CNDINGTEK DF703 User manual

Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 3
Index
Disclaimer...........................................................................................................................................4
1 Overview..........................................................................................................................................5
2 Modify Device Parameters.............................................................................................................5
2.1 Required tools......................................................................................................................5
2.2 Connect TTL to sensor........................................................................................................ 5
2.3 Send the command through the serial port software......................................................7
3 Modify LoRaWAN Parameters...................................................................................................... 9
3.1 Making sensor into debug mode........................................................................................9
3.2 Modify its configuration by AT command.......................................................................13

Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 4
Disclaimer
CNDingtek ® keep own his best the solved manual should be accurate and very
close to the configuration, protocol and installation process.The CNDingtek
reserved all the rights to modify the hard ware software and specification, color,
guide and package and other all about the devices of CNDingtek products.
Due to the manually photos of the products and printing reasons the photos in
this documents maybe different from the real released products.Please use the
released product as final reference.

Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 5
1 Overview
This document describes how to modify device parameters through the serial
port, such as detection time, cycle upload interval, full alarm threshold, battery
alarm threshold, faire alarm threshold, fall alarm threshold, and how to modify
LoRaWAN parameters through serial port, such as deveui, appeui, band
frequency, and so on.
The main steps are as follows:
1>Tools
2>Connect TTL to sensor
3>Send the command through the serial port software
2 Modify Device Parameters
2.1 Required tools
● TTL and wires; TTL is a complimentary accessory, please check it when
receiving the goods. As shown in Figure 2.1;
● Serial port software;
● DF703 device;
Note: Due to the update, the TTL appearance you may receive is inconsistent
with the picture.
Firgure2.1
Serial port software: , If you have other serial software, you can also
use it.
2.2 Connect TTL to sensor

Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 6
1Connect the TTL tool to the debug interface of DF703 device
Please referr to Figure2.4. Note: only need to make GND_DF703 to GND_TTL
when use our TTL tool.
The GND, RX, and TX positions of the DF703 device and the TTL tool are marked
in Figure 2.2 and Figure 2.3. Please refer to it.
2Connect the TTL‘s USB interface to your computer
Firgure2.2
Firgure2.3
Firgure2.4
GND
GND
DF703 device
TTL to USB tool

Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 7
Firgure2.5
2.3 Send the command through the serial port software
After completing the two steps 2.1 and 2.2, you can refer to this step to configure
the corresponding parameters through the serial port software.
Step1 serial port software setting
COM Num.: You can check the port number used in "Device Manager -> Port"
on your computer
Baudrate: 115200
Parity bit: NONE
Data bit: 8
Stop bit: 1
Note: Do not select the "Receive as hex" option.
As shown in Figure 2.6:

Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 8
Firgure2.6
Step2 Power DF703 device on
Connect battery or you can restart DF703 device by magnet if you have powered
it on before.
Step3 Send command
When the serial port starts to output device information,you can send command
in ASCII. If the configuration is successful, you can receive a reply from sensor.
For example:
Note: The following commands are reference examples, please refer to the
product protocol documentation for a more detailed description of the
commands.
Example 1 Configure the periodic upload interval to 10h
Command in ASCII: 80029999010A81
Reply from sensor: UPloadTime: 10 h
Note: The reply means modify this configuraiton successfully.

Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 9
Notes:
1 After the device enters the sleep state, the device cannot receive the command; Please restart
the device by magnet and send the command again.
2 If the serial port does not output any information after the device is powered on or restarted,
and the parameters cannot be configured; you can check whether the TTL is correctly connected
to the device. If the RX and TX are connected incorrectly, the parameters cannot be configured.
3 Modify LoRaWAN Parameters
Steps:
1>Connect TTL to sensor
2>Making sensor into debug mode
3>Sending AT command to modify configuration
Please connect the TTL to sensor according part2.1 and 2.2, then start making
sensor to debug mode and modify its configuration,such as deveui, appeui, band
frequency and so on.
3.1 Making sensor into debug mode
1> cycle send @ in 50ms
Command
Reply

Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 10
2> Restart DF703 device by magnet.
3> After restarting sensor, you will receive the information from sensor, then
Please enter 3,

Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 13
3.2 Modify its configuration by AT command
In the debug mode, you can use the AT commands to modify configuration
(deveui, appeui, appkey, band and so on)
For example: Reading devaddr, deveui and appeui
Command: AT+ID
Enter the command in the serial port software, click Enter, and click Send, as
shown in Figure
Command response:
+ID: DevAddr, 00:00:37:2F
+ID: DevEui, 8C:F9:57:20:00:00:37:2F
+ID:AppEui, 8C:F9:57:20:00:00:00:00
Note:
1 If you need to configure other LoRaWAN parameters, such as DevEui, AppEui,
etc., send the corresponding command on this serial port. Only need to change
the command, please refer to the LoRaWAN module AT command manual to find
your needs.
2 After configuring the LoRaWAN parameter and restarting the device with a
magnet, you can exit the debug mode to make it work in normal mode.
Other manuals for DF703
1
Table of contents
Popular Security Sensor manuals by other brands

XFARM
XFARM xNode Soil quick guide

Tecnosystemi
Tecnosystemi Toolsplit 11132315 user manual

STEINEL
STEINEL True Presence COM1 manual

Lince
Lince ZENITH GOLD 869 Series Installation, operation and maintenance manual

Kitagawa
Kitagawa 121SE instruction manual

HENAN HANWEI ELECTRONICS CO., LTD
HENAN HANWEI ELECTRONICS CO., LTD WD6200 Operation manual

klemko
klemko IB-06L Installation and operating instructions

Heitronic
Heitronic 42207 Installation and operating instruction manual

Pfeiffer Vacuum
Pfeiffer Vacuum ASM 340 operating instructions

Politec
Politec Parvis Solar SMA INSTALLATION AND MOUNTING MANUAL

PIEPS
PIEPS iProbe Carbon Series manual

Wise
Wise RL Series manual