Commodity Axis POLY-REACTOR ViaAqua PR30/30 User manual

P.O. Box 1210, Camarillo, CA 93011-1210 | www.ViaAquaOceanpure.com
WARNING
Buyer/User Assumes All
Responsibility For Safety And
Proper Use Not In Accordance With
The Directions And Safety Labels.

WARNING!
Buyer/user assumes all responsibility for
safety and proper use not in accordance
with the directions and safety labels.
PR 30/30

• Equippedreadytouse
• Variableowwaterpump
• Intakeandoutputtubing(cuttot)
• Lidsecuredwithlatches
ViaAqua®Poly Reactor™ is built with high quality acrylic and an easy to remove lid
with a recessed o-ring. The reverse water ow design eliminates water channeling through
the lter media thus efciently utilizing ltering media. ViaAqua®Poly Reactor™ comes
complete and ready to run with a pump and all plumbing parts. ViaAqua®Poly Reactor™ is
designed to be installed either in-sump or hang on the tank.
IMPORTANT WARNING AND SAFEGUARDS
This product may contain chemicals known to the state of California to
cause cancer and or birth defects or other reproductive harm. Wash
your hand after handling this product.
It is your sole responsibilities to verify that the plug and the receptacle
are clean and free of moisture and salt build up at all times. The
receptacle must be free of water, salt, calcium, magnesium and
dust. Failure to do so can cause fire, damage to property, permanent
damage to the product and personal injury not limited to loss of life.
Do not plug into extension cord/power strip.
A drip loop must be used when plugging all electrical aquarium
devices. A drip loop is that part of the cord hanging below the
receptacle.
The national code requires that a GFCI (Ground fault circuit
interrupter) be used in the branch circuit supplying all power to
water pumps and electrical aquarium equipment. If you do not
have a GFCI, have an electrician install one prior to operating
any aquarium component.
• Read and follow all instructions before using the ViaAqua®Poly Reactor™to ensure
proper use and application.
• Use this product for its intended use only.
• Do not operate ViaAqua®Poly Reactor™ without water. Doing so can cause permanent
damage to the pump.
• Prior to maintenance on any electrical aquarium appliance or aquarium, you must
disconnect all electrical aquarium devices.
• Routine maintenance is required to ensure the maximum performance and the longevity of
the ViaAqua®Poly Reactor™. See maintenance guidelines.
• The use of a surge suppressor is strongly recommended.
ViaAqua® Poly Reactor™ is used for a number of different applications: phosphate resins,
phosphate sponge, activated carbon, nitrate sponge and other resin ltering medias. When the
ViaAqua® Poly Reactor™ is used with activated carbon, a higher ow pump can be used.
PART LIST
1. Reaction chamber
2. Latches
3. Down tube
4. Sediment discharge lter
5. Barbed tting
6. Lock nut
7. Lid
8. O-ring
9. Media sponge
10.Media strainer
11.Hanger
12.Suction cup bracket
13.Control valve
14.Pump
15.Tubing (6ft.)
• RecessedsiliconeO-ring
• Usein-sumporhangontank
• Sedimentdischargelter
• Upowltration
Drip
Loop
GFCI
ONLY

INSTALLATION
1. ChooseadesiredlocationforPolyreactor.
2. Placepumpindesiredlocation.
3. Securethepumpandconnectapieceoftubingfromthepumptothecenter
barbedtting(IN)securethetubingwiththecompressionnut. (NOTE: 6ft.
tubing provided is cut to t for output tubing and intake tube.)
4. Connectdischargetubingtotheoutputofthepolyreactorandsecurethetubing
withcompressionnut.
5. Connectthesedimentdischargeltertotheendoftheoutputtubing.
6. Securetheoutputtubingandsedimentdischargelterwithsuctioncups.
7. Unlatchlidandremovelid
8. Removethetopmediaspongeandmediastrainer.
9. Adddesiredmedia (follow manufactures guidelines for media requirements
for a given aquarium size. ow rate and precautions.)
10.Replacemediaspongeandmediastrainer.
11.VerifytheO-ringiscleanandfreeofallmedia.Asmallamountofsilicone
lubricantcanbeusedtoensureagoodseal.
12.Replacelidpressdirectlydownsothatthedowntubeagainstwith
thebarbedtting(IN).
13.Securewithlatches.
14.PlugpumpintoaGFCIoutlet.
SETUP DIAGRAM
A) HANG ON TANK
MAINTENANCE
1.Routinemaintenanceisrequiredtoensurethemaximumperformanceandthe
longevityoftheViaAqua®waterpump.
2.Forproperoperationofthewaterpump:cleanthepump,impellerandintake
strainerseverythreeweeks.Failuretodosowillcauseprematurefailureof
thepump.
3.BasicmaintenanceoftheViaAqua®pump:
a)Disconnectthewaterpumpfromthepowersupplypriortoremovingthepump
fromtheaquarium.
b)Removeeithertheprelterorintakelterstrainer.Rinseoutprelterspongeof
alldebris.
c)Removetheimpellercover.
d)Oncetheimpellercoverisremoved,slideboththeimpellerandshaftoutof
themainbodyofthepumpandcleanwell.Donotuseanysoapordetergents
duringcleaning.
e)Aftertheimpellerandshaftarecleaned,useasmallbrushtocleaninsideofthe
motorhousing.
f)ReassembleabovepartsandyourViaAqua®pumpisreadytouse.Makesure
thebushingisreassembledproperly.Failuretodosowillcausepermanent
damagetothepump.
Sump
Pump
Intake tube
Output tube
Maximum
10in media
(not included)
Maximum
10in media
(not included)
Pump
Intake tube
Output tube
Aquarium
B) SUMP

LIMITED WARRANTY
CommodityAxis,Inc.® warrantsthattheViaAqua®PolyReactorTM isfree fromdefectsfor a
periodofoneyearfromtheinitialdateofpurchaseshownontheoriginalcashregisterreceipt.
CommodityAxis,Inc.®disclaimallotherwarranties,expressorimplied,includingbutnotlimited
toanyimpliedwarrantiesofmerchantabilityand/ortnessforaparticularpurpose.Although
thislimitedwarrantygivesyouspecicrights,youmayhaveotherrightswhichvaryfromstate
to state. This warranty is void if the failure is due to misuse, tampering, negligence, abuse,
accidentand/orsubmersion,afailuretoproperlyinstall,maintain,clean,prelter,reassemble,
and/or use the ViaAqua®PolyReactorTM with a Ground Fault Circuit Interrupter (GFCI).
CONSUMER REMEDIES
CommodityAxis,Inc.’sentireliabilityandyoursoleandexclusiveremedyshallbeeitherrepair
orreplacementoftheViaAqua®PolyReactorTMonlyifyoureturnthedefectiveunitdirectlyto
CommodityAxis,Inc.®withtheoriginalreceiptinits originalboxalongwithtwentydollars
($20.00)forshippingandhandling.DonotsendtheViaAqua®PolyReactorTMbyinsuredmail.
YoumaysendyourreturnsorreplacementsbyUPSifrequiringasignatureuponarrival.Any
replacedunitwill bewarrantedfor theremaining timeofthe originalwarrantyperiod. Inno
event shall any shipping charges be reimbursed. In no event will CommodityAxis, Inc.® be
liable for any consequential or incidental damages, including but not limited to lost sea life,
personalinjury,propertydamage,equipmentdamage,lostprots,lostwages,lostsavings,lost
income,etc.,arisingoutoftheuseoftheViaAqua®PolyReactorTM.Somestatesdonotallow
forthelimitationorexclusionofliabilityforincidentalorconsequentialdamages,sotheabove
exclusionmaynotapplytoyou.
RETURNS
Pleasecontactourservicecenterat(888)838-3882orfax(888)989-0878toarrangerepair
and/orreplacement.Pleaseallow4-6weeksforallreturns.CommodityAxis,Inc.®cannotship
norrespondtoaP.O.Boxaddress.
WARRANTY CARD
PleasemailwarrantycardandPROOFOFPURCHASEwithin15daysofpurchaseto:
CommodityAxis,Inc.,P.O.Box1210,Camarillo,CA93011-1210.
ModelDateofPurchaseDealerName
FirstandLastNamePhoneNumber
Address,City,State,Zipcode
POLY-REACTORS PR 30/30
Replacement Parts UPC 0069037
WaterpumpVA-4006.2W 30198
O-ringforthelid 30204
Watercontrolvalve 30211
Mediasponges-2pk 30228
Assemble or Use Problems
Ifyouhaveanyproblemsassemblingorusingthisunit
DONOTRETURNViaAqua®PolyReactorTMtothestore.
Technical Service Department
MondaytoFriday9am-5pmPST
(805)383-3566ext.102
e-mail:[email protected]

Commodity Axis, Inc.®is also a manufacture of
ViaAqua®Acro-Cal™ Reactor, ViaAqua®Poly Reactor™,
ViaAqua®Oceanpure™Salt, ViaAqua®Glass Heater, ViaAqua®Titanium Heater,
ViaAqua®MillionAir™Air Pump, ViaAqua®Water Pumps, ViaAqua®Glass Aquariums
and Helios®Lighting Systems.
© 2009 Commodity Axis, Inc.®
Specifications are subject to change without notice
Bringing Products to Life
P.O. Box 1210,
Camarillo, CA 93011-1210
www.CommodityAxis.com
www.ViaAqua.net
www.ViaAquaOceanpure.com
www.OceanpureSalt.com
Table of contents
Other Commodity Axis Aquarium manuals
Popular Aquarium manuals by other brands

Waterbox
Waterbox REEF LX product manual

Waldbeck
Waldbeck 10031075 manual

Red Sea
Red Sea MAX NANO Complete Plug & Play Open Top Reef... Installation and operation manual

AQUAMAXX
AQUAMAXX cTech T Series quick start guide

JBL
JBL SOLAR TROPIC T8 Product information

Ultra Reef
Ultra Reef UCS-140 instruction manual

Reef Factory
Reef Factory Thermo control user manual

Royal Exclusiv
Royal Exclusiv Bubble King DeLuxe 200 VS14 datasheet

Aqua One
Aqua One Glass Heater manual

AquaticLife
AquaticLife 420624 Installation, operation, maintenance guide

Airmax
Airmax Lake Series Installation & maintenance

Aqua Medic
Aqua Medic EVO 3000 Operation manual