION .............................................................1
MODEL VARIATIONS.............................................................................1
FEATURES .............................................................................................2
Front Panel Overview.....................................................................4
Rear Panel Overview......................................................................6
CHAPTER 2. INSTALLATION............................................................. 17
UNPACKING &CHECKING THE EQUIPMENT.........................................17
WHAT ELSE YOU NEED ........................................................................18
ESD PRECAUTION............................................................................... 18
INSTALLING HARD DISKS..................................................................... 18
INSTALL THE CINERAID RAID SUBSYSTEM IN A RACK ......................20
SYSTEM CONNECTION.........................................................................22
CONNECTION TO CINERAID RAID SUBSYSTEM WITH SAS JBODS.....22
TURNING ON FOR THE FIRST TIME........................................................ 24
TURNING OFF ......................................................................................25
CHAPTER 3. A TROUBLE SHOOTING .............................................26
REPLACE THE CONTROLLER................................................................ 26
REPLACING /UPGRADING DIMM.......................................................27
Specifications:...............................................................................27
CR-R600 RAID series...................................................................27
CR-R700 RAID series................................................................... 28
Installing DIMM...........................................................................28
HOT SWAPPING TO REPLACE THE FAN MODULE.................................. 29
HOT SWAPPING TO REPLACE THE POWER MODULE.............................30
APPENDIX A ..........................................................................................32
CONNECTORS
..............................................................................32
APPENDIX B........................................................................................... 34
BATTERY BACKUP MODULE (BBM)..............................................34
BBM Specifications.......................................................................34

Hardware Installation Guide
vi
Battery Backup Capacity...............................................................35
Operation ......................................................................................35
Removing the Battery Backup Module ..........................................35
APPENDIX C.
SPECIFICATIONS
.............................................36
SPECIFICATIONS...................................................................................36

Chapter 1. Introduction
1
C
Ch
ha
ap
pt
te
er
r
1
1.
.
I
IN
NT
TR
RO
OD
DU
UC
CT
TI
IO
ON
N
T
T
Th
h
hi
i
is
s
s
c
c
ch
h
ha
a
ap
p
pt
t
te
e
er
r
r
i
i
in
n
nt
t
tr
r
ro
o
od
d
du
u
uc
c
ce
e
es
s
s
t
t
th
h
he
e
e
f
f
fe
e
ea
a
at
t
tu
u
ur
r
re
e
es
s
s
a
a
an
n
nd
d
d
c
c
ca
a
ap
p
pa
a
ab
b
bi
i
il
l
li
i
it
t
ti
i
ie
e
es
s
s
o
o
of
f
f
C
C
Ci
i
in
n
ne
e
eR
R
Ra
a
ai
i
id
d
d
s
s
se
e
er
r
ri
i
ie
e
es
s
s
R
R
RA
A
AI
I
ID
D
D
s
s
su
u
ub
b
bs
s
sy
y
ys
s
st
t
te
e
em
m
ms
s
s.
.
.
Y
Y
Yo
o
ou
u
u
w
w
wi
i
il
l
ll
l
l
f
f
fi
i
in
n
nd
d
d:
:
:
A
A
A
f
f
fu
u
ul
l
ll
l
l
i
i
in
n
nt
t
tr
r
ro
o
od
d
du
u
uc
c
ct
t
ti
i
io
o
on
n
n
t
t
to
o
o
y
y
yo
o
ou
u
ur
r
r
C
C
Ci
i
in
n
ne
e
eR
R
Ra
a
ai
i
id
d
d
R
R
RA
A
AI
I
ID
D
D
s
s
su
u
ub
b
bs
s
sy
y
ys
s
st
t
te
e
em
m
m.
.
.
D
D
De
e
et
t
ta
a
ai
i
il
l
ls
s
s
o
o
of
f
f
k
k
ke
e
ey
y
y
f
f
fe
e
ea
a
at
t
tu
u
ur
r
re
e
es
s
s
a
a
an
n
nd
d
d
s
s
su
u
up
p
pp
p
pl
l
li
i
ie
e
ed
d
d
a
a
ac
c
cc
c
ce
e
es
s
ss
s
so
o
or
r
ri
i
ie
e
es
s
s.
.
.
M
M
Mo
o
od
d
de
e
el
l
l
V
V
Va
a
ar
r
ri
i
ia
a
at
t
ti
i
io
o
on
n
ns
s
s
There are twelve models in CineRAID storage subsystem series; which utilize
Quad 8Gb Fibre / dual 6Gb miniSAS as Host interface per controller, each with
12, 16, or 24 device bays. .
Model Name Host Interface Device bays Controller Numbers
CR-R624FS/D 4 x 8Gbps FC 24 bays 1 ( Upgradeable, Up to 2)
CR-R624SS/D
2x 6Gb miniSAS
24 bays
1 ( Upgradeable, Up to 2)
CR-R616FS/D 4 x 8Gbps FC 16 bays 1 ( Upgradeable, Up to 2)
CR-R616SS/D
2x 6Gb miniSAS
16 bays
1 ( Upgradeable, Up to 2)
CR-R612FS/D 4 x 8Gbps FC 12 bays 1 ( Upgradeable, Up to 2)
CR-R612SS/D 2x 6Gb miniSAS 12 bays 1 ( Upgradeable, Up to 2)
CR-R724FS/D
4 x 8Gbps FC
24 bays
1 ( Upgradeable, Up to 2)
CR-R724SS/D 2x 6Gb miniSAS 24 bays 1 ( Upgradeable, Up to 2)
CR-R716FS/D
4 x 8Gbps FC
16 bays
1 ( Upgradeable, Up to 2)
CR-R716SS/D 2x 6Gb miniSAS 16 bays 1 ( Upgradeable, Up to 2)

Hardware Installation Guide
2
CR-R712FS/D 4 x 8Gbps FC 12 bays 1 ( Upgradeable, Up to 2)
CR-R712SS/D
2x 6Gb miniSAS
12 bays
1( Upgradeable, Up to 2)
All of CineRAID is designed to support single controller and
upgradeable to two controller.
CR-R(6/7)XX(F/S)(S/D)
6:Single Core, 7:Dual Core
F: Fiber to Host, S:SAS to Host,
S:Single Controller, D: Dual Controllers
F
F
Fe
e
ea
a
at
t
tu
u
ur
r
re
e
es
s
s
The CineRAID Series RAID Subsystem is designed to meet today’s high
volume, performance storage requirements from rapidly changing business
environment. It provides a maximum data protection and exceptional
performance in a storage subsystem. Target usage ranges are set from small
business to departmental and corporate server needs. The RAID SYSTEM is
designed for easy integration, smooth data expansion and server migration.
The CineRAID series supports the following features:
Quad 8Gbps Fiber / Two 6Gbps mini-SAS ports as Host
6Gbps SAS / 6Gbps SATA backplane supported.
RAID Levels: 0, 1,1E, 3, 5, 6, 50, 60 & JBOD.
Multiple RAID selection.
Online RAID level/stripe size migration.
Online Array roaming.
Globe and dedicated Hot Spare Disk / Pass through Disk support.
Schedule Volume Check.
When connecting with JBOSs, Max 122 SAS devices.
Max 128 LUNs (volume set) per controller.
Online capacity expansion and RAID level migration simultaneously.

Chapter 1. Introduction
3
Online Volume Set growth
Support spin down drivers when not in use to extend service life
(MAID).
Instant availability and background initialization.
Automatic drive insertion / removal detection and rebuilding.

Hardware Installation Guide
4
Understanding the CineRAID RAID subsystem
Front Panel Overview
LCD Module
Function keys. ( ENT, ESC, Scroll up, Scroll Down )
Keys Descriptions
Up Arrow To scroll upward through the menu items
Down Arrow To scroll downward through the menu items
(ENT ) Enter
To confirm a selected item
(ESC) ESC
To exit a sub-menu and return to previous menu.
There are three LED indicators on the front panel. Following table provides a
summary of the meanings of these LED indicators:

Chapter 1. Introduction
5
LED Indicator
Normal Status
Problem Indication
Power On
indicator
Bright Blue
This LED does not light up after
power switched on
Fail Indicator
LED never light up
LED light up as Red.
Data Access
Indicator
Blink blue during host computer
accessing the RAID subsystem.
LED never flickers
For additional information on using the LCD panel and keypad to configure the
RAID see Software manual ”LCD Panel Configuration” on Chapter 3.
Driver Bay numbering convention
The enclosure bay numbering convention is shown in following figure. A bay is
designed to house either single 3.5-inch hard disk drive or 2.5-inch hard disk
drive.
CR-R624 / CR-R724
1 2 3 4
5 6 7 8
9 10 11 12
13 14 15 16
17 18 19 20
21 22 23 24
CR-R616 / CR-R716
1 2 3 4
5 6 7 8
9 10 11 12
13 14 15 16

Hardware Installation Guide
6
CR-R612 / CR-R712
1 2 3 4
5 6 7 8
9 10 11 12
Drive Bay
Rear Panel Overview
CR-R624FS/D Fiber-SAS/SATA RAID SUBSYSTEM

Chapter 1. Introduction
7
22 23 24 25 26 27
7 8 9 10 11 13
16 17 18 1 3 4 5 6 12 14 2 15 19 20 21
CR-R624SS/D SAS-SAS/SATA RAID SUBSYSTEM
CR-R724FS/D Fibre-SAS/SATA RAID SUBSYSTEM
22 23 24 25 26 27
7 8 9 10 11 13
16 17 18 1 3 4 12 14 2 15 19 20 21

Hardware Installation Guide
8
CR-R724SS/D SAS-SAS/SATA RAID SUBSYSTEM
1. Controller Box 1.
2. Controller Box 2
CR-R624FS/D & CR-R724FS/D : 3. FC_CH_0 & LED Indicator
4. FC_CH_1 & LED Indicator
5. FC_CH_2 & LED Indicator
6. FC_CH_3 & LED Indicator
LED Colors Indicate
FC Green Link

Chapter 1. Introduction
9
Blue + Blink Access
CR-R624SS/D & CR-R724SS/D :3. SAS CH 0 & LED Indicator
4. SAS CH 1 & LED Indicator
LED Colors Indicate
SAS Green Link
Blue + Blink Access
7. Raid Controller Status LED & Fault LED Indicator
LED Colors Indicate
Status
Green + Blink
Raid Controller OK
Fault
Red
Raid Controller Fault
8. SAS Expand Port ( Reserved)
9. SAS Expand Port 1 & LED Indicator
10. SAS Expand Port 0 & LED Indicator
LED
Colors
Indicate
SAS Green Link
Blue + Blink Access
11. Console
12. Terminal
13. LAN port
14. Battery back module (Option)
15. Power Switch
16. FAN failure indicator (Rear / Front)
17. FAN Module 1
18. FAN Module 1 latch
19. FAN failure indicator (Rear / Front)
20. FAN Module 2
21. FAN Module 2 latch

Hardware Installation Guide
10
22. AC inlet 1 & Latch
23. Power Module 1
24. AC inlet 2 & Latch
25. Power Module 2
26. AC inlet 3 & Latch
27. Power Module 3

Chapter 1. Introduction
11
CR-R616FS/D Fiber-SAS/SATA RAID SUBSYSTEM
22 23 7 8 9 10 11 13 24 25
16 17 18 1 14 2 15 19 20 21
3 4 5 6 12
CR-R616SS/D SAS-SAS/SATA RAID SUBSYSTEM
22 23 7 8 9 10 11 13 24 25
16 17 18 1 14 2 15 19 20 21
3 4 12
CR-R716FS/D Fiber-SAS/SATA RAID SUBSYSTEM

Hardware Installation Guide
12
CR-R716SS/D SAS-SAS/SATA RAID SUBSYSTEM
1. Controller Box 1.
2. Controller Box 2 CR-R616FS/D & CR-R716FS/D :
3. FC_CH_0 & LED Indicator
4. FC_CH_1 & LED Indicator
5. FC_CH_2 & LED Indicator
6. FC_CH_3 & LED Indicator
LED Colors Indicate
FC Green Link
Blue + Blink Access
CR-R616SS/D & CR-R716SS/D:
3. SAS CH 0 & LED Indicator
4. SAS CH 1 & LED Indicator
LED
Colors
Indicate
SAS Green Link
Blue + Blink Access
7. Raid Controller Status LED & Fault LED Indicator
LED Colors Indicate
This manual suits for next models
7
Table of contents
Popular Computer Hardware manuals by other brands

YASKAWA
YASKAWA VIPA System MICRO M13-CCF0000 manual

ORiNG
ORiNG PCard-E 021L-D5 Series Quick installation guide

EKF
EKF CompactPCI CC5-RAVE BIOS Quick Reference

Diamond Systems
Diamond Systems DIAMOND-MM-48-AT MM-48-AT user manual

SMART
SMART MOD IV installation instructions

Spondoolies
Spondoolies SPX36 quick start guide