Compaq 166207-B21 - Smart Array 5302/32 RAID... User manual

COMPAQ CONFIDENTIAL
Writer: John Turner File Name: a-frnt.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 5/23/02 12:42 PM
Compaq Smart Array 5300 Controller
User Guide
Part Number 135606-004
May 2002 (Fourth Edition)

COMPAQ CONFIDENTIAL
Writer: John Turner File Name: a-frnt.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 5/23/02 12:42 PM
© 2002 Compaq Information Technologies Group, L.P.
Compaq, the Compaq logo, Compaq Insight Manager, ProLiant, ROMPaq, SmartStart,
SoftPaq, and StorageWorks are trademarks of Compaq Information Technologies Group, L.P.
in the U.S. and/or other countries. Microsoft, MS-DOS, Windows, and Windows NT are
trademarks of Microsoft Corporation in the U.S. and/or other countries.
All other product names mentioned herein may be trademarks of their respective companies.
Compaq shall not be liable for technical or editorial errors or omissions contained herein. The
information in this document is provided “as is” without warranty of any kind and is subject to
change without notice. The warranties for Compaq products are set forth in the express limited
warranty statements accompanying such products. Nothing herein should be construed as
constituting an additional warranty.
Compaq Smart Array 5300 Controller User Guide
May 2002 (Fourth Edition)
Part Number 135606-004

Compaq Smart Array 5300 Controller User Guide iii
COMPAQ CONFIDENTIAL
Writer: John Turner File Name: a-frnt.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 5/23/02 12:42 PM
Contents
About This Guide
Important Safety Information ............................................................................................ ix
Symbols on Equipment...................................................................................................... ix
Symbols in Text.................................................................................................................. x
Text Conventions............................................................................................................... xi
Related Documents............................................................................................................ xi
Getting Help...................................................................................................................... xii
Compaq Technical Support........................................................................................ xii
Compaq Website ........................................................................................................ xii
Compaq Authorized Reseller ....................................................................................xiii
Reader’s Comments.........................................................................................................xiii
Chapter 1
Board Components and Features
Overview of Controller Features .....................................................................................1-4
Overview of Array Accelerator Features.........................................................................1-5
Batteries.....................................................................................................................1-6
PCI System Interface .......................................................................................................1-8
SCSI Support ...................................................................................................................1-8
Fault Management Features............................................................................................. 1-8
Chapter 2
Installation Overview
Procedure for a New System ...........................................................................................2-1
Procedure for a Pre-configured System...........................................................................2-2

Contents
iv Compaq Smart Array 5300 Controller User Guide
COMPAQ CONFIDENTIAL
Writer: John Turner File Name: a-frnt.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 5/23/02 12:42 PM
Chapter 3
Installing the Hardware
Preparing the Server........................................................................................................ 3-1
Installing the Smart Array Controller.............................................................................. 3-2
Connecting the Cables..................................................................................................... 3-3
Internal Cabling for Compaq Servers....................................................................... 3-4
External Cabling for Compaq Servers...................................................................... 3-5
Chapter 4
Updating the System Firmware
Running System ROMPaq from the CD......................................................................... 4-1
Running System ROMPaq from Diskette ....................................................................... 4-2
Creating a System ROMPaq Diskette from the CD ................................................. 4-2
Creating a System ROMPaq Diskette from the SoftPaq File ................................... 4-2
Using the Diskette .................................................................................................... 4-3
Chapter 5
Updating the Controller Firmware
Running Options ROMPaq from the CD ........................................................................ 5-2
Running Options ROMPaq from Diskettes..................................................................... 5-3
Creating Diskettes Using the Smart Array Controller Support Software CD .......... 5-3
Creating Diskettes Using the SmartStart CD............................................................ 5-3
Creating Diskettes Using the SoftPaq File ............................................................... 5-4
Using the Diskettes................................................................................................... 5-4
Updating the System Partition ........................................................................................ 5-5
Chapter 6
Setting the Controller Order
Using RBSU.................................................................................................................... 6-1
Using ORCA ................................................................................................................... 6-2
Chapter 7
Configuring an Array
Using ORCA ................................................................................................................... 7-3
Using ACU...................................................................................................................... 7-4
Running ACU from CD............................................................................................ 7-5
Running ACU while Online ..................................................................................... 7-5
ACU Screen Descriptions......................................................................................... 7-5

Contents
Compaq Smart Array 5300 Controller User Guide v
COMPAQ CONFIDENTIAL
Writer: John Turner File Name: a-frnt.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 5/23/02 12:42 PM
Typical Manual Configuration Procedures in ACU................................................7-16
Using CPQONLIN......................................................................................................... 7-26
Running CPQONLIN..............................................................................................7-27
Typical Manual Configuration Procedures in CPQONLIN .................................... 7-30
Chapter 8
Installing the Device Drivers
Using the Smart Array Controller Support Software CD ................................................ 8-1
Using the SmartStart CD ................................................................................................. 8-1
Updating the Compaq Insight Manager Agents ..............................................................8-2
Chapter 9
Upgrading and Replacing Options
Array Accelerator ............................................................................................................9-1
Battery Pack.....................................................................................................................9-4
2- to 4-Channel Adapter Board........................................................................................ 9-8
Enabling RAID ADG ....................................................................................................9-12
Using the Software Key .......................................................................................... 9-12
Using the Enabler Module.......................................................................................9-13
Appendix A
Regulatory Compliance Notices
Regulatory Compliance Identification Numbers ............................................................ A-1
Federal Communications Commission Notice ............................................................... A-1
Class A Equipment................................................................................................... A-2
Class B Equipment................................................................................................... A-2
Declaration of Conformity for Products Marked with the FCC Logo,
United States Only ................................................................................................... A-3
Modifications ........................................................................................................... A-3
Cables....................................................................................................................... A-4
Canadian Notice (Avis Canadien) .................................................................................. A-4
Class A Equipment................................................................................................... A-4
Class B Equipment................................................................................................... A-4
Mouse Compliance Statement ........................................................................................ A-4
European Union Notice .................................................................................................. A-5
Japanese Notice .............................................................................................................. A-6
Taiwanese Notice............................................................................................................ A-6
Battery Replacement Notice ........................................................................................... A-7

Contents
vi Compaq Smart Array 5300 Controller User Guide
COMPAQ CONFIDENTIAL
Writer: John Turner File Name: a-frnt.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 5/23/02 12:42 PM
Appendix B
Electrostatic Discharge
Appendix C
Controller Specifications
Appendix D
Drive Arrays and Fault Tolerance
What Is a Drive Array? ...................................................................................................D-1
Fault-Tolerance Methods ................................................................................................D-5
RAID 0—No Fault Tolerance ..................................................................................D-5
RAID 1+0—Drive Mirroring ...................................................................................D-6
RAID 5—Distributed Data Guarding.......................................................................D-7
RAID ADG—Advanced Data Guarding ..................................................................D-9
Other Fault-Tolerance Options...............................................................................D-11
Appendix E
Hard Drive Installation and Replacement
General Information About Hard Drive Failure.............................................................. E-1
Recognizing Drive Failure........................................................................................ E-2
Compromised Fault Tolerance ................................................................................. E-4
Automatic Data Recovery......................................................................................... E-5
General Aspects of Drive Replacement .......................................................................... E-6
Drive Failure During Rebuild................................................................................... E-7
Moving Drives and Arrays.............................................................................................. E-9
Upgrading Hard Drive Capacity............................................................................. E-10
Expanding and Extending Capacity........................................................................ E-11

Contents
Compaq Smart Array 5300 Controller User Guide vii
COMPAQ CONFIDENTIAL
Writer: John Turner File Name: a-frnt.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 5/23/02 12:42 PM
Appendix F
Probability of Logical Drive Failure
Appendix G
POST Error Messages
Appendix H
Questions and Answers
Glossary
Index

Compaq Smart Array 5300 Controller User Guide ix
COMPAQ CONFIDENTIAL
Writer: John Turner File Name: a-frnt.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 5/23/02 12:42 PM
About This Guide
This guide provides step-by-step instructions for installation, and reference
information for operation, troubleshooting, and future upgrades for the Compaq
Smart Array 5300 Controller.
Important Safety Information
Before installing this product, read the Important Safety Information document
provided.
Symbols on Equipment
The following symbols may be placed on equipment to indicate the presence of
potentially hazardous conditions:
WARNING: This symbol, in conjunction with any of the following symbols,
indicates the presence of a potential hazard. The potential for injury exists if
warnings are not observed. Consult your documentation for specific details.
This symbol indicates the presence of hazardous energy circuits or electric
shock hazards. Refer all servicing to qualified personnel.
WARNING: To reduce the risk of injury from electric shock hazards, do not
open this enclosure. Refer all maintenance, upgrades, and servicing to
qualified personnel.

About This Guide
xCompaq Smart Array 5300 Controller User Guide
COMPAQ CONFIDENTIAL
Writer: John Turner File Name: a-frnt.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 5/23/02 12:42 PM
This symbol indicates the presence of electric shock hazards. The area
contains no user or field serviceable parts. Do not open for any reason.
WARNING: To reduce the risk of injury from electric shock hazards, do not
open this enclosure
This symbol on an RJ-45 receptacle indicates a network interface connection.
WARNING: To reduce the risk of electric shock, fire, or damage to the
equipment, do not plug telephone or telecommunications connectors into this
receptacle.
This symbol indicates the presence of a hot surface or hot component. If this
surface is contacted, the potential for injury exists.
WARNING: To reduce the risk of injury from a hot component, allow the
surface to cool before touching.
These symbols, on power supplies or systems, indicate that the
equipment is supplied by multiple sources of power.
WARNING: To reduce the risk of injury from electric shock,
remove all power cords to completely disconnect power from the
system.
Weight in kg
Weight in lb
This symbol indicates that the component exceeds the recommended
weight for one individual to handle safely.
WARNING: To reduce the risk of personal injury or damage to the
equipment, observe local occupational health and safety requirements
and guidelines for manual material handling.
Symbols in Text
These symbols may be found in the text of this guide. They have the following
meanings.
WARNING: Text set off in this manner indicates that failure to follow directions
in the warning could result in bodily harm or loss of life.

About This Guide
Compaq Smart Array 5300 Controller User Guide xi
COMPAQ CONFIDENTIAL
Writer: John Turner File Name: a-frnt.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 5/23/02 12:42 PM
CAUTION: Text set off in this manner indicates that failure to follow directions could
result in damage to equipment or loss of information.
IMPORTANT: Text set off in this manner presents clarifying information or specific
instructions.
NOTE: Text set off in this manner presents commentary, sidelights, or interesting points of
information.
Text Conventions
This document uses the following conventions:
•Italic type is used for complete titles of published guides or variables. Variables
include information that varies in system output, in command lines, and in
command parameters in text.
•Bold type is used for emphasis, for onscreen interface components (window
titles, menu names and selections, button and icon names, and so on), and for
keyboard keys.
•Monospace typeface is used for command lines, code examples, screen
displays, error messages, and user input.
•Sans serif typeface is used for uniform resource locators (URLs).
Related Documents
For additional information on the topics covered in this guide, refer to the following
documentation:
•Compaq Array Configuration Utility XE User Guide (on the software CD
provided with the server, or downloadable from the Compaq website)
•Compaq Servers Troubleshooting Guide (on the Documentation CD for the
server)

About This Guide
xii Compaq Smart Array 5300 Controller User Guide
COMPAQ CONFIDENTIAL
Writer: John Turner File Name: a-frnt.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 5/23/02 12:42 PM
•Compaq ROM-Based Setup Utility User Guide (on the Documentation CD for
the server, or downloadable from the Compaq website)
Getting Help
If you have a problem and have exhausted the information in this guide, you can get
further information and other help in the following locations.
Compaq Technical Support
In North America, call the Compaq Technical Support Phone Center at
1-800-OK-COMPAQ. This service is available 24 hours a day, 7 days a week. For
continuous quality improvement, calls may be recorded or monitored. Outside North
America, call the nearest Compaq Technical Support Phone Center. Telephone
numbers for worldwide Technical Support Centers are listed on the Compaq website,
www.compaq.com.
Be sure to have the following information available before you call Compaq:
•Technical support registration number (if applicable)
•Product serial number
•Product model name and number
•Applicable error messages
•Add-on boards or hardware
•Third-party hardware or software
•Operating system type and revision level
Compaq Website
The Compaq website has information on this product as well as the latest drivers and
flash ROM images. You can access the Compaq website at www.compaq.com.

About This Guide
Compaq Smart Array 5300 Controller User Guide xiii
COMPAQ CONFIDENTIAL
Writer: John Turner File Name: a-frnt.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 5/23/02 12:42 PM
Compaq Authorized Reseller
For the name of your nearest Compaq authorized reseller:
•In the United States, call 1-800-345-1518.
•In Canada, call 1-800-263-5868.
•Elsewhere, see the Compaq website for locations and telephone numbers.
Reader’s Comments
Compaq welcomes your comments on this guide. Please send your comments and

Compaq Smart Array 5300 Controller User Guide 1-1
COMPAQ CONFIDENTIAL
Writer: John Turner File Name: b-ch1 board components.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 7/22/02 11:09 AM
1
Board Components and Features
The Compaq Smart Array 5300 Series of controllers comprises two models, the 5302
and the 5304. Model 5302 has two Wide Ultra3 SCSI channels and 128 MB of cache;
model 5304 has four Wide Ultra3 SCSI channels and 256 MB of cache. You can
upgrade the 5302 model to have four channels, 256 MB of cache, or both, by means
of the appropriate option kits.
1
2
3
Figure 1-1: Smart Array 5304 Controller
Ite
m
Description
1 Two internal 68-pin Wide SCSI connectors (port 1
nearer the bracket, port 2 nearer the board center)
2 Four external (VHDCI) connectors (ports 1 and 3
nearer the main board)
3 Array accelerator cache

Board Components and Features
1-2 Compaq Smart Array 5300 Controller User Guide
COMPAQ CONFIDENTIAL
Writer: John Turner File Name: b-ch1 board components.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 7/22/02 11:09 AM
NOTE: On both controller models, ports 1 and 2 each have two connectors (one internal and
one external). However, only one connector can be used per port at any given time. Ports 3
and 4 (available on the 5304) can be used only for external drives.
1
2
3
Figure 1-2: Smart Array 5302 Controller
Ite
m
Description
1 Two internal 68-pin Wide SCSI connectors (port 1
nearer the bracket, port 2 nearer the board center)
2 Two external (VHDCI) connectors (port 1 nearer the
board)
3 Array accelerator cache

Board Components and Features
Compaq Smart Array 5300 Controller User Guide 1-3
COMPAQ CONFIDENTIAL
Writer: John Turner File Name: b-ch1 board components.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 7/22/02 11:09 AM
Figure 1-3: Two- to four-channel adapter upgrade
option
Figure 1-4: Array accelerator cache with batteries
For details of the controller board specifications, refer to Appendix C.

Board Components and Features
1-4 Compaq Smart Array 5300 Controller User Guide
COMPAQ CONFIDENTIAL
Writer: John Turner File Name: b-ch1 board components.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 7/22/02 11:09 AM
Overview of Controller Features
•Two or four Wide Ultra3 SCSI channels, supporting up to 56 drives (4 channels,
14 drives per channel)
•Support for Microsoft Windows 2000, Windows NT 4.0, Linux, Novell NetWare
5.x, and NetWare 6 operating systems
•Support for the Compaq Universal Hot Plug Tape Drive, with storage capacity up
to 100 GB and LVD transfer rates up to 12 MB per second
•Support for the Compaq StorageWorksTM SAN Access Module
•Backward compatibility with Wide Ultra2 devices
•Removable array accelerator
•64-bit, 66-MHz PCI system interface
•Other features supported:
—RAID fault-tolerance (0, 1+0, 5, ADG) (refer to Chapter 9 for instructions on
enabling RAID ADG)
—Online RAID migration between any two levels
—Online array capacity expansion
—Online logical drive capacity extension
—Hot-pluggable hard drives and tape drives
—Drive movement
—Adjustable stripe size
—Performance monitoring through Compaq Insight ManagerTM
—S.M.A.R.T. hard drives
—Drive pre-failure notification
—Multiple online spares per array
—Tagged command queuing
—Background initialization
—Multiple logical drives per array

Board Components and Features
Compaq Smart Array 5300 Controller User Guide 1-5
COMPAQ CONFIDENTIAL
Writer: John Turner File Name: b-ch1 board components.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 7/22/02 11:09 AM
Overview of Array Accelerator Features
The array accelerator is a high performance, battery-backed, 100-MHz SDRAM
DIMM cache module.
Array controllers use cache to store read data from the hard drives. The system can
later access this read data. The controller firmware uses the read-ahead and most
recently used caching algorithms.
Array controllers also use cache to complete drive write operations more quickly.
This use of the cache has further performance benefits:
•If the system requires data that still resides in write cache, the controller delivers
this data from the cache. This process is quicker than delivering the data from a
drive.
•If the system writes new data to the same location, the controller overwrites the
cache contents. This eliminates a drive write operation.
•If the system performs a RAID 1 procedure, the controller gets mirrored data
from the cache instead of from host memory.
•If the system performs a RAID 5 procedure, the write cache collects enough data
blocks from several write accesses to carry out a full stripe write to the hard
drives. This operation eliminates the need to calculate and update parity
information each time that a data block is written to the drive.
With a battery-backed cache available, the array controller can complete the
following operations more rapidly:
•Array capacity expansion—the expansion of a logical drive volume to include
more hard drives
•Stripe size migration—the adjustment of the size of data blocks within a stripe,
done to improve performance
•RAID level migration—the adjustment of RAID level to improve the fault
tolerance of the array

Board Components and Features
1-6 Compaq Smart Array 5300 Controller User Guide
COMPAQ CONFIDENTIAL
Writer: John Turner File Name: b-ch1 board components.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 7/22/02 11:09 AM
For each of these operations, data has to be reorganized among hard drives, and must
be saved to non-volatile storage during the operation. (For further details of these
operations, refer to Chapter 7, Appendix D, and Appendix E.) Without battery-
backed cache, the data can only be stored at empty locations within the drive array,
so these operations cannot occur at all if the array is full.
If the array controller or server fails before cached data can be stored on the array, the
array accelerator and its integrated batteries may be removed from one array
controller and installed on another controller of the same type. Any data in the array
accelerator that has not been written to the hard drive will be transferred to the other
array controller.
Other features of the array accelerator include:
•Cache capacity of 96-MB or 224-MB (32 MB of the cache is used for transfer
buffer)
•Adjustable read/write ratio (usually set during array configuration as described in
Chapter 7, but can be changed at any time)
•Error checking and correcting (ECC) memory, providing single-bit data
correction
Sometimes, the Automatic Performance Tuning feature disables the array accelerator.
You can also disable the array accelerator manually through the Array Configuration
Utility (refer to Chapter 7 for details).
Batteries
The array accelerator cache has two rechargeable and replaceable NiMH battery
packs. If the array accelerator is removed from the array controller, the battery packs
maintain any cached data on the array accelerator for up to four continuous days.

Board Components and Features
Compaq Smart Array 5300 Controller User Guide 1-7
COMPAQ CONFIDENTIAL
Writer: John Turner File Name: b-ch1 board components.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 7/22/02 11:09 AM
Figure 1-5: Battery packs
This data protection (and the time limit) also applies if an equipment failure or power
outage occurs. When power is restored to the system, an initialization process writes
the preserved data to the hard drives.
The batteries are continuously recharged using a trickle-charging process whenever
the system power is on. Under normal operating conditions, a battery pack lasts for
three years before replacement is necessary.
IMPORTANT: The batteries on a new array controller may have a low charge when the
controller board is first installed. In this case, a Power-On Self-Test (POST) message 1794 is
displayed when the server is powered up (refer to Appendix G), indicating that the array
accelerator is temporarily disabled. No action is required on your part, since the internal
circuitry automatically recharges the batteries and enables the cache. The recharge process
takes less than four hours. The array controller will function properly during this time, although
without the performance advantage of the array accelerator. When the batteries are charged to
an acceptable capacity, the array accelerator is automatically enabled.
For battery replacement instructions, refer to Chapter 9.

Board Components and Features
1-8 Compaq Smart Array 5300 Controller User Guide
COMPAQ CONFIDENTIAL
Writer: John Turner File Name: b-ch1 board components.doc
Codename: SilverHammer Part Number: 135606-004 Last Saved On: 7/22/02 11:09 AM
PCI System Interface
Smart Array 5300 controllers interface to the server through a high-performance
64-bit PCI bus that:
•Runs at 66 MHz
•Provides a high-speed path (up to 528 MB/s) between the system board and the
controller
•Includes two parity protection signals
The Smart Array 5300 Controller is a PCI Bus Master device conforming to Rev. 2.2
of the PCI Local Bus Specification. As a bus master device, it takes control of the
PCI bus during high-speed transfers, freeing the system processor to handle
application processing or other types of tasks.
For maximum performance, Compaq recommends that you use only 66-MHz devices
on any given 66-MHz PCI bus. Combining 66-MHz and 33-MHz devices on a PCI
bus will decrease the overall bandwidth to 33-MHz speeds.
SCSI Support
The Smart Array 5300 Controller supports drives that conform to Wide Ultra3 and
Wide Ultra2 standards. Although Wide Ultra2 devices operate at a different
maximum speed from Wide Ultra3 devices, operating speeds are unaffected if they
are connected to the same SCSI bus because they both use low voltage differential
(LVD) signaling.
Fault Management Features
The array controller and the network operating system support several fault
management and data reliability features that minimize the impact of hard drive
defects on your system.
Other manuals for 166207-B21 - Smart Array 5302/32 RAID...
3
This manual suits for next models
1
Table of contents
Other Compaq Controllers manuals

Compaq
Compaq 166207-B21 - Smart Array 5302/32 RAID... User manual

Compaq
Compaq StorageWorks HSZ80 User manual

Compaq
Compaq 219700-001 - ProLiant - 1500 User manual

Compaq
Compaq HSG80 Instruction Manual

Compaq
Compaq Smart Array 221 User manual

Compaq
Compaq Storageworks HSJ80 Instruction Manual

Compaq
Compaq Matrox G200 Installation and operating instructions

Compaq
Compaq 226593-B21 - Smart Array 5i RAID Controller User manual

Compaq
Compaq Presario 3200 Series User manual

Compaq
Compaq StorageWorks HSZ80 Parts list manual