Table 4-4 describes the DC power-supply module indicators and power-switch position labels.
Installing the DC Power Supply Module
The DC power-supply module has a 1150-W output with three DC voltage outputs of 50 V, 12.25 V, and
3.35 V. The module operates between -40.5 to -72 VDC. The power-supply module shares current on the
50V and 12.25 V outputs, and can only be used in a dual (redundant) hot-pluggable configuration. The
DC power-supply module operates from a single 40 A DC input circuit with at full output load of 1150
W, -40.5 VDC input, and does not exceed 33 A.
To install a DC power-supply module in the ASA 5585-X, follow these steps:
Step 1 Remove existing modules from the appliance:
a. If you are replacing AC power with DC power, remove both modules from the appliance (fan module
and power supply module, or both power supply modules) as shown in Step 1 through Step 4 in
Removing and Installing an AC Power Supply Module, page 4-13. Continue with Step 2.
b. If you are replacing a failed DC power-supply module with a new DC power-supply module, follow
the steps in Removing the DC Power Supply Module, page 4-24, and then continue with Step 2.
Table 4-4 DC Power Supply Module Indicators
Figure
Label Indicator Description
1IN OK Status of power-supply module:
•Unlit—No DC power cables connected, or DC power switch is off.
•Green—DC power cables connected and DC power switch is on.
2FAN OK Indicates status of fan module
•Unlit—Fan module failure, or DC power switch is off.
•Green—DC power cables connected, DC power switch is on, and internal
fan is running.
3OUT FAIL •Red—Output voltage failure1
1. The power-supply module has three output voltages—3.35 V, 12.5 V, and 50 V.
4ON •When this side of power switch is depressed, power is on.
5STANDBY •When this side of power switch is depressed, device is in stand-by mode.