Climate RENTAL SOLUTIONS VIRUSKILLER VK401 User manual

VK401
AIR PURIFIER
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
USER MANUAL

USER MANUAL VK401 AIR PURIFIER
Page 2
READ ALL INSTRUCTIONS BEFORE USING YOUR VK 401
When using your VK 401, basic safety precautions should be observed, including the following:
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
• Use the unit only for its intended use.
• To protect against a risk of electric shock, do not immerse any part of the system in water or in any other liquids.
• This appliance is NOT a toy.
• This appliance is NOT to be used by children or persons with reduced physical, sensory or mental capabilities.
• Children should be supervised at all times.
• Never look directly at a burning ultra-violet light, as this may permanently damage your eyes.
• To reduce the risk of an electric shock or damage to the unit, switch the o and unplug before cleaning or per-
forming any maintenance to the unit.
• Heed all warnings
• There are no UV risks associated with the devices in use. The UV reactor chambers and fans are sealed to en-
sure there is no risk of harm and UV exposure. Indoor air quality sensors on the devices also highlight when the
lters on units need to be cleaned and replaced.
Dear Customer
Thank you for purchasing the VK 401 Air Purier, this is clean air technology at its best. This product is packed with
power and technology to provide fast and ecient clean air. We hope that you enjoy using your new unit!
The Viruskiller technology was tested against the following major airborne viruses: Poliovirus, Inuenza Virus, Ade-
novirus and Coronavirus DF2 by the Institute of Medical Sciences, School of Medicine National Kangwon University.
Testing proves a near 100% reduction for these viruses. The results for these airborne pathogens are the same for
all of the Viruskiller range.
Radic8’s Viruskiller range (Hextio, VK 401, VK 102 and VK 103) is not FDA-cleared / FDA-approved.

USER MANUAL VK401 AIR PURIFIER
Page 3
SUMMARY ..............................................................................................................3
INSTALLATION SAFETY.........................................................................................4
KEY PARTS AND COMPONENTS..........................................................................6
CLEANING AND MAINTENANCE...........................................................................8
REPLACING THE REACTOR CHAMBERS..........................................................10
ERROR MESSAGES ............................................................................................11
TROUBLESHOOTING ..........................................................................................12
CUSTOMER SERVICES.......................................................................................12
SPECIFICATIONS.................................................................................................13
SUMMARY

USER MANUAL VK401 AIR PURIFIER
Page 4
Should the unit emit smoke,
unusual odors or make any
strange noises, immediately
switch off the unit unplug it.
Contact your distributor.
Make sure the power cord is
If the power is not plugged
in correctly, this may cause
materials near the unit, as this
Do not touch the plug with
wet hands, as this may cause
serious injuries.
Do not sit, stand or place heavy
objects on the unit, as this may
result in injury and/or damage
to the unit.
Do not block the air inlet of
the unit, as this will reduce
performance and damage the
unit.
Do not move the product while
it is switched on. as this may
shock.
No form of water or liquid
should enter the unit. Should
this occur, immediately switch
off the unit and unplug it.
Contact tact your distributor.
Do not place any heavy objects
on the power cord as this may
shock.
123
6
9
8
7
45
INSTALLATION SAFETY

USER MANUAL VK401 AIR PURIFIER
Page 5
Switch the unit OFF, when
cleaning a room.
After cleaning, it is important
to ventilate the room properly
before switching the unit back
ON.
Position the unit at least 3
meters away from the bed,
to avoid excessive cooling
caused from sleeping in direct
-
ted or obstructed,
by large items such as fur-
niture, electronic items or
curtains.
Use a dedicated power outlet.
Lightning or static electricity
could affect the circuit and
the unit. To avoid this, plug the
unit into a dedicated, grounded
outlet.
Do not alter or modify the plug
or cord of this unit as it could
shock.
To protect against a risk of
electric shock, do not immerse
any part of the system in water
or in any other liquids.
Do not attempt to repair or
replace any part of this equip-
recommended in this manual.
All other services should be re-
Plug the unit into a 220V AC
outlet only, if unsupervised, it
may cause an electric shock.
Use the proper power cable
and outlet, do not over-load
the outlets with several cords
simultaneously.
Keep the product away from
other combustible substan-
ces, as this could cause an
explosion.
220V
10
13
16
19
11
14
17
20
12
15
18
21
Daily room ventilation for at
least 30 minutes.
The unit is designed to purify
your indoor air and will do this
effectively when used correct-
ly. Good indoor air quality also
requires room ventilation. We
recommend opening windows
and doors, or operating the
air conditioning, for a least 30
minutes a day.
Switch the unit OFF, while
cooking.
Oils released while cooking
may reduce the life span of the
unit. After cooking, the room
must be ventilated to remove
oils. You may now switch the
unit ON to remove any smells.

USER MANUAL VK401 AIR PURIFIER
Page 6
Display and Monitoring
Filter Case
Remote Control Sensor
Display and Monitoring
Power button ON/OFF Fan Speed
Mode
(mood lamp)
THE UNIT
DISPLAY AND MONITORING
Name Function
Remote Control Sensor Point your remote control at the sensor in order to use your remote operate the unit.
Display and Monitoring Changes the information displayed on the LED in the following order: UV Lamp Time, Current
Temp, Fan Speed.
Power button ON/OFF To switch the unit ON/O. You will hear a beep sound.
Fan Speed Hold the “Up” button down to increase the fan speed. Hold the “down” button to decrease the
speed. Fan speeds: FAN 1 (Quiet), FAN 2 (Normal), FAN 3 (High Speed).
Mode (Mood Lamp) Hold the “lamp” button down for a few seconds in order to switch the LED lights ON/OFF.
KEY PARTS AND COMPONENTS

USER MANUAL VK401 AIR PURIFIER
Page 7
1) Power On/Off
7) Mood Lamp On/Off
4) Mode
5) Timer -
6) Timer +
2) Fan Speed Up
3) Fan Speed Down
REMOTE CONTROL
No. Name Function
1. Power On/O To switch the unit ON/O. You will hear a beep sound.
2. Fan Speed Up Increases the fan speed. Fan speeds: FAN 1 (Quiet), FAN 2 (Normal), FAN 3 (High Speed)
3. Mode Decreases the fan speed.
4. Fan Speed Down Changes the information displayed on the LED in the following order: UV Lamp Time, Current
Temp, Fan Speed
5. Timer - Sets a working time for the unit. The unit will stop after the specied time has passed.
6. Timer + Sets a working time for the unit. The unit will stop after the specied time has passed.
7. Mood Lamp On/O Used to switch the blue LED Lamp ON/OFF on the unit.

USER MANUAL VK401 AIR PURIFIER
Page 8
CLEANING THE PRE-FILTER
1
2
34
5
Ensure that the unit is switched OFF and unplugged. We recommend you check the pre-lter regularly and clean it
on a weekly basis. The plastic pre-lter is reusable, to clean it follow the procedure below:
• Open the handle at the top of the unit ①. Gently slide the lter case out of the top of the unit ②..
• Slide out and separate the pre-lter ③ from the HEPA lter ④. Ensure you have removed the HEPA lter be-
fore washing the pre-lter.
• Clean the pre-lter by using a vacuum cleaner. Cleaning with warm water is also possible, however allow the
lter to dry completely before reinstalling.
You can now put the lters back into the case and place this back into your VK 401. Make sure that the carbon part
of the lter is facing the back on the unit. Close the lter handle, and the unit can be switched back on.
REPLACING THE SIDE CARBON FILTERS
Ensure that the unit is switched OFF and unplugged, unscrew and open the side lter door ⑤and replace the carbon
lter inside, then close the door, reinsert the screw and tighten.
The HEPA and Carbon lters are not reusable and should be replaced. Please contact your distributor to purchase
replacement HEPA and Carbon lters. Depending on the levels of pollution, the lifetime of the HEPA lter may be
longer or shorter than the recommended use times below:
CLEANING AND MAINTENANCE

USER MANUAL VK401 AIR PURIFIER
Page 9
Reactor cell (hrs) 8000 2000 6000
UVC lamps
REPLACING THE HEPA FILTER
The HEPA lter is not reusable and must be changed after 2000 hours of use. The display panel will indicate a “FILt”
warning. In order to change the HEPA lter refer to Figure 1, and follow the instructions below:
1. Open the handle at the top of the unit ①. Gently slide the lter case out of the top of the unit ②.
2. Slide out and separate the pre-lter ③ from the HEPA lter ④
3. Safely dispose of the old lter by placing it in a bag and sealing it.
4. Replace with the new HEPA lter
5. Place the lters back into the unit. Close the handle, and the unit can be switched back on.
6. Press and hold the “up” switch on the unit for 14 seconds, to reset the lter warning timer. Now your unit is ready
for the next 2000 hrs.
1
2
34

USER MANUAL VK401 AIR PURIFIER
Page 10
In order for the VK 401 to remain functional the reactor chambers must be replaced every 8000 hrs. Your unit will
indicate that a change is required, “-001” displayed on the LCD.
1. Switch o, and unplug the unit.
2. Remove the 12 screws at the back of the unit.
3. Place the unit on its back, and carefully lift open
the front of the unit. (make sure no wires are dis-
connected when lifting the front cover)
4. Remove the black and white cable linked to the
reactor chambers. (marked J5 on the PCB)
5. Remove the 4 corner screws out of both the
chamber mountings, being careful to ensure that
the earth wire (yellow) closest to the switchboard
is detached and remains intact.
6. Remove the old reactor chambers and replace
with the new chambers which are already linked
together, then return the 4 screws to the corners
of each chamber, ensuring that the earth wire is
reconnected to the screw closest to the circuit
board, and then connect the new reactor cable to
the circuit board.
7. Close the unit carefully making sure that no wires
are trapped or damaged, return the 12 screws to
the back of the unit.
8. Now switch your VK 401 back on, press and hold
the down button for 14 seconds, to reset the warn-
ing timer. Now your VK 401 is ready for the next
8000 hours.
REPLACING THE REACTOR CHAMBERS

USER MANUAL VK401 AIR PURIFIER
Page 11
Reactor Cell change
UV Lamp malfunction
Circuit overheat error
Fan error
The lifespan of the Reactor Cell is 8000 hours of use. When this time has passed,
the timer on the unit will display with a minus (-). When you see this warning
message, it is time to replace the Reactor Cell.
This is an error message that refers to a malfunction of the UV lamps. Turn the
unit off and contact customer service.
This is an error message that refers to overheating of the circuit board. Turn the
unit off and contact customer service.
This error indicates that the fan is not working properly. Turn the unit off and
contact customer service.
1
2
3
4
ERROR MESSAGES

USER MANUAL VK401 AIR PURIFIER
Page 12
Before you call for service, review this list. It may save you time and expense. This list includes common occurrences
that are not the result of defect in workmanship or materials.
Problem Possible cause Solution
The product will not turn on
• The plug is not properly insert¬ed in the
grounded outlet.
• The remote control is out of battery power
• The voltage of the AC outlet is too low
• Plug the device into a working grounded
outlet.
• Replace the batteries according to the
polarity.
• Make sure you plug the unit into its
dedi¬cated, grounded 220 AC outlet.
Weak airow and noise from the
product. The pre-lter has accumulated too much dust. Clean the pre-lter to avoid this problem Also
change the HEPA lter when due.
The timer preset does not work. The timer function has not been activated. Set the timer, according to the instruc¬tions in
this manual.
The air purifying function does not
work properly.
• The indoor air is heavily
• contaminated
• The pre lter is blocked
• The HEPA lter is blocked
• The room is too large for the unit
• The airow is restricted
• The room requires ventilation.
• Clean the pre lter.
• Replace the HEPA lter.
• Select the right Viruskiller according to the
room size.
• Make sure there is enough clearance
around the product and that the air inlet
and outlet of the unit are unobstructed.
Strange smell is emitted from the
device.
• New product odor
• Moist lters
• The product has been used in
environments with a high con¬centration
of food odours.
• The product has been used in
environments with a high concentration
of smoke.
• The coating of the reactor cell might
re¬lease a small amount of harmless
odor. It should disappear in one to two
weeks.
• When cleaning the pre-lter with water,
make sure it is completely dry before
reinstalling.
• Food odors are oily and can penetrate
into the lter or the reactor chamber. Use
proper ventilation.
• In areas emitting too much smoke, the
performance of the reactor cell may be
aected. Use proper ventilation.
CUSTOMER SERVICES
distributor if you encounter issues with your unit or to procure replacement lters or reactor chamber when these
reach their end of life.
Damage or malfunction caused by negligence, abuse, unauthorized repairs or use not in accordance with the User
Guide will not be covered. All warranties are rendered void and the cost of repair will be payable by the user in the
case of damages caused by:
• putting in foreign objects (such as water, liquids, fragrance oils, toys etc.) in or out of the unit;
TROUBLESHOOTING

USER MANUAL VK401 AIR PURIFIER
Page 13
• transportation or handling;
• use of products such as benzene or thinners;
• incorrect power supply or output voltage;
• breakdown or loss of part caused by unauthorized disassembling or modications;
• repair or replacement undertaken by unauthorized persons;
• non-adherence to the instructions provided in this user guide, and as given by the local customer service center;
• careless or improper use;
• caused by operating the product in a corrosive or moist environment.
SPECIFICATIONS
The company reserves the right to make changes to the design and specications of the product without prior notice.
Description Air Purier
Brand VIRUSKILLER
Model No VK 401
Max. Elec. Consumption 140 watt
Net Weight 12.9 Kg
28 Lbs
Net Dimensions 365 H x 170 D x 590 W
mm
14.4 H x 6.7 D x 23.2 W in
Noise (dB) 46-54
Airow (CFM) 70 – 141
UVC Lamps 8
TiO2 Hexagon Filters ~30
Power cord length 1.2 m
4 ft

USER MANUAL VK401 AIR PURIFIER
Page 14
To replace a uorescent tube:
1. Disconnect the cabinet from the mains power supply.
2. Remove the sign panel by starting at one of the top corners and pulling the sign panel out from under the sign
top cover (see Figure 7 below).
3. The uorescent tube can now be removed. Revolve the tube until the pin position allows withdrawal (see Figure
8 below).
4. When retting the sign panel, ensure the panel engages into the sign top along the full length of the sign unit and
both the sign end strips t neatly into the top and bottom corner notches.
Figure 8:
Replacing the Fluorescent Tube
Fluorescent Tube
Figure 7:
Removing Sign Panel
Sign Top Cover Sign EndS trip
Sign Panel

USER MANUAL VK401 AIR PURIFIER
Page 15
Cabinet Interior Light
The cabinet interior side light is tted with one 35Watt T5 uorescent tube (Ø16mm x 1450mm, Daylight 840), which
may be replaced without removing shelves or product from the cabinet. To replace the uorescent tube:
1. Disconnect the cabinet from the mains power supply.
2. Remove the side light diuser, by compressing the back section of the diuser until it disengages from the alu-
minium housing and then push the diuser back (see Figure 9 below).
3. The uorescent tube can now be removed. Revolve the tube until the pin position allows withdrawal.
4. When retting the new uorescent tube ensure the printing on the tube is at the bottom, as the tube orientation
is important. The replacement tube must be of the same wattage and colour rendering as the original.
5. When retting the diuser, engage the back section into the housing and then compress and snap the front sec-
tion of the diuser into place, working down the full length of the housing.
Figure 9: Cabinet Interior Light
Fluorescent Tube
Diffuser