Climatouch CTO-7TC-32ADH User manual

2-YEAR WARRANTY
www.CLIMATOUCH.com
INSTRUCTION MANUAL
Climatouch™CT0-7TC-32ADH
3 Heating and 2 Cooling with Automatic Humidity Control and Dual Fuel Switch

INSTRUCTION MANUAL
OOUUTTDDOOOORR WWIIRREELLEESSSS TTEEMMPPEERRAATTUURREE
TTRRAANNSSMMIITTTTEERR AANNDD RREECCEEIIVVEERR KKIITT
Climatouch™Part No. 90064
Outdoor Wireless Temperature
Transmitter and Receiver Kit Includes:
Transmitter
Antenna
Receiver Module
2 AA Batteries
U.S. Patent: 6,902,117
Accurately Displays
Current Outdoor Temperature
on t e Climatouc ™T ermostat and
Enables Dual Fuel and
Automatic Humidity Capability

TABLE OF CONTENTS
5INSTRUCTION MANUAL
TABLE OF CONTENTS...............................................................................................5
GLOSSARY OF TERMS...............................................................................................6
SELECTING A LOCATION...........................................................................................7
MOUNTING CLIMATOUCH™ TO THE WALL .............................................................8
WIRING LEGEND .......................................................................................................9
WIRING DIAGRAMS............................................................................................10-15
HOME SCREEN........................................................................................................16
CONTROL SCREEN .................................................................................................17
THERMOSTAT OPERATION MODES ........................................................................18
TEMPERATURE CONTROL MODES.........................................................................19
AUTOMATIC HUMIDITY CONTROL ..........................................................................20
HUMIDIFY AND HUMIDITY SETPOINT ....................................................................21
DE-HUMIDIFY AND HUMIDITY SETPOINT ..............................................................22
FAN OPERATION MODES ........................................................................................23
MENU SCREEN ..................................................................................................24-25
DATE AND TIME SETTINGS.....................................................................................26
PROGRAM SETTINGS..............................................................................................27
ENERGY WATCH ......................................................................................................28
SET SCREEN OPTIONS............................................................................................29
VACATION MODE .....................................................................................................30
FILTER MONITOR ....................................................................................................31
ADVANCED SETTINGS - FEATURES SETTINGS ................................................32-33
ADVANCED SETTINGS - SYSTEM CONFIGURATION...............................................34
ADVANCED SETTINGS - DUAL FUEL SWITCH........................................................35
ADVANCED SETTINGS - DIFFERENTIAL SETTINGS...............................................36
ADVANCED SETTINGS - TIMER FEATURE..............................................................37
ADVANCED SETTINGS - HEAT PUMP ....................................................................38
ADVANCED SETTINGS - HUMIDITY SETTINGS .................................................39-41
ADVANCED SETTINGS - CALIBRATION.............................................................42-43
SIMPLE THERMOSTAT MODE .................................................................................44
TROUBLESHOOTING ...............................................................................................45
IMPORTANT NOTICE ..............................................................................................46
WARRANTY..............................................................................................................47
Climatouch™CT0-7TC-32ADH
Introducing the Climatouch™CT0-7TC-32ADH touch-screen thermostat with
3-stage heating, 2-stage cooling control, an automatic humidity controller and
fossil fuel switch (available only when combined with Climatouch™Outdoor
Wireless Transmitter and Receiver Kit. Climatouch™Part o. 90064)
:: 7 Day programmable with 4 events
per day - including fan
:: Large, easy to read dot matrix display
:: True touch screen technology
:: Automatic selection of cool
or heat mode
:: Programmable fan mode
:: Programmable filter monitor
:: Programmable installer message
:: Configurable humidification relay
:: Independent de-humidification relay
:: Customizable full and partial
lock security
:: Adjustable differential settings
for multistage installations
:: Energy watch calculates kWh con-
sumption and real time HVAC cost
:: Simple mode for
non-programmable usage
:: Programmable Vacation Mode
CCOOMMFFOORRTT
CCOONNVVEENNIIEENNCCEE
CCOONNTTRROOLL

SELECTING A LOCATION
7INSTRUCTION MANUAL
Install your Climatouch™thermostat approximately 5 feet (1.5 meters) above the
floor in an area with good air circulation.
Avoid the following locations:
:: Hot or cold air from ducts
:: Radiant heat for appliances or sun such as a skylight
:: Unheated or uncooled areas: for example an outside wall behind the thermostat.
:: Ensure that there is no furniture directly below or beside the thermostat.
GLOSSARY OF TERMS
6Climatouch™CT0-7TC-32ADH
CYCLE RATE - Cycle rate is the frequency that heating or cooling equipment is
turned on during a certain period of time. Cycle rate is often given in units of cycles
per hour (CPH).
DEHUMIDIFY - The process of removing moisture from the air.
DEHUMIDIFIER - Device used to remove moisture from the air.
DIFFERE TIAL - Differential is defined as the difference between the cut-in and
cut-out points as measured at the thermostat under specified operating
conditions. For example, if the thermostat turns the heating equipment on at 70
degrees F and turns the heating equipment off at 74 degrees F, then the differential
is 4 degrees F.
HUMIDIFIER - A device used to add moisture to a space.
HUMIDISTAT - A control which is operates the humidifier and is affected by changing
humidity.
HUMIDITY - Moisture in the air.
PROGRAMMABLE THERMOSTAT - A thermostat with the capability of automatically
adjusting temperature set point to pre-selected settings at pre-selected times.
SETBACK - The automatic alteration of the thermostat control point(s) by means
other than manually changing the temperature set point.
SET POI T - The desired temperature setting on an electromechanical or
electronic thermostat.

WIRING LEGEND
9INSTRUCTION MANUAL
24V (RED)
2nd Stage Heat
1st Stage Heat (WHT)
Fan (GRN)
AC (YLW)
COMMON (BLUE)
TERMI AL EQUIPME T STA DARD COLOR
Y1 First Heat Pump and AC Yellow
G Fan Green
W2 First Stage Furnace White
OBW Reverse Valve - Second Stage Furnace Orange
RH 24v Red
Y2 Second Heat Pump and AC Unknown
C Common Blue
H Humidity Control Unknown
DH Dehumidify Control, Variable Fan Control Unknown
RC 24v Unknown
11 and 12 Not Used
OTE: The above colors are standard in HVAC industry. The wiring should be
confirmed before installation
MOUNTING CLIMATOUCH™TO THE WALL
8Climatouch™CT0-7TC-32ADH
1. Make sure to turn off the power supply located at the electrical service panel.
All heating and cooling units should be OFF.
2. Separate the backplate from the thermostat by grasping the unit firmly at the
bottom lip and pulling gently until the two piece are apart.
3. Align the backplate to the wall.
4. Mark the three locations for drilling the 3/16” holes required for the plastic
screw anchors.
5. Remove the backplate and drill the three 3/16” holes in these locations.
6. Insert the plastic gyproc screws and ensure that they are snug in the wall.
7. Securely mount the backplate to the wall with the 3 supplied screws.
8. Make the appropriate wire connections based on the specifications of the
household HVAC unit(s). Please refer to Wiring Table to determine the appro-
priate wire connections.
9. Place the thermostat on the backplate by firmly but gently from the top aligning
the pins with the screw terminals.
10. Turn on the electricity at the electrical service panel.

WIRING DIAGRAMS
11INSTRUCTION MANUAL
AC A D TWO HEAT
24V (RED)
Heat2
Heat1 (WHT)
Fan (GRN)
AC (YLW)
COMMON (BLUE)
AC A D O E HEAT
24V (RED)
Heat (WHT)
Fan (GRN)
AC (YLW)
COMMON (BLUE)
WIRING DIAGRAMS
10 Climatouch™CT0-7TC-32ADH
TWO AC
O E AC
24V (RED)
Fan (GRN)
AC (YLW)
COMMON (BLUE)
AC2 (YLW)
24V (RED)
Fan (GRN)
AC1 (YLW)
COMMON (BLUE)

WIRING DIAGRAMS
13INSTRUCTION MANUAL
O E HEAT PUMP A D O E HEAT
24V (RED)
Reverse Valves (ORG)
Heat (WHT)
Fan (GRN)
HP (YLW)
COMMON (BLUE)
O E HEAT PUMP
24V (RED)
Reverse Valves (ORG)
Fan (GRN)
HP (YLW)
COMMON (BLUE)
WIRING DIAGRAMS
12 Climatouch™CT0-7TC-32ADH
HUMIDITY CO TROL
24V (RED)
Hum. Wire 2 to Common
Hum. Wire 1
Common (BLUE)
AC A D TWO STAGE FUR ACE
24V (RED)
2nd Stage Heat
1st Stage Heat (WHT)
Fan (GRN)
AC (YLW)
COMMON (BLUE)

WIRING DIAGRAMS
15INSTRUCTION MANUAL
TWO TRA SFORMER
HEAT
TRAN
CUT
COOL
TRAN
O E TRA SFORMER
HEAT
TRAN
WIRING DIAGRAMS
14 Climatouch™CT0-7TC-32ADH
TWO HEAT PUMP
HP 2
24V (RED)
Reverse Valves (ORG)
Fan (GRN)
HP 1 (YLW)
COMMON (BLUE)
O E HEAT PUMP A D TWO HEAT
Heat 2
24V (RED)
Reverse Valves (ORG)
Heat 1 (WHT)
Fan (GRN)
HP (YLW)
COMMON (BLUE)

Current Room
Temperature
Current Room Humidity
Current Outdoor
Temperature
Current Thermostat
Operation Mode
Current Temperature
Control Mode
Current Fan
Operation Mode
Fan Operation Indicator
Vacation Mode Indicator
Security Indicator
Heat setpoint
Cool setpoint
Date
Time
Change the Temperature Setpoint(s) using -and +buttons.
In AUTO MODE toggle the Heat/Cool button (Heat or Cool will
flash once selected), then raise or lower setpoints as desired.
Change the Humidity Setpoint using -and +buttons.
Select the Thermostat Operation Mode by toggling thermostat
operation mode button.
Select the Temperature Control Mode by tog-
gling the temperature control mode button.
Select the Fan Operation Mode by toggling the fan
operation mode button.
Select the Humidity Control mode by toggling
the humidity control mode button.1
Access MENU SCREEN to enter into all thermostat features and settings.
Displays Installer Message to review important information.
CONTROL SCREEN
17INSTRUCTION MANUAL
>> To access the CO TROL SCREE , simply touch the HOME SCREE Screen… anywhere!
>> From the CONTROL SCREEN, you can:
HOME SCREEN
16 Climatouch™CT0-7TC-32ADH
>> To return to the HOME SCREE , simply touch icon at any time!
>> The HOME SCREEN displays the following information:
1 Available only in combination with WIRELESS OUTDOOR TEMPERATURE TRANSMITTER AND RECEIVER KIT (90064)

TEMPERATURE CONTROL MODES
19INSTRUCTION MANUAL
>> Based on your HVAC equipment Climatouch™can operate in the following temper-
ature control modes - AUTO or HEAT or EMERGE CY HEAT or COOL or OFF
AUTO - Climatouch™keeps the room temperature between the
selected HEAT and COOL setpoints by using both the cooling
and heating HVAC units.
HEAT - Climatouch™only turns on the heating units to regulate
room temperature.
EMERGE CY HEAT - Climatouch™enables the emergency heat
(if required).
COOL - Climatouch™only turns on the air conditioning to regulate
room temperature.
OFF - Climatouch™will not control temperature. Climatouch™
will continue to display the current room temperature, current
room humidity and outdoor temperature.
THERMOSTAT OPERATION MODES
18 Climatouch™CT0-7TC-32ADH
>> Climatouch™thermostat can operate in PROGRAM MODE or can HOLD a fixed
temperature.
RU PROGRAM: Climatouch™initiates the 7-day Programmable
Temperature Control Program with 4 independent events per
day. To set up a custom temperature control program with
customizable Temperature Setpoint and Fan operation mode,
refer to Section PROGRAM SETTINGS (page 27).
HOLD TEMPERATURE: Climatouch™regulates the room tem-
perature as determined by the selected Temperature Setpoint.

HUMIDIFY AND HUMIDITY SETPOINT
21INSTRUCTION MANUAL
>> HUMIDIFY SETPOI T: Allows you to increase and maintain the relative humidity
at a specific setpoint. Once you choose HUMIDIFY follow these easy steps:
:: The HUM setpoint with -and +icons allow you to lower and raise your setpoint.
*Example of the typical use of the Humi ify Function: If the current humi ity is 30% your
Climatouch™thermostat will initiate the humi ifier to function until Setpoint 50% is
reache . In or er to humi ify you must set the humi ity setpoint above the current
humi ity.
AUTOMATIC HUMIDITY CONTROL
20 Climatouch™CT0-7TC-32ADH
>> In order to reduce condensation, humidity must be controlled and air movement
must be generated. As the exterior temperature drops, the humidity level
needs to decrease if condensation is to be controlled.
HUMIDITY AUTO: Climatouch automatically adjusts the humid-
ity set point based on the current indoor temperature and
humidity as well as the current outdoor temperature in order
to maintain a maximum comfort level and eliminate conden-
sation. The automatic humidity setpoint is determined accord-
ing to the following standard humidity table.1
Setpoint Outdoor Temp in °C Outdoor Temp in °F
15% -29 -20
20% -24 -10
25% -18 0
30% -12 10
35% -7 20
40% -7 -20
HUMIDITY MA UAL: The user selects the humidity setpoint.
1 Available only in combination with WIRELESS OUTDOOR TEMPERATURE TRANSMITTER AND RECEIVER KIT (90064)

FAN OPERATION MODES
23INSTRUCTION MANUAL
DE-HUMIDIFY AND HUMIDITY SETPOINT
22 Climatouch™CT0-7TC-32ADH
>> DE-HUMIDIFY SETPOI T: Allows you to reduce and maintain the relative humidity
at a specific setpoint.
>> Please note that this feature functions in the COOL Mode only. Your Climatouch™
Thermostat must be configured to control a cooling unit such as an air conditioner
of heat pump. Once you choose De-Humidify follow these easy steps:
:: The DH SETPOI T with -and +icons allow you to lower and raise your setpoint
*Example of typical use of the De-Humi ify function: In or er to e-humi ify you must
set the e-humi ify setpoint below the current relative humi ity. Your Climatouch™will
both lower an regulate temperature to the cooling setpoint while monitoring an
lowering the room humi ity.
Since the De-Humi ify feature uses the COOL Function of your Air Con itioner or
Heat Pump, your Climatouch™thermostat will turn off the air con itioning if either the
ehumi ifier setpoint or temperature setpoint is reache - which ever comes first.
>> Climatouch™can operate the fan in one of the following three modes:
FA AUTO: The fan runs only when there is a demand for
heating or cooling.
FA O : The fan runs continuously
FA I TERMITTE T: The fan runs 10 minutes per 1/2 hour
providing a convenient way to improve air quality and save
energy.
When the fan is running, the animated fan icon will appear on
the HOME SCREE .

MENU SCREEN
Select HUMIDIFY or DE-HUMIDIFY
Control Mode by toggling the humidity
control mode button.
HUMIDIFY increases and maintains the relative humidity of the
room at a humidity setpoint selected on the CONTROL SCREEN.
DE-HUMIDIFY reduces and maintains the relative humidity of the
room at a humidity setpoint selected on the CONTROL SCREEN.
Please note that DE-HUMIDIFY feature functions only in COOL mode. Climatouch™
will regulate both the room temperature and the room humidity at the same time.
If DE-HUMIDIFY setpoint reached before the temperature COOL setpoint, the air
conditioning will turn off before the temperature setpoint is reached. This feature has
been specially designed to save energy without compromising the comfort.
Access ADVA CED SETTI GS to configure the thermostat.
To access the ADVANCED SETTINGS, hold the ADVANCED SETTINGS button for 5
seconds. Climatouch™will continuously beep for 5 seconds to indicate that you are
in the process of entering this feature.
!CAUTIO Altering the system properties in the ADVA CED SETTI GS may
affect the performance of the HVAC system and should be performed only by a
qualified installer.
25INSTRUCTION MANUAL
MENU SCREEN
24 Climatouch™CT0-7TC-32ADH
>> To access the ME U SCREE , simply touch ME U from the CO TROL SCREE .
>> From the MENU page, you can:
Access DATE A D TIME SETTI GS to enter the accurate date
and time
Access PROGRAM SETTI GS to pre-program temperature
changes during each day of the week.
Access E ERGY WATCH to display kWh consumption and the
dollar cost of operating the HVAC System
CLEA SCREE places the touch screen in a sleep mode for
15 seconds which allows you to wipe the screen with a damp-
ened cloth.
Access the SET SCREE menu to change screen properties.
Access VACATIO SETTI GS to activate the VACATION MODE
Access FILTER MO ITOR to review days of "fan run time."

27INSTRUCTION MANUAL
PROGRAM SETTINGS
PROGRAM SETTI GS feature allows you to easily and quickly
program daily temperature changes to fit your lifestyle and
reduce energy consumption. You can customize the program
for each day of the week with 4 independent temperature and fan
operation settings per day. To setup your program:
Select the DAY OF THE WEEK
Select the EVE T UMBER by toggling
the Event Number button
Choose desired FA OPERATIO
MODE by fan operation mode button.
Enter the event START TIME with
Hour/Minute and AM/PM buttons
Choose desired TEMPERATURE SET-
POI T with -and +buttons
Select the next event and repeat the
steps described above. Once finished,
select the next day of the week that you
would like to program. Climatouch™will
prompt you to copy the settings. Repeat
steps to program other days of the week.
26 Climatouch™CT0-7TC-32ADH
DATE AND TIME SETTINGS
Select the 12 OR 24 HOUR CLOCK display
by pushing the corresponding button.
Set the TIME by togggling hour, minute
and AM/PM buttons.
Set the DATE by toggling Month, Day
and Year buttons.

29INSTRUCTION MANUAL
SET SCREEN OPTIONS
:: BACKLIGHT: Select between automatic and permanent backlight for the screen.
AUTO: The screen back-light will come on only when you touch
the screen.
O : Screen will constantly be back-lit.
:: REVERSE: Select the positive or negative screen display.
O : Negative Display (Dark Background)
OFF: Positive Display (Light Background)
:: IGHT REVERSE: changes the touch screen background at night for improved
display under low-lighting conditions. Select between:
O : the screen automatically reverses the background at 9PM
and returns to the normal display at 6:00AM .
OFF: screen background is determined by REVERSE function.
:: CO TRAST: Toggle the screen contrast settings button (1-10) to select the screen
contrast that suits best your thermostat surroundings. Climatouch™recommends
the setting of 7.
28 Climatouch™CT0-7TC-32ADH
ENERGY WATCH
E ERGY WATCH feature provides a report on the energy con-
sumption and the dollar cost of operating your HVAC system
(for up to the last 255 days).
Once the cost of the kWH per compressor, furnace and fan have been entered into the
ENERGY WATCH Settings (see page 32) Energy Watch will display the consumption
as well as the real time dollar cost of the HVAC system.
Otherwise, ENERGY WATCH will display only the total time
the Compressor and the Furnace have been operating.

31INSTRUCTION MANUAL
FILTER MONITOR
FILTER MO ITOR: Displays filter usage in days
RESET: Resets filter timer (You should reset FILTER MONITOR
after changing the air filter.
When activated the FILTER MONITOR icon appears on your
HOME SCREEN - this feature must be activated in ADVANCED
SETTINGS.
30 Climatouch™CT0-7TC-32ADH
VACATION MODE
>> VACATIO SETTI GS allows you to set the temperature to a fixed setpoint during
the time you are on vacation, providing energy savings without compromising
comfort upon your return.
IMPORTA T: HEAT or COOL must be selected from the CO TROL SCREE before
entering the Vacation Settings screen.
To begin select Vacation Mode ON:
Select the START Date
Select the E D Date
Adjust the HEAT or COOL temperature setpoint: the Vacation
mode begins at 10 PM on the day of your departure and ends
at Midnight on the day of your arrival.
When the Vacation mode is active the suitcase icon appears on
the HOME SCREEN. Upon your return, the message VACATION
MODE ENDED will be displayed on the screen. Simply touch the screen, and your
Climatouch™thermostat will automatically revert to the Program Settings if you are
in RUN PROGRAM or to HOLD TEMPERATURE operation mode.

SECURITY: The security settings allow you
to protect your Climatouch™thermostat
from unauthorized use.
Turn Security O or OFF. You will be prompted to enter the
PIN. The Default PIN 1111.
To CHA GE PI , enter your new PIN and then, when prompted,
re-enter your new PIN.
Choose a security mode by toggling SECURITY MODE button:
FULL LOCK does not allow any changes unless the user enters
the PIN.
PARTIAL LOCK allows you to change only the temperature
setpoint without entering a PIN.
Enter the INSTALLER MESSAGE: (up to 42
characters) to appear at programmable
intervals. Type the message using the keyboard, and push OK
button to confirm. You will be prompted to enter the number of
months after which you would like the message to appear.
:: DAYLIGHT TIME: Choose Daylight Time O or OFF dependent on your Time Zone.
FILTER: Enter the air filter "fan run time"
information here. The Filter Monitor feature
uses this information to inform you when
to change your air filter by displaying
CHANGE FILTER icon on the HOME SCREEN.
E ERGY WATCH: Enter the HVAC system
consumption parameters (rounded off to
kW) as well as your electrical energy cost
(¢/kW) and the ENERGY WATCH feature
will display a real time totals of electrical
energy consumption and cost. To review
touch the ENERGY WATCH button on the MENU SCREEN.
*EXAMPLE: Fan 1kW, Heat Pump 1kW/ton, Furnace 5-30 kW, 7-9¢/kW
E ERGY WATCH feature will run consecutively for 255 days. If you do not enter your
information what will appear on the display is the total time the Compressor and
the Furnace have been operating.
Select temperature display in either CELSIUS or FAHRE HEIT
degrees by toggling the °C / °F button to either °C or °F.
ADVANCED SETTINGS - FEATURES SETTINGS
33INSTRUCTION MANUAL
ADVANCED SETTINGS - FEATURES SETTINGS
32 Climatouch™CT0-7TC-32ADH

ADVANCED SETTINGS - DUAL FUEL SWITCH
35INSTRUCTION MANUAL
!IMPORTA T: This feature can only be activated when used with the Climatouch™
Outdoor Wireless Temperature Transmitter and Receiver. Please install the
Climatouch™Outdoor Wireless Temperature Transmitter and Receiver before
activating this feature.
Increasing energy efficiency and reducing costs can be achieved by using the
dual fuel switch. Your heat pump can generally provide heat and comfort without
assistance to an outside temperature of just a few degrees below freezing. This
temperature is called the heat pump balance point. When the outside temperature
is above the balance point, the heat pump alone is sufficient for heating.
Once the outdoor temperature drops to the balance point the heat pump must
be assisted by your alternate energy source. When the outdoor temperature
drops below the systems normal crossover temperature (-12°C or -15°C), your
heat pump will stop operating and the alternate energy source will take over.
:: HP Cut O or OFF
:: Cut Temperature:
+/-Temperature in Celsius (-5°c to 25°c)
+/-Temperature in Fahrenheit (13°F to 41°F)
ADVANCED SETTINGS - SYSTEM CONFIGURATION
34 Climatouch™CT0-7TC-32ADH
!IMPORTA T: By inadvertently modifying system configuration settings, you
may seriously degrade HVAC system performance.
>> Choose system heating and cooling equipment - remember all you need to do
is toggle the appropriate button until the correct setting appears.
:: Choose HEAT PUMP or 2 STAGE HEAT PUMP or AIR CO DITIO I G or O
COMPRESSOR - please review the wiring table and diagram for wiring instructions.
:: Choose FUR ACE OFF (No Furnace) or ELECTRIC FUR ACE or EMERGE CY
ELECTRICAL FUR ACE (additional electric furnace which will come on in emergency
mode in conjunction with electric furnace) or GAS FUR ACE or OIL FUR ACE or
2 STAGE GAS FUR ACE; please review the wiring table and diagram for wiring
instructions.
:: CYCLE RATE: Set Maximum compressor cycles per hour. We recommend that the
factory default be maintained for optimal performance..
:: AUTO CHA GE: Set the minimum difference between Auto Mode, Heat and Cool
temperature setpoints. We recommend that the factory default be maintained
for optimal performance.

ADVANCED SETTINGS - TIMER FEATURE
37INSTRUCTION MANUAL
:: Specify the number of minutes for which Stage 1 will function until Stage 2 is
activated to help raise (or cool) temperature (if the temperature set point is not
reached). This unique function avoids excess compressor wear in the case where
the necessary temperature set point is not met through setting of the Staging
Differential. Set to “00” to disable.
ADVANCED SETTINGS - DIFFERENTIAL SETTINGS
36 Climatouch™CT0-7TC-32ADH
>> The Climatouch™CT0-7TC-32ADH allows you to control up to 3 Stages of Heating
and 2 Stages of Cooling, dependent on the type of system you have configured.
:: 1ST STAGE DIFFERE TIAL: Set temperature difference between temperature set
point and actual temperature reading before 1st stage heating or cooling is initiated.
:: 2 D STAGE DIFFERE TIAL: Set temperature difference between 1st stage initiation
and 2nd stage heating or cooling initiation.
:: 3RD STAGE DIFFERE TIAL: Set temperature difference between 2nd stage initiation
and 3rd stage heating or cooling initiation.
:: OB E ERGIZED: Reverses the Heat Pump OB Valve contact to HEAT or COOL
(manufacturer dependent).

ADVANCED SETTINGS - HUMIDITY SETTINGS
39INSTRUCTION MANUAL
>> IMPORTA T: The Automatic Humidity Control feature can only be activated
when used with the Climatouch™Outdoor Wireless Temperature Transmitter
and Receiver. Please install the Climatouch™Outdoor Wireless Temperature
Transmitter and Receiver before activating this feature.
Automatic Humidity Control: Automatic humidity control is an option that lets your
system automatically adjust indoor humidity based on current outdoor conditions.
This function minimizes destructive condensation build-up on your windows.
:: HUM FA : O - fan runs when there is an independent demand to humidify.
OFF: fan only runs when there is a demand to humidify while heating or cooling.
:: DH FA : O - fan runs when there is an independent demand to dehumidify.
OFF: fan only runs when there is a demand to dehumidify while cooling.
:: DH REVERSE: O - DH relay is normally closed when relative humidity is above
DH set point. OFF: DH relay is normally open when relative humidity is above DH
set point.
:: DH CO TROL COMPRESSOR: O - Thermostat will turn off the air conditioning
if either the dehumidify set point or the temperature set point is reached, whichev-
er comes first, both DH relay and compressor will turn off. OFF: DH relay is inde-
pendent of compressor activity (DH becomes a spare relay and can be used for a
variable speed fan or separate dehumidifier or air exchanger)
ADVANCED SETTINGS - HEAT PUMP
38 Climatouch™CT0-7TC-32ADH
:: HP O when Furnace On: Heat Pump and Furnace can operate together when
2nd stage furnace is required. HP “OFF” when Furnace On: turns off the Heat
Pump when the furnace is On (required on some gas or oil furnaces).