manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Comnet
  6. •
  7. Cell Phone
  8. •
  9. Comnet CLTVE1COAX/M User manual

Comnet CLTVE1COAX/M User manual

This manual suits for next models

4

Popular Cell Phone manuals by other brands

Nokia 6700 classic user guide

Nokia

Nokia 6700 classic user guide

LG L34C user guide

LG

LG L34C user guide

Ericsson T60d manual

Ericsson

Ericsson T60d manual

Zte Score M user manual

Zte

Zte Score M user manual

Sony Xperia Z1 Compact Startup guide

Sony

Sony Xperia Z1 Compact Startup guide

AT AT-Q5 user manual

AT

AT AT-Q5 user manual

Vingtor ACM-M-A-V2 Installation/configuration

Vingtor

Vingtor ACM-M-A-V2 Installation/configuration

Olitech EasyFlip 2 Quick setup guide

Olitech

Olitech EasyFlip 2 Quick setup guide

Zte Atrium Z793C user manual

Zte

Zte Atrium Z793C user manual

Alcatel IDEAL manual

Alcatel

Alcatel IDEAL manual

Zte BLADE A520 quick start guide

Zte

Zte BLADE A520 quick start guide

switel M222 user manual

switel

switel M222 user manual

LG LG-P503 user guide

LG

LG LG-P503 user guide

LG F2410 user guide

LG

LG F2410 user guide

Argom E500 manual

Argom

Argom E500 manual

Hisense U30 user manual

Hisense

Hisense U30 user manual

Argom Tech E401 user manual

Argom Tech

Argom Tech E401 user manual

Nokia 3595 - Cell Phone - GSM Manual Del Usuario

Nokia

Nokia 3595 - Cell Phone - GSM Manual Del Usuario

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

INS_CL(T,R)VE(1,2)COAX[POE][M]_REV- 04/25/13 PAGE 1
INSTALLATION AND OPERATION MANUAL
CL(T,R)VE(1,2)COAX[POE][/M]
ANALOG AND IP VIDEO OVER COAX
The ComNet™CL(T,R)VE(1,2)COAX[POE][/M] is a communications link that combines
composite analog baseband video and 10/100T(X) Ethernet on a single RG59 coaxial
cable and transmits it up to 500 meters. The device is particularly suited to applications
where the addition of IP Video to an existing analog video system is required. The
CLTVE1COAXPOE/M model can provide power to the IP device via PoE.
LED indicators are provided for rapidly ascertaining the operating status of the
device. See Figure 6 on Page 5for an explanation of the LED Indicators.
Packaged in a rugged, compact sized housing, these units are designed for surface or
stand-alone mounting, or may be DIN-rail mounted by the addition of ComNet model
DINBKT2 Adaptor plate kit. Refer to Installation Considerations on Page 5 and
Figure A on Page 6for mounting instructions.
See Figures 1 – 6for complete installation instructions.
This manual serves the following
ComNet Model Numbers:
CLT VE1COA X /M
CLRVE1COAX/M
CLTVE1COAXPOE/M
CLRVE1COAX
CLRVE2COAX
INS_CL(T,R)VE(1,2)COAX[POE][M]_REV- 04/25/13 PAGE 2TECH SUPPORT: 1.888.678.9427
INSTALLATION AND OPERATION MANUAL CL(T,R)VE(1,2)COAX[POE][/M]
FIGURE 1 – CLTVE1COAX/M TRANSMITTER
FIGURE 2 – CLRVE1COAX/M RECEIVER
COAX
LINK TO RX
MODULE
COAX
LINK TO TX
MODULE
ETHERNET
ETHERNET
ANALOG
VIDEO IN
ANALOG
VIDEO OUT
Black w/ White
Stripe (AC or DC+)
Black (AC or DC–)
Black w/ White
Stripe (AC or DC+)
Black (AC or DC–)
Operating Power: 12 to 36 VDC or 24 VAC
Power Consumption: 2W
Operating Power: 12 to 36 VDC or 24 VAC
Power Consumption: 2W
INS_CL(T,R)VE(1,2)COAX[POE][M]_REV- 04/25/13 PAGE 3TECH SUPPORT: 1.888.678.9427
INSTALLATION AND OPERATION MANUAL CL(T,R)VE(1,2)COAX[POE][/M]
Black w/ White
Stripe (AC or DC+)
Black (AC or DC–)
FIGURE 3 – CLTVE1COAXPOE/M TRANSMITTER WITH POE
COAX
LINK
TO RX
MODULE
ETHERNET
IEEE 802.3at
PoE (30W Max)
ANALOG
VIDEO IN
Operating Power: 12 to 36 VDC or 24 VAC
Power Consumption: 2W
Note: Power consumption does not include that of Powered Device(s) (PD)
Black (GND)
Black w/ White
Stripe (+Vin)
FIGURE 4 – CLRVE1COAX RECEIVER
ETHERNET
ANALOG
VIDEO OUT
COAX LINK TO
TX MODULE
Operating Power: 9 to 18 VDC
Power Consumption: 2W
INS_CL(T,R)VE(1,2)COAX[POE][M]_REV- 04/25/13 PAGE 4TECH SUPPORT: 1.888.678.9427
INSTALLATION AND OPERATION MANUAL CL(T,R)VE(1,2)COAX[POE][/M]
FIGURE 5 – CLRVE2COAX RECEIVER
CH 1
ETHERNET
CH 2
ETHERNET
CH1 ANALOG
VIDEO OUT
CH1 COAX LINK
TO TX MODULE
CH2 ANALOG
VIDEO OUT
CH2 COAX LINK
TO TX MODULE
Operating Power: 9 to 18 VDC
Power Consumption: 4W
Black (GND)
Black w/ White
Stripe (+Vin)
INS_CL(T,R)VE(1,2)COAX[POE][M]_REV- 04/25/13 PAGE 5TECH SUPPORT: 1.888.678.9427
INSTALLATION AND OPERATION MANUAL CL(T,R)VE(1,2)COAX[POE][/M]
Installation Considerations
This Ethernet unit is supplied as a Standalone/Rack module. Units should be installed in dry locations protected from extremes of
temperature and humidity.
C1-US, C1-EU, C1-AU or C1-CH Card Cage Racks
CAUTION: Although the units are hot-swappable and may be installed without turning power off to the rack, ComNet recommends
that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove
electrical connector before installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge connector at the
back of the card seats in the corresponding slot in the rack’s connector panel. Seating may require thumb pressure on the top
and bottom of the card’s front panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 power supply.
IMPORTANT SAFEGUARDS:
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack
environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation
of the equipment is not compromised.
FIGURE 6 – INDICATING LEDS
ETHERNET LINK
(Yellow/Off)
ETHERNET ACTIVITY
(Solid/Flashing Green)
GREEN YELLOW RED OFF
COAX LINK Coax interface linked N/A Coax Interface Not Linked Unit Powered Down
COAX ACTIVITY Activity detected (flashing or
solid)
N/A N/A No Activity
POE
(CLTVE1COAXPOEM/M)
PoE power is being supplied. N/A N/A PoE is not supplied.
VIDEO DETECT Video signal detected on the
Video BNC
N/A No Video signal detected on
the Video BNC
Unit Is Powered Down.
ETHERNET LINK N/A Interface Linked N/A Interface Not Linked
ETHERNET ACTIVITY Activity Detected N/A N/A No Activity Detected
INS_CL(T,R)VE(1,2)COAX[POE][M]_REV- 04/25/13 PAGE 6TECH SUPPORT: 1.888.678.9427
INSTALLATION AND OPERATION MANUAL CL(T,R)VE(1,2)COAX[POE][/M]
© 2016 Communications Networks Corporation. All Rights Reserved. “ComNet” and the “ComNet Logo” are registered trademarks of Communication Networks, LLC.
3 CORPORATE DRIVE | DANBURY, CT 06810 | USA
T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | [email protected]
8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE
T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | [email protected]
FIGURE A
Dimensions are for a standard ComNet™ one slot module
FIGURE B
Dimensions are for a small size ComNet™ surface mount module
FIGURE C
Dimensions are for a two-high small size ComNet™ surface mount module
.156 [3.96 mm]
.313 [7.95 mm]