1.1 Disconnect the power supply of all electronic components.
1.2 Ensure all the components are correctly connected.
1.3 Connect all the components according to “Access Controller Wiring Diagram”
on the right of this page.
1.4 Reconfirm that all the components are correctly connected.
1.5 Switch on the power supply of both the computer and the controller and start
commissioning. For commissioning procedures, please refer to Access Controller
Installation Manual.
2.1 Connect the system according to the instructions described in this manual.
2.2 Please use the specified power supply.
2.3 Please do not touch PCB components as this will invalidate warranty
2.4 When installation is completed, please check: Is the connection correct; Is there any
short circuit or open circuit; Is the back of controller completely separated from
conductive materials.
Notice: M controller series work with Code security management software only.
Failure to follow the instructions below may lead to the malfunction of the system.
INSTALLATION PROCEDURE ACCESS CONTROLLER WIRING DIAGRAM
Important Notices
In the diagram, all the alarm outputs are
connected in normal open mode. Normal close
mode can be selected as optional.
LED Indicator:
LED1: Lock-1 Controlled Indicator
LED2: Door-1 Magnet Alarm Indicator
LED3: Lock-2 Controlled Indicator
LED4: Door-2 Magnet Alarm Indicator
LED5: Alarm Output-1 Indicator
LED6: Alarm Output-2 Indicator
LED7: Alarm Output-3 Indicator
LED8: Alarm Output-4 Indicator
POWER: Power Indicator
RD-OK: Reader Interface Indicator
Please note all relays are programmable
Four Door One Way
BUZZER/YELLOW
The Controller can be defined as Two- door
two-way reading or Four-door One-way
reading. The detail information about
controller interface. Please refer to picture 1
and picture 2.
Please note: Connect
YELLOW wire if buzzer is to
be active when LED is green
Reader Function Controller
Black GND RD-
Red +12V RD+
Green DATA0 D0
White DATA1 D1
Blue LED BUZ
Yellow BUZZER BUZ