Coemar ProSpot 575 LX User manual

1st edition, february 2002
instruction
manual
ProSpot 575

Index
1. Packaging Pag. 3
2. Transportation ,, 3
3. Important safety information ,, 4
4. Lamp: installation and replacement ,, 5
5. Operating frequency and voltage ,, 7
6. Installation ,, 8
7. Mains connection ,, 9
8. Signal connection ,, 10
9. Powering up ,, 11
10. DMX addressing ,, 12
11. Display panel functions ,, 13
11.1 Turning on the ProSpot 575 LX without articulated movement ,, 14
11.2. Resetting the counter ,, 14
11.3. test ,, 14
12. DMX 512 signal functions ,, 15
12.1 Iris diaphragm function ,, 17
13. Aligning the lamp in the optical system ,, 18
14. Opening up the projector housing ,, 19
15. Interchanging gobos ,, 20
16.Operating voltage and frequency alteration
(Reserved for technical staff) ,, 22
16.1. Selecting the operating voltage on the autotransformer ,, 22
16.2. Selecting the operating frequency on the power supply of the ProSpot 575 LX ,, 23
17. Automatic internal functions ,, 24
18. Maintenance ,, 25
19. Electronic motor alignment ,, 26
20. Spare parts ,, 27
2
English

Congratulations on having purchased a coemar product. You have assured yourself of a fixture of the highest quality, both
in componentry and in the technology used. We renew our invitation to you to complete the service information on the
previous page, to expedite any request for service information or spares (in case of problems encountered either during, or
subsequent to, installation). This information will assist in providing prompt and accurate advice from your coemar service
centre.
Following the instructions and procedures outlined in this manual will ensure the maximum efficiency of this product for
years to come.
Open the packaging and ensure that no part of the equipment has suffered damage in transit. In case of damage to the
equipment, contact your carrier immediately by telephone or fax, following this with formal notification in writing.
packing list
Ensure the packaging contains:
1 ProSpot 575 LX
1 instruction manual
The ProSpot 575 LX should be transported in its original packaging or in a coemar approved flight case.
In order to manufacture a suitable flight case, we recommend the following simple procedure to be followed, which will
stop the articulated movement of the ProSpot 575 LX during transportation.
The following diagram illustrates coemar’s recommended construction of the internal for a roadcase to suit this fixture.
A) Padding around the entire projector, including the base, with suitable padding materials.
Polietilene
espanso/
Foam
2. Transportation
1. Packaging
3
English

Fire prevention:
1. ProSpot 575 LX utilises a Philips 575 MSD or 575 MSR/2; the use of any alternative lamp is not recommended and will
null and void the fixture’s warranty.
2. Never locate the fixture on any flammable surface.
3. Minimum distance from flammable materials: 0,5 m.
4. Minimum distance from the closest illuminable surface: 2 m.
5. Replace any blown or damaged fuses only with those of identical values. Refer to the schematic diagram if there is any
doubt.
6. Connect the projector to mains power via a thermal magnetic circuit breaker.
prevention of electric shock:
1. High voltage is present in the internals of the unit. Isolate the projector from mains supply prior to performing any func-
tion which involves touching the internals of the unit, including lamp replacement.
2. For mains connection, adhere strictly to the guidelines outlined in section 7 of this manual.
3. The level of technology inherent in the ProSpot 575 LX requires the use of specialised personnel for all service applica-
tions; refer all work to your authorised coemar service centre.
4. A good earth connection is essential for proper functioning of the projector.
Never operate the unit without proper earth connection.
5. The fixture should never be located in an exposed position, or in areas of extreme humidity. A steady supply of circulating
air is essential.
Protection against ultraviolet radiation:
1. Never turn on the lamp if any of the lenses, filters, or the carbon fibre housing is damaged; their respective functions will
only operate efficiently if they are in perfect working order.
2. Never look directly into the lamp when it is operating.
Safety:
1. The projector should always be installed with bolts, clamps, and other fixings which are suitably rated to support the
weight of the unit.
2. Always use a secondary safety chain of a suitable rating to sustain the weight of the unit in case of the failure of the pri-
mary fixing point.
3. The external surface of the unit, at various points, may exceed 150°C. Never handle the unit until at least 10 minutes
have elapsed since the lamp was turned off.
4. Always replace the lamp if any physical damage is evident.
5. Never install the fixture in an enclosed area lacking sufficient air flow; the ambient temperature should not exceed 35°C.
6. A hot lamp may explode. always wait for at least 10 minutes to elapse after the unit has been turned off prior to attempt-
ing to replace the lamp.
Always wear suitable hand protection when handling the lamp.
Protection against penetration by external agents
1. The fixture is classified ordinary apparatus ; its protection grade against penetration by external agents,solid or liquid, is IP 20
3. Important safety information
4
English

ProSpot 575 LX utilises a Philips 575 MSD or a Philips 575 MSR/2 lamp at 575 watts with a GX 9,5 lampbase. The lamp is
available from your authorised coemar sales agent.
The fixture’s internal temperature can reach 250° C after 5 minutes, with a maximum peak of 350° C; ensure that the lamp
is cold prior to attempting removal. The fixture should be allowed to stand and cool for 10 minutes prior to its removal.
MSR/SA lamps are part of the mercury vapour family of discharge lamps and must be handled with great care. The lamp
operates at high pressure, and the slight risk of explosion of the lamp exists if operated over its recommended life. We rec-
ommend, therefore, that the lamp be replaced within the manufacturer’s specified lamp life.
mounting the lamps
1) Using a Phillips head screwdriver, remove the screws (A) which hold the lampholder in place, located at the rear of the
projector head. 2) Remove the lampholder assembly (B).
3) Locate the lampholder (C)
Attention
Turn off the power prior to opening up the unit.
Philips 575 MSD
coemar cod. 105215
wattage 575 w
luminous flux 43.000 lm
colour temperature 6000° K
base GX 9,5
rated life 3000 hours
Philips 575 MSR/2
coemar cod. 105245/2
wattage 575 w
luminous flux 49.000 lm
colour temperature 7.200° K
base GX 9,5
rated life 1000 hours
4. Lamp: Installation and replacement
5
English

4) Insert the lamp.
The lamp used is manufactured from quartz glass and should be handled with care; always adhere to the instructions
supplied in the lamp’s packaging. Never touch the glass directly, use the tissue provided in the lamp’s packaging. The GX
9,5 lampbase is symmetrical in construction. DO NOT USE UNDUE FORCE. In case of difficulty, re-read the instructions
and repeat the procedure.
5) Replace the lamp assembly and replace and tighten the screws (A) which were previously removed.
Attention: we recommend that the lamp be realigned in the optical train of the unit to avoid overheating of the dichroic fil-
ters and other internal components of the unit. refer to section 13 for instructions about this procedure.
6
English

The projector may operate at voltages including 115-208, 230 or 240V .at 50 or 60 Hz; coemar presets (barring specific
requests) a voltage of 230v at a frequency of 50Hz.. The preset voltage is indicated on a sticker located on the base of the pro-
jector, as shown in the diagram.
If the operating voltage and frequency selected on the projector do not match those in use in the country in which you are
operating, follow the instructions located in section 17. Altering the operating voltage and frequency.
Incorrect voltage and frequency selection will detrimentally affect the operation of the projector.
100V 115V
208V 230V
240V
50Hz 60Hz
factory set
main at:
5. Operating voltage and frequency
7
English

mounting
ProSpot 575 LX may be either floor or ceiling mounted.
For floor mounting installations, the ProSpot 575 LX is provided with four rubber mounting feet.
For ceiling mounted installations we suggest the use of appropriate clamps or fixings to attach the fixture to the mounting sur-
face.
The structure from which the unit is hung should be of sufficient rating to hold the weight of the unit, as should any clamps used
to hang the unit. The structure should also be sufficiently rigid so as not to move or shake whilst the ProSpot 575 LX
moves during its operation.
2 mounting holes of Ø13 mm (A) are located on the base of the ProSpot 575 LX allowing for the connection of G-
clamps.
safety chain
We recommend the use of two safety chains (cod. 069) - connected to the ProSpot 575 LX and to the suspension truss in
order to avoid the fixture accidentally falling. If using an after-market safety chain not manufactured by coemar, ensure that
it is of sufficient rating to hold the weight of the unit.
You may attach the safety chain to the holes (B) located on the base of the fixture, as shown in the diagram below.
protection against liquids
The projector contains electric and electronic components which should under no circumstances come into contact with oil,
water, or any other liquid. The proper workings of the unit will be compromised should this occur.
movement
The projector has a maximum movement of 385° in the base and 260° in the yoke; DO NOT place any obstructions in the
path of the projector’s movement.
risk of fire
Each fixture produces heat and must be installed in a well-ventilated position. The minimum recommended distance from
flammable material is: 0.5m. Minimum distance from the object being illuminated is: 2 m.
forced ventilation
You will note on inspection that the fixture features various air inlets and cooling fans, located on both the base and head of
the fixture. these should, under no circumstances, be blocked or obstructed whilst the projector is in operation.
Doing so could cause the fixture to seriously overheat thereby compromising its proper operation.
ambient temperature
The projector should never be installed in locations lacking a constant flow of air. The ambient temperature should not
exceed 35°C.
485mm
19,10”
6. Installation
8
English

cabling
The mains cable provided is thermally resistant, complying to the most recent international standards. It meets or exceeds VDE and IEC
norms, IEC 331,IEC 332 3C,CEI 20 35.
NB: In case of cable replacement, similar cable with comparable thermal resistant qualities must be used exclusively (cable 3x1.5
ø external 10 mm, rated 300/500V, tested to 2KV, operating temperature -40° +180°, coemar cod. CV5309).
mains connection
ProSpot 575 LX can operate at voltages from 208V-230V-240V at 50 or 60Hz (operating voltage and frequency can be
selected as described in section 5 of this manual).
Prior to connecting the unit to your mains supply, ensure that the model in your possession correctly matches the mains
supply available to you. For connection purposes, ensure your plug is of a suitable rating of 8 amps at 230V and 11 amps at
115V.
Locate the mains cable which exits the base of the unit and connect as shown below:
protection
The use of a thermal magnetic circuit breaker is recommended for each ProSpot 575 LX.
A good earth connection is essential for the correct operation of the fixture. Strict adherence to regulatory norms is strongly
recommended.
massa/ground
neutro/neutral
fase/live
marrone - brown
blu - blue
giallo/verde - yellow/green
alimentazione
main
7. Mains connection
9
English

Control signal is digital, and is transmitted via two pair screened ø0.5mm cable.
Connection is serial, utilising XLR 3 male and female sockets located on the base of the ProSpot 575 LX, labeled DMX
512 In and OUT (see diagram).
Pin connections conform to the international standard:
pin 1= screening 0 volt
pin 2= data -
pin 3= data +
If using a controller which output signal via an XLR 5 (5 pin) socket, do not use pins 4 and 5, leaving them unconnected.
Ensure that all data conductors are isolated from one another and the metal housing of the connector.
Note: the housing of the cannon XLR 3 or 5 must be isolated.
3
2
1
Controller
Standard
DMX 512
OUT
in
out
in
out
Ad altri ProSpot 575 LX
Connect to other ProSpot 575 LX
8. Signal connection
10
English

After having followed the preceding steps, turn on the DMX 512 controller which will be used to control the ProSpot
575 LX. Following this, turn on the power to the projector, and turn on the projector’s power switch. The projector will
perform a reset function on all the internal and external motors. This will last some few seconds, after which it will be subject
to the external signal from the controller.
DMX led
The DMX led will be static on to indicate that DMX 512 signal is being correctly received by the projector.
If the led is off, the projector is not receiving signal. check the cabling and the functioning of the controller.
function
display
DMX
menu enter
+
Set dmx 512 address
AOO1
enter
A001 to A493
9. Powering up
11
English

Each ProSpot 575 LX utilises 16 channels of DMX 512 for complete control. (for more details see paragraph 12. DMX
512 signal functions)
DMX coding
To ensure that each projector accesses the correct signal, it is necessary to correctly address each fixture. Any number
between 1 and 497 can be generated via the multifunction panel of the ProSpot 575 LX.
This procedure must be carried out on every ProSpot 575 LX. being used.
When powered up initially, each projector will show A001 which indicates DMX address 1; a projector thus addressed
will respond to commands on channel 1to 16 from DMX 512 controller. A second unit should be addresses as 17, a
third as 33 and so on until the final ProSpot 575 LX, has been addressed.
altering dmx addresses
1) Press the +or -button until the display shows the DMX required, the characters in the display panel will flash to indicate
that the selection is not stored in memory.
2) Press the enter button to confirm your selection; the display panel will cease to flash and the projector will now respond
to the new DMX 512 address.
3) To better understand the function of each channel, we refer you to section 12 “Control channel functions from a
DMX 512 controller”.
Important Note: Keeping the +or -button pressed will cause the display to alter at increased speed, allowing a faster
selection to be effected.
By pressing the –button, you may inadvertently select a DMX address which is not being communicated to the fixture by
the controller, for example 500. If this is the case, the display will slow the data reception, (since it does not exist), and you
will note that it is slow to respond to your commands (for example altering an address or requesting or confirming a reset).
You may solve this problem by either sending data to this address, or by altering the incorrect DMX setting of the ProSpot
575 LX. in question.
function
display
DMX
menu enter
+
Set dmx 512 address
AOO1
enter
A001 to A493
10. DMX addressing
12
English

The display panel of ProSpot 575 LX shows all the functions available; it is possible to change some of those parameters and
to add some functions. Changing the setting made by coemar can vary the functions of the device so that it will not respond
to the DMX 512 controller used to control it. Carefully follow the instructions before applying any variations or selections.
NOTE: the symbol ☞shows which key has to be pushed to obtain the function desired.
AOO1 DIRPpan movement inversion
To reverse horizontal movement direction of the beam
from left to right and vice versa on DMX level variation.
DIRTtilt movement inversion
To revert vertical movement direction of the beam from
the bottom upwards and vice versa on DMX level variation
MOVEtype of movement PAN e TILT
To choose between fast and soft Pan and Tilt movement.
IRIS iris control
To select the iris diaphragm’s control mode, by choosing
between the regular mode and the regular plus pulse
mode.
OPTOoptic sensor deactivation
To deactivate optic sensors that sense the position of th
eyoke and the base of the unit and that allow the return
in position of the unit if accidentally knocked out of place.
LAMPlamp control
Lamp on/off control inhibition by DMX signal
FAN fans control
Fans function controlleds through PCB (strd).
Fans always on (on)
DISPreverse display
Reverses display’s reading verse depending on the moun-
ting position. (on the ground or suspended)
LED display control
To disable display visualization.
TESTmotors test
Device operation test without using DMX signal
RESEreset
Reset function
DEMOdemo program
To demonstrate the fixture’s operativity
RATEDMX speed
DMX signal reception speed.
TEMP internal temperature
reading of the lamphouse’s internal temperature
HOURworking time (lamp on)
visualization of unit’s working time (lamp on) (reset not possible)
LIFElamp life
visualization of lamp life (time covered by mains supply from last
reset operation)
HTOTtotal working time
total visualization of unit's working time (time covered by mains
supply) (reset not possible)
24.S0
numeric value
0280
numeric value in hours
0600
numeric value in hours
CW
clockwise
CCW
counterclockwise
STRD
ignition by DMX 512
ON
lamp permanently on
CW
clockwise
CCW
counterclockwise
ON
sensors activation
OFF
sensors deactivation
☞
+o–
☞
+o–
☞
+o–
☞
+o–
☞
enter
☞
enter
☞
+o–
☞
+o–
☞
menu
PAN
pan movement test
ALL
motors test
STRD
automatic on/off
ON
fans always on
AA
suspended position
reversed
-– -– -– -–
reset activation
☞
enter
☞
enter
☞
enter
☞
enter
OFF
switching off display
(☞any key to reactivate it)
☞
+o–
☞
+o–
☞
+o–0550
numeric value in hours
☞
+o–
☞
+o–
☞
+o–☞
enter ☞
enter
☞
enter
☞
+o–
☞
+o–
☞
+o–☞
enter ☞
enter
☞
enter
☞
+o–
☞
+o–
☞
+o–☞
enter ☞
enter
☞
enter
☞
+o–
☞
+o–
☞
+o–☞
enter ☞
enter
☞
enter
☞
+o–
☞
+o–
☞
+o–☞
enter ☞
enter
☞
+o–
☞
+o–☞
enter ☞
enter
☞
enter
☞
+o–
☞
+o–
AA
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
+o–☞
enter ☞
enter
☞
+o–☞
enter -– -– -– -–
demo program activation
100
numeric value in C°
STRD
standard movement
SOFT
soft movement
☞
+o–☞
enter ☞
enter
☞
enter
☞
+o–
☞
+o–
PUL
pulse
LIN
regular
☞
+o–☞
enter ☞
enter
☞
enter
☞
+o–
☞
+o–
11. Display panel functions
13
English

11.1. Powering up the ProSpot 575 LX without articulated movement
This function may be useful should you need to power up the ProSpot 575 LX to re-address it or alter any parameters
and you wish to do this in the absence of any articulated movement.
1) Turn on the projector whilst holding down both the enter button and the –button.
The projector will proceed with a reset of all the motors with the exception of those which control articulated movement,
the pan and tilt motors, which remain static.
2) You may alter the DMX address, or any other parameters available via the menu system without any articulated movement.
3) To return to normal functioning the projector needs simply be turned off and then turned on once again via the power
button.
11.2. Counter reset
The lamp life counter needs to be reset to zero at every lamp change to provide accurate information on lamp life
1) Turn off the projector
2) Power up the ProSpot 575 LX whilst simultaneously holding down the +and –buttons.
3) Press the menu button.
4) Press the +or –button until the display shows LIFE(for lamp life).
5) Press the enter button to confirm your selection; the display will show 0000confirming that the counter has been reset.
11.3. test
This function allows for a test sequence to be carried out on the respective motors of the unit in the absence of any DMX signal.
1) Press the menu button.
2) Press the +or –button until the display shows TEST(for test).
3) Press the enter button to confirm your selection; the display will show PAN (for pan movement test). Press the +or –
buttons for subsequent tests from PANto ALL.
PAN= pan axis movement
TILT= tilt axis movement
DIMM= dimmer movement
SHUT= shutter and strobe
IRIS= iris diaphragm movement
FOCU= focus
GOB1= gobo 1 selection (wheel nearest the lamp)
GR1= gobo 1 fine rotation and positioning
GOB2= gobo 2 selection
PRIS= prism
COL1= color wheel 1 (closest to the lamp)
ALL= all motors reset
In these tests the projector simulates the reception of a DMX 512 signal which is increasing from 1 to 255 on the selected
channel.
4) Press the enter button to confirm your selection of test to be carried out.
14
English

If all the instructions described to this point have been followed, the 16 channels of your DMX 512 controller will allow full
control of the functions of the ProSpot 575 LX as described in the table below:
channel
function type of control effect decimal
1 Base (pan) coarse proportional coarse control of the base movement 0-255
2 Base (pan) fine proportional fine control of the base movement 0-255
3 Yoke (tilt) coarse proportional coarse control of the Yoke movement 0-255
4 Yoke (tilt) fine proportional fine control of the Yoke movement 0-255
5 dimmer step closed 0-7
proportional from close to open 8-255
6
Shutter, Strobe step Shutter closed 0-9
proportional Synchro strobe-effect from slow to fast (max. 10 flashes/second) 10-66
step Shutter open 67-68
proportional
Pulse-effect in sequences, close slow, open fast (adjustment from
slow to fast)
69-125
step Shutter open 126-127
proportional
Pulse-effect in sequences, close fast, open slow (adjustment from
fast to slow)
128-184
step Shutter open 185-187
proportional Random strobe-effect from slow to fast 188-244
step Shutter open 245-255
7 iris step open 0-9
proportional from large to small 10-124
step iris small 125-129
proportional iris pulse, with increasing pulse speed 130-189
step open 190-192
proportional iris pulse, with increasing pulse speed plus flash effect 193-251
step open 252-255
8 focus proportional proportional focus control 0-255
9
Rotating gobo,
selection step Open 0-10
step or proportional
depending on ch
gobo 1 11-40
step or proportional
depending on ch
gobo 2 41-70
step or proportional
depending on ch
gobo 3 71-100
step or proportional
depending on ch
gobo 4 101-130
step or proportional
depending on ch
gobo 5 131-160
step or proportional
depending on ch
gobo 6 161-192
proportional Gobo wheel rotation from slow to fast 193-255
10
rotating gobo 360°
indexing
step no effect 0-10
proportional proportional indexable gobo positioning 360° 11-255
11
gobo rotation & fine
indexing
proportional proportional indexable fine gobo positioning 360° 0-100
proportional
continuous gobo rotation clockwise with proportional speed
from max to min.
101-176
step
gobo stop 177-179
proportional
continuous gobo rotation counter-clockwise with proportional
speed from min. to max
180-255
12
static gobo selection step Open 0-10
step or proportional
depending on ch
gobo 1 11-40
step or proportional
depending on ch
gobo 2 41-70
step or proportional
depending on ch
gobo 3 71-100
step or proportional
depending on ch
gobo 4 101-130
step or proportional
depending on ch
gobo 5 131-160
step or proportional
depending on ch
gobo 6 161-192
proportional Gobo wheel rotation from slow to fast 193-255
12. DMX 512 signal functions
15
English

channel
function type of control effect decimal
13
prism selection &
rotation
step no prism 0-10
step prism 11-20
proportional
continuous prism rotation clockwise with proportional speed
from fast to slow
21-136
step
prism stop 137-139
proportional
continuous prism rotation counterclockwise with proportional
speed from slow to fast
140-255
14 color wheel step Open/white 0-7
step or proportional
depending on ch
color 1 8-27
step or proportional
depending on ch
color 2 28-47
step or proportional
depending on ch
color 3 48-67
step or proportional
depending on ch
color 4 68-87
step or proportional
depending on ch
color 5 88-107
step or proportional
depending on ch
color 6 108-127
proportional Forwards rainbow effect from fast to slow 128-190
step No rotation 191-192
proportional Backwards rainbow effect from slow to fast 193-255
15
gobo and color
positioning mode
step
Steps between gobos from level 11 to 192/ Steps between color
from level 6 to 127
0-10
Act on channels
9,12,14
step
From no gobo to gobo 6, 360° gobo positioning became
proportional (level 11/192)
11-125
step
From no color to color 6, 360° color positioning became
proportional (level 6/127)
126-239
step Gobo and color positioning became proportional 240-255
16
Lamp ON, motor
Reset, pan/tilt speed
control mode
step lamp off 0-10
step park, no function 11-29
step pan/tilt reset (only once) 30-65
step all motor reset except dimmer, pan, tilt (only once) 66-100
step all motor reset except dimmer (only once) 101-135
step all motor reset (only once) 136-170
step inhibit auto lens on iris 171-249
step lamp on (pan/tilt standard movement) 250-255
Back panel can modify function channel (inhibit lamp off)
note 1: function channel (16) has a delay time of 6 seconds to prevent accidental activation.
note 2 :on/off lamp mode is not affected unless an opposite value is received
16
English

12.1 Iris diaphragm functions
Via the IRISfunction, it is possible to select the iris diaphragm’s mode of control.
The possible options are:
LIN= linear; control over the iris is proportional, from maximum to minimum opening (0-255).
PUL= linear + pulse; channel number 7 will operate as per the following dmx chart:
channel function type of control effect decimal
iris step open 0-9
proportional from large to small 10-124
step iris small 125-129
proportional iris pulse, with increasing pulse speed 130-189
step open 190-192
proportional iris pulse, with increasing pulse speed plus flash effect 193-251
step open 252-255
channel function type of control effect decimal
7 iris proportional from large to small 0-255
PUL
puls
LIN
regular
☞
+o–☞
enter ☞
enter
☞
enter
☞
+o–
☞
+o–
AOO1 IRIS iris control
To select the iris diaphragm’s control mode, by choosing
between the regular mode and the regular plus pulse
mode.
☞
menu
17
English

Aligning the lamp in the optical system is achieved via the 3 adjusters at the rear of the projector. This procedure should be
undertaken to properly align the lamp in the optical system and to avoid the possible overheating of the internal compo-
nents due to the incorrect focusing of the beam onto components not intended to be exposed to this.
alignment procedure
Alignment is effected via the 3 adjusters A, Band Coperating in conjunction with each other. The lamp should be on,
black-out and dimmer fully open, and no colour filters inserted.
If the lamp is not correctly aligned, a hot-spot will be noticeable. This is a function of the lamp’s positioning. Use the two
adjusters (Band C) to bring the hot-spot to the centre of the beam. Use the third adjuster (A) to flatten the beam to maxi-
mum uniformity.
vertical adjustment
Screw (C) acts on a lever and spring assembly to position the lamp via a horizontal movement within the reflector; rotate it
until correct positioning is achieved.
horizontal adjustment
Screw (B) acts on a lever and spring assembly to position the lamp via a horizontal movement within the reflector; rotate it
until correct positioning is achieved.
axial adjustment
Screw (A) moves the entire lamp assembly axially within the unit; rotate it until correct positioning is achieved, resulting in a
flat, even beam.
A
B
C
Adjust lamp position
by turning screws
A, Band C
lamp
lamp
Caution hot lamp
Isolate electrically
before re-lamping
L
O
O
S
E
N
T
O
R
E
-
L
A
M
P
L
O
O
S
E
N
T
O
R
E
-
L
A
M
P
13. Aligning the lamp in the optical system
18
English

By removing the casing, complete access is available to the internals of the projector.
1) Loosen the screws which affix the upper and lower covers.
2) Once unscrewed, simply lift the covers to access the internal components of the fixture.
Attention
Remove mains power prior to accessing the internal components of the projector.
14. Opening up the projector housing
19
English

ProSpot 575 LX utilises a mechanical system which allows the fixture’s gobos to be removed without the need for spe-
cialised equipment.
Replacement gobos should be made of either heat resistant glass or metal.
An ever-increasing range of gobos is available from your coemar sales network.
replacing gobos
Gobo dimensions are as follows:
rotating gobo wheel
ø external = 32,9 mm
ø of image with defined edge = 28 mm
ø of image with undefined edge = 30 mm
thickness = from 0,2 to 3,5 mm
fixed gobo wheel
ø external = 32,9 mm
ø of image = 26 mm
thickness = from 0,2 to 3,5 mm
replacing gobos on the rotating gobo wheel
When replacing gobos as shown in the following diagrams, ensure that the projector is NOT powered up.
1- Open the projector housing as described in the section above, Opening up the projector housing
2- Loosen the screw as shown in the diagrams and move the metal leaf to allow easier access to the gobos
3) Release the gobo retaining spring and thereby carefully remove the gobo
4) Reverse the procedure to install a replacement gobo.
15. Interchanging gobos
20
English
Table of contents
Other Coemar Floodlight manuals
Popular Floodlight manuals by other brands

EXALite
EXALite EXL-XL Profile Zoom CW+WW 200W user manual

KAM
KAM Moonglow DMX V2 instruction manual

IB LIGHTING SUPPLY
IB LIGHTING SUPPLY FL50W-C quick start guide

Lumineux
Lumineux Carsington Plus Sports quick start guide

Griven
Griven PR 1350 owner's manual

Satco
Satco NUVO 65-541 Installation and safety instructions