Clean Logix BLX-200W User manual

USER
MANUAL
English (Original Instrucons)
Updated: 02/11/21
MODEL:
BLX-200W
Dual Manual BootScrubber (Wet)

BLX-200W Manual Page 2 of 9 Updated: 02/11/21
USER MANUAL: BLX-200W
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
The BLX-200W is an all manual, single footwear
scrubbing unit. Designed and built as a solid member,
open stainless steel frame with a solid hand rail for
support. The BLX-200W features one removable sole
brush and four removable vercal side brushes, each
of which require no tools. Being a manual based, wet
unit the BLX-200W requires no electrical and is pre-
congured for easy plumbing of water and sanizer.
Overview
▪Frame - 304 Stainless Steel
▪Length - 29 1/2in.
▪Width - 28 in.
▪Height - 42 in.
Specicaons
!
CAUTION:
1. Avoid contact of cleaning agent with skin
and eyes. If contact occurs, see MSDS sheet
for further rst aid measures.
2. Follow safety instrucons of chemical
manufacturer (MSDS).
3. Always follow plant and OSHA guidelines
about the use of hygiene equipment.
4. All personnel using this unit must be
familiar with the informaon contained
in this manual. Follow all installaon and
maintenance instrucons.
5. Always wear appropriate footwear. Secure
or remove loose items on footwear.
6. Ensure solid foong and use both hands
when operang the unit.
▪Cold Portable Water
▪ 35 PSI Minimum Pressure
▪100°F Max Temperature
Water Requirements
NOTE: A back ow preventer must be installed
in the water line for this unit. Check local
codes to ensure proper installaon
!
WARNING:
DO NOT use ammable liquids (i.e. alcohol
based soluons or similar) without diluon.

BLX-200W Manual Page 3 of 9 Updated: 02/11/21
USER MANUAL: BLX-200W
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
GeneralInstallaonOperaonAppendix
Fig. 3.1: Verify level of bootscrubber at each end
Installing and Mounng the Unit
1. Set unit in desired locaon.
2. Aspects to consider when deciding on placement:
• Clearance for entering and exing.
• Trac ow for unit operaon.
• Emergency exit paths or egress in case of
emergency.
• Head room for personnel while using the
unit.
3. Once the unit is in the desired locaon, use a
level to make sure the unit is stable and level in all
direcons [Figure 3.1]. Make sure the locaon is a
at surface.
4. Using the 4 mounng brackets located at each
corner, securely fasten the unit to the oor with
appropriate hardware for the given material (i.e.
concrete anchors and bolts) as shown in [Figure
3.2]
5. Dosing of sanizing chemicals into water supply
can be accomplished via the included venturi
injector.
Installaon
Fig. 3.2: Mounng bracket locaons
WARNING
If not properly secured to oor the unit may p
over and has the potenal to cause personal injury.
NOTE: The unit is compable with most
common sanizers. For further plumbing
recommendaons please contact Clean Logix.

BLX-200W Manual Page 4 of 9 Updated: 02/11/21
USER MANUAL: BLX-200W
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Installing Handrail
Due to the shipment size, the BLX-200 will arrive with
the handrail disconnected.
1. Place handrail through the mounng brackets on
each side of the unit [Figure 4.1].
2. Using two 1/2” wrenches ghten the bolt through
the locknut unl the bolt booms out against the
handrail to secure in place [Figure 4.2].
3. Repeat for remaining bolts to secure the handrail
(8 bolts total).
Installaon (connued)
Fig. 4.1: Installing Handrail
Fig. 4.2: Handrail stablizaon bolts

BLX-200W Manual Page 5 of 9 Updated: 02/11/21
USER MANUAL: BLX-200W
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
GeneralInstallaonOperaonAppendix
Installing Foot Plate
1. Place the Foot Plates at the opening of each end
of the unit.
2. Make sure the notches on the plate line up with
the holes on the unit, as shown in [Figure 5.1].
Installaon (connued)
Fig. 5.1: Inserng Foot Plate
Plumbing
1. Connect the water regulator on the Venturi to the
water supply line (regulator thread = 1/2")
2. Using 3/8" OD polyethylene tubing (or similar)
connect the sanizer soluon to be used to the
Venturi's hose barb, as shown below:
NOTE: A back ow preventer must be installed
in the water line for this unit. Check local
codes to ensure proper installaon.

BLX-200W Manual Page 6 of 9 Updated: 02/11/21
USER MANUAL: BLX-200W
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Installaon (connued)
Fig. 6.1: Water line of BLX-200W
Fig. 6.2: Brush clip rotaon for brush removal
Removing Brushes
1. The brushes are held in place by the brush clip at
the front of the unit.
2. To remove the brushes, pull up on the clip and
twist them outward, as shown in [Figure 5.2].
3. Once unlocked, the brushes can be removed for
cleaning, by slipping them out from their holders.
Plumbing (connued)
3. Using the push to connect ng, connect the
Venturi system to the BLX's water line located
under the unit, near one of the foot plates
[Figure 6.1].
4. Test the system by stepping on the footplate to
engage the unit and begin spraying.
5. Adjust the soluon output as necessary using the
included metering ps (instrucons included).
NOTE: Injector must be mounted within 10 .
of boot scrubber.
!
WARNING:
DO NOT use ammable liquids (i.e. alcohol
based soluons or similar) without diluon.

BLX-200W Manual Page 7 of 9 Updated: 02/11/21
USER MANUAL: BLX-200W
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
GeneralInstallaonOperaonAppendix
General Use
Prior to use - ensure brushes, handrail, and foot plates
are secured and the system itself properly installed.
To verify water/sanizer supply; step on the Foot
Plate to iniate water/sanizer ow. Before operang
the unit, ensure solid foong and use both hands on
the handrail for support.
1. To begin operaon, step up to the unit and grip
the support handrails.
2. Enter the unit from either end, placing one boot in
the brush secon and the other on the opposing
foot plate to acvate the spray system.
3. Push the boot back and forth mulple mes so
every part makes contact with the brushes.
4. Once the rst boot is clean, remove it and walk
through to the second scrubber and repeat the
process with the other boot.
5. If boots are extremely dirty, it may be necessary to
scrub them mulple mes.
Cleaning and Wash-Down
1. Shut o water supply to unit and depressurize
water lines.
2. Remove the Foot Plates and brushes from the
unit.
3. Brushes and Foot Plates can be washed,
individually, in a COP tank, or wash machine.
4. The frame can be washed down by convenonal
means.
Operaon
The following maintenance procedures are
recommended for normal use. Units which see a
high amount of daily use should be inspected more
frequently as necessary.
Weekly:
• Inspect brushes for damage or wear.
• Check for missing or deformed bristles.
• Inspect plumbing/water lines for damage
• Ensure solid mounng to oor.
Monthly:
• Check all fasteners to ensure they are ght.
• Ensure warning labels and decals are present
and in good condion.
• Inspect valve for damage
Quarterly:
• Inspect structure for cracked welds or bent
components.
Maintenance

BLX-200W Manual Page 8 of 9 Updated: 02/11/21
USER MANUAL: BLX-200W
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Appendix A - Parts Callout
Part No. Descripon
F1036 BOLT HHC 5/16-18 X 3/4 SS
F1052 NUT NYLOCK 5/16-18 SS
F1151 WASHER 37/64 X 1-1/16 X 1/16 SS
F1152 BOLT HHC 5/16-18 X 2 SS
M1262 BRUSH FIXED 10-1/2 X 3
M1388 BRUSH BOX WLDMNT
M1392 BRUSH CLIP
M1393 FIXED SIDE BRUSH
M1395 FOOT PLATE BLX-200
M1396 FRONT PLATE BLX MANUAL
M1397 HANDRAIL BLX-200
M1398 REAR PLATE BLX-200
M1399 SPRAY BAR BLX MANUAL
M1407 SPACER BLX-200
P1047 VENTURI INJECTOR 3/8 SS
P1100 PIPE HEX NIPPLE 3/8 SS
P1102 PIPE NIPPLE 1/4 CLOSE SS
Part No. Descripon
P1108 PIPE CAP 1/4" SS
P1196 PIPE COUPLER 1/4"
P1211 QUICK FIT 1/4 NPT X 3/8 TUBE
P1214 QUICK FIT 3/8" T JOINT POLYPRO
P1219 QUICK FIT 3/8 NPT X 3/8 TUBE
P1221 QUICK FIT ELBOW 1/4" NPT x 3/8" TUBE
P1248 LABEL SLIP HAZARD
P1291 QUICK FIT Y 3/8"
P1302 PIPE NIPPLE 1/4 X 3 SS
P1338 METERING TIP, LOW FLOW 100- 15KU
P1355 VALVE PUSHBUTTON SS
P1358 PIPE BUSHING 1/2 X 3/8 SS
P1398 PRESSURE REGULATOR WATER 1/2" SS
P1599 METERING TIP, CAPILLARY TUBE
Venturi Kit:

BLX-200W Manual Page 9 of 9 Updated: 02/11/21
USER MANUAL: BLX-200W
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
GeneralInstallaonOperaonAppendix
Appendix B - Dimensions
Table of contents
Other Clean Logix Scrubber manuals
Popular Scrubber manuals by other brands

Eagle power
Eagle power FASTRACTS SC12 Operation and parts manual

Nilfisk-ALTO
Nilfisk-ALTO 571 Instructions for use

Kärcher
Kärcher BD 50 C Ep Classic Operation instructions

COMAC
COMAC VISPA 35B Manual use and maintenance

FIORENTINI
FIORENTINI PINKY 26 User and maintenance manual

Clarke
Clarke Bext-100 Operator's manual