• Changing the lamp
Open the projector, loosen the two
side nuts (20) of the lamp to be
changed and remove it from the sup-
ports (21). Remove the new lamp from
its box, loosen the two side nuts (20)
and locate the lamp in the supports
(21). Finally, retighten the nuts.
• Changing the colour filters
Having opened the projector,
identify the filter to be
changed, grip firmly between
thumb and forefinger and push
against the spring clip (23)
until free of the fixed clips (24).
Bend the filter outwards and
remove.
Offer the new filter to the
spring clip (23) and anchor
behind the two fixed clips (24).
IMPORTANT: for uniform distribution of
the light beam, the lamp must be posi-
tioned so that the glass pip (22) on the
bulb does not coincide with the optical
axis of the projector. With this in mind,
locate the pip as high up as possible.
CAUTION: The proje tor uses a high pressure lamp with external starter.
- When fitting a new lamp, read the manufa turer's instru tions arefully.
- The lamp must always be hanged without delay if damaged or deformed by
heat.
20
21
25
2726
24
23
• Installing wide angle lenses
Remove the projector front
cover. Unscrew knobs (25),
rotate the front lens plate (26)
from the parking position to
the operating position in
alignment with the projector
axis and then perform the
same operation with the rear
lens plate (27).
Refit the knobs and secure
the two lens plates.
• Lubrication of sliding contact
parts - QS LT
To ensure perfect operation of sliding con-
tact parts of the projector, lubricate spar-
ingly at 6-monthly intervals using ernite
Lube- -AC grease.
10
20 22
MAINTENANCE
IMPORTANT: isolate the projector from the electrical power supply before com-
mencing maintenance work of any description.
The maximum temperature on the outer surface of the projector under normal
operating conditions is 90°C (194° F) for Q and Basic HMI 1200 versions, and
80°C (176° F) for the Basic HMI 575 version.
After switching off, do not remove any part of the projector for at least 10 minutes, as
indicated on the lamp change label (1).
Once this time has elapsed, the risk of a lamp exploding is practically zero. If the lamp
needs changing, wait a further 20 minutes to avoid the risk of burns. In the event of a
lamp exploding, the projector is designed to prevent fragments of glass from being
scattered. The lenses supplied with the projector must be fitted at all times, and if vis-
ibly damaged must be replaced promptly with genuine spares.
• pening the projector
Loosen knob (16) to remove the lamp access cover (17) or loosen knob (18) to
remove the front cover (19). Once the necessary work has been completed, refit the
cover and tighten with the relative knob.
8
19 18 17
16
LENS UNITS
7
GRAPHS SHOWING BEAM DATA AND ILLUMINATION VALUES
BEAM OPENING
4
6m
6m
4
2
open iris
closed iris
0
2
0” DISTANCE ft in
32’ 10” 65’ 7” 98’ 5” 131’ 3”
164' 1" 196' 10" 229' 8" 262' 6" 295' 3" 328' 1"
0” DIAMETER ft in
4’ 3” 8’ 10” 13’ 1” 17’ 5” 21’ 8” 26’ 3” 30’ 6” 34’ 9” 39’ 1” 43’ 8”
QS-LT - Wideangle objective
7,4°
0 10 20 30 40 50 60 70 80 DISTANCE m
90 100
01,32,74,05,36,68,09,3 10,6 DIAMETER m
11,9 13,3
10935 2730 1215 685 440
110120300 225 170
HMI 1200 (fc)
HMI 1200 (lux)
1,016 254 113 63.6 40.9
10.211.127.9 20.9 15.8
BEAM OPENING
0
2
4
6m
6m
4
2
open iris
closed iris
QS-LT - Standard objective
0” DISTANCE ft in
32’ 10” 65’ 7” 98’ 5” 131’ 3”
164' 1" 196' 10" 229' 8" 262' 6" 295' 3" 328' 1"
4°
0 10 20 30 40 50 60 70 80 DISTANCE m
90 100
00,71,42,02,73,34,04,6 5,3 DIAMETER m
6,0 6,7
0” DIAMETER ft in
2’ 4” 4’ 7” 6’ 7” 8’ 10” 10’ 10” 13’ 1” 15’ 1” 17’ 5” 19’ 8” 22’
33750 8437 3750 2110 1350
340415940 690 530
HMI 1200 (fc)
HMI 1200 (lux)
3,135 784 348 196 125
31.638.687.3 64.1 49.2
BEAM OPENING
0
2
4
6m
6m
4
2
open iris
closed iris
QS-ST / BASIC - Standard objective
0” 16’ 5”
DISTANCE ft in
32’ 10” 49’ 3” 65’ 7” 82’ 98’ 5” 114’ 10” 131’ 3”
11,5°
0” 3’ 3”
DIAMETER ft in
6’ 7” 9’ 10” 13’ 1” 16’ 5” 19’ 8” 23’ 26’ 3”
0 1,0 2,0 3,0 4,0 5,0 6,0 7,0 8,0
DIAMETER m
0 5 10 15 20 25 30 35 40
DISTANCE m
HMI 1200 (fc)
25600 6400 2844 1600 1000 711 520 400
HMI 1200 (lux)
2,378 595 264 149 92.9 66.1 48.3 37.2
BEAM OPENING
0
2
4
6m
6m
4
2
open iris
closed iris
0” 16’ 5”
DISTANCE ft in
32’ 10” 49’ 3” 65’ 7” 82’ 98’ 5” 114’ 10” 131’ 3”
0” 7’ 3”
DIAMETER ft in
14’ 1” 21’ 4” 28’ 3” 35’ 5” 42’ 4” 49’ 3” 56’ 5”
QS-ST / BASIC - Wideangle objective
24,6°
0 5 10 15 20 25 30 35 40
DISTANCE m
0 2,2 4,3 6,5 8,6 10,8 12,9 15,0 17,2
DIAMETER m
3950 990 440 245 160 110 80 62
HMI 1200 (fc)
HMI 1200 (lux)
367 92 40.9 22.8 14.9 10.2 7.43 5.76