IB-Lite Quick Guide
IB-Lite Quick Guide ©ComAp – December 2011 IB-Lite-Quick Guide 12-2011.pdf
ComAp, spol. s r. o.
Kundratka 2359/17
180 00 Prague 8
Czech Republic
Short guide how to start using of IB-Lite module
RJ45
Ethernet
“Restore default settings”
jumper (D)
1. What will you need?
A. One of supported ComAp controllers: IL-NT, IC-NT, MC-NT, IA-NT, InteliPro, ID-FLX Lite,
ID-Lite and their clones (more at ComAp website)
NOTE:
This document relates to controllers able to use Communication Settings directly
from the controller or relevant PC Software (LiteEdit, InteliMonitor).
IL-NT - SW 1.6*or WSUP 1.0 and higher InteliPro - SW 1.0 and higher
IC-NT - SW 1.3 and higher ID-FLX Lite - SW 1.1 and higher
MC-NT - SW 1.1 and higher ID-Lite - SW 2.0 and higher
IA-NT - N/A
Mentioned controllers with another SW are able to use IB-Lite communication
module too. Only settings need to be done by using of web browser (more in IB-Lite
Reference Guide). * Available in IB-Lite 1.7 firmware
B. UTP cable (RJ45), other network accessories (router etc.)
2. Turn off the controller (disconnect the controller from power source). Plug the IB-Lite module into the
supported controller from the back side (see the picture bellow).
PLUGGING IN OF THE IB-LITE COMMUNICATION MODULE
Tel.: +420 246 012 111
Fax: +420 246 316 647
E-mail: [email protected]
URL: http://www.comap.cz
Page 1 of 4
IB-Lite Quick Guide
IB-Lite Quick Guide ©ComAp – December 2011 IB-Lite-Quick Guide 12-2011.pdf
ComAp, spol. s r. o.
Kundratka 2359/17
180 00 Prague 8
Czech Republic
3. Choose one possibility of connection:
A. Direct connection between PC and IB-Lite
B. Connection of IB-Lite to Ethernet/Internet by using of dynamic IP and AirGate
C. Connection of IB-Lite to Ethernet by using of static IP or to Internet by using of public static IP
Ad A) Direct connection between PC and IB Lite
4. Turn on the controller.
5. Set up local network in you PC at:
•IP Address: 192.168.1.10
•Network Mask: 255.255.255.0
•Gateway IP: 192.168.1.1
Check the “Comms Settings” directly on the controller:
- Press button. Choose “Comms Settings” by using of arrows and press .
- Check “IBLite IP Addr” – should be 192.168.1.254 as default. If the IP is different change it
with , and buttons to the correct one. “IBLite DHCP” and “AirGate” has to
be DISABLED.
NOTE:
“Comms Settings” of controller can be as well changed by using of LiteEdit software via
IL-NT RS232, IL-NT RS232-485 or IL-NT S-USB communication modules.
WARNING:
Disconnect power source from the controller before exchanging the communication module!
6. Connect the IB-Lite and PC via UTP cable (it is recommended to use the crossed cable).
CONTROLLER DISPLAY:COMMS SETTINGS
7. For connection with controller use LiteEdit or InteliMonitor software or just a web browser with
putting of IP Address 192.168.1.254 (default IP) into the address bar which can get you to
embedded SCADA WebServer.
LITEEDIT:INTERNET CONNECTION
Tel.: +420 246 012 111
Fax: +420 246 316 647
E-mail: [email protected]
URL: http://www.comap.cz
Page 2 of 4
IB-Lite Quick Guide
IB-Lite Quick Guide ©ComAp – December 2011 IB-Lite-Quick Guide 12-2011.pdf
ComAp, spol. s r. o.
Kundratka 2359/17
180 00 Prague 8
Czech Republic
Ad B) Connection of IB-Lite to Ethernet/Internet by using of dynamic IP and AirGate
NOTE:
Use this possibility when you haven’t assigned static Ethernet IP address from your IT department or static
public IP from your internet provider.
4. Turn on the controller.
5. Setup “Comms Settings” directly on the controller:
- Press button. Choose “Comms Settings” by using of arrows and press .
- Setup “IBLite DHCP” and “AirGate” as ENABLED.
“airgate.comap.cz”.
- Setup. “AirGate IP” as
NOTE:
“Comms Settings” of controller can be as well changed by using of LiteEdit software via
IL-NT RS232, IL-NT RS232-485 or IL-NT S-USB communication modules.
WARNING:
Disconnect power source from the controller before exchanging the communication module!
5. Connec
- Wait a while (or turn the controller off and on).
t the IB-Lite to the router (or Internet/Ethernet socket) via UTP cable.
Tel.: +420 246 012 111
Fax: +420 246 316 647
E-mail: [email protected]
URL: http://www.comap.cz
Page 3 of 4
- Check the “AirGate ID”: Press few times button on the basic controller display until you
will see GSM/Modem status screen. Remember the AirGate ID.
CONTROLLER DISPLAY –GSM/MODEM STATUS SCREEN
te Server
0 Waiting for connection to AirGa
1 Controller registered, waiting for authorization
2 Not possible to register, controller blacklisted
3 Not possible to register, server has no more kapacity
4 Not possible to register, other reason
5 Controller registered and authorized
TABLE OF AIRGATE NOS
e LiteEdit or InteliMonitor software or just a web browser with your
upervisor.comap.cz
DIAG TIC CODES
6. For connection with controller us
WebSupervisor account (http://webs ). Connect to the controller via AirGate with
typing of the AirGate ID and using of “airgate.comap.cz” as an AirGate address (AirGate Server).
IB-Lite Quick Guide
IB-Lite Quick Guide ©ComAp – December 2011 IB-Lite-Quick Guide 12-2011.pdf
ComAp, spol. s r. o.
Kundratka 2359/17
180 00 Prague 8
Czech Republic
LITEEDIT:AIRGATE CONNECTION WEBSUPERVISOR:AIRGATE CONNECTION
Tel.: +420 246 012 111
Fax: +420 246 316 647
E-mail:
URL: [email protected]
http://www.comap.cz
Page 4 of 4
Ad C) Connection of IB-Lite to Ethernet by using of static IP or to Internet by using of public static IP
NOTE:
Use this possibility when your IT department has a Static Ethernet IP at your disposal or when the Static
Public IP from your internet provider is available.
4. Turn on the controller.
5. Setup “Comms Settings” directly on the controller:
- Press button. Choose “Comms Settings” by using of arrows and press .
- Setup items of “IBLite IP Addr”, “IBLite NetMask” and “IBLite GateIP” according to
n from your IT department (internal network) or internet provider (public network).informatio
“IBLite DHCP” and “AirGate” has to be DISABLED.
NOTE:
“Comms Settings” of controller can be as well changed by using of LiteEdit software via
IL-NT RS232, IL-NT RS232-485 or IL-NT S-USB communication modules.
WARNING:
Disconnect power source from the controller before exchanging the communication module!
6. Connec
iMonitor software or just a web browser with your
WebSupervisor account (http://websupervisor.comap.cz
t the IB-Lite to the router via UTP cable.
7. For connection with controller use LiteEdit or Intel ) or simply embedded SCADA WebServer
with putting of public IP Address (“IBLite IP Addr”) into the address bar.
NOTE:
More detailed information about IB-Lite you can find in IB-Lite Reference Guide available on ComAp website.

Other ComAp Control Unit manuals

ComAp CM2-4G-GPS User manual

ComAp

ComAp CM2-4G-GPS User manual

ComAp IL-NT User manual

ComAp

ComAp IL-NT User manual

ComAp IL-NT-GPRS User manual

ComAp

ComAp IL-NT-GPRS User manual

ComAp UC-7112-LX Plus User manual

ComAp

ComAp UC-7112-LX Plus User manual

Popular Control Unit manuals by other brands

Patching Panda BD-Z user manual

Patching Panda

Patching Panda BD-Z user manual

EUCHNER MCM-MLI Series operating instructions

EUCHNER

EUCHNER MCM-MLI Series operating instructions

Roughneck 27893 owner's manual

Roughneck

Roughneck 27893 owner's manual

Emerson KEYSTONE F580 INSTALLATION AND REPAIR INSTRUCTIONS

Emerson

Emerson KEYSTONE F580 INSTALLATION AND REPAIR INSTRUCTIONS

Crowcon Detective Net User & Operator Manual

Crowcon

Crowcon Detective Net User & Operator Manual

Wolf R1 Installation and operating instructions

Wolf

Wolf R1 Installation and operating instructions

CodeMate 94008 manual

CodeMate

CodeMate 94008 manual

BENDIX SR-7 SPRING BRK MODULATING VALVE Applications

BENDIX

BENDIX SR-7 SPRING BRK MODULATING VALVE Applications

Kracht SPV Operation manual

Kracht

Kracht SPV Operation manual

DEWESOFT Krypton Technical reference manual

DEWESOFT

DEWESOFT Krypton Technical reference manual

Campbell SDM-AO4A product manual

Campbell

Campbell SDM-AO4A product manual

Eagle 1241 installation instructions

Eagle

Eagle 1241 installation instructions

Yealink EXP50 quick start guide

Yealink

Yealink EXP50 quick start guide

Abov A31G22x manual

Abov

Abov A31G22x manual

Pickering 43-182B user manual

Pickering

Pickering 43-182B user manual

TYROLIT Hydrostress WSE1621 operating instructions

TYROLIT Hydrostress

TYROLIT Hydrostress WSE1621 operating instructions

Vertiv LIEBERT RPC2 Command reference guide

Vertiv

Vertiv LIEBERT RPC2 Command reference guide

AXIOMTEK STX88810VEA user manual

AXIOMTEK

AXIOMTEK STX88810VEA user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.