By: Comtrol Corp. Rev. 01
iii. The green LED on the Ethernet port will turn on and remain on (on the port the ethernet
cable is connected to. The yellow LED on the ethernet port will flash occasionally. Verify
the behavior of the LEDs on the ethernet ports.
If all LEDs are functioning properly, follow the next steps as described below.
If the Ethernet LEDs are working OK but the Port LEDs are not, discover the unit under test
(UUT) with Comtrol PortVision DX Application and follow the steps described below.
Step 2 –Make sure the UUT and the PC it’s connected to are on the same network
Step 3 –Launch Portvision DX Application and scan the network for “IO-Link Master”units. The
UUT should be discovered and displayed on the Portvision Application as shown below.
oVerify the UUT was discovered
oVerify the Product Model. It should be AY1000 or AY1020
oVerify the MAC Address
oVerify the Status shows ON-LINE
oCheck the IP Address of the discovered UUT
If the UUT wasn’t discovered by Portvision, go to Step 5 below.
Note: Instructions on how to scan the network for “IO-Link Master” unit can be found in the
Comtrol_Portvision_Scan.pdf document which will be provided to see you as a separate
document
Step 4 –If the UUT was discovered, ping the UUT at its IP Address displayed on PVDX. To ping
the UUT, the Subnet Mask of the PC and the UUT have to be compatible. If the subnet masks are