CONCH HM Series Instruction manual

1.
2008.03.24
Connection Manual
CONCH ELECTRONIC CO., LTD.
琦勝企業有限公司
H
H
HM
M
M
S
S
Se
e
er
r
ri
i
ie
e
es
s
s
CONCH ELECTRONIC CO., LTD.
V1.00
Connection and Setting
Explanations


Table of Contents
i
2. Table of Contents
2. Table of Contents...............................................................................i
3. Preface..............................................................................................1
4. Pin Definition of Communication Serial Ports ................................. 3
4.1. COM1 ................................................................................................ 3
5. Make of Download Cable.................................................................. 5
5.1. To Download Application via Serial Ports ............................................ 5
5.2. Direct Download via USB Port ............................................................ 8
6. Instruction of the Wiring & Setting of Supported Communication
Devices ....................................................................................................9
6.1. HM Series Internal Registers..............................................................11
6.1.1. Register Type & Range: ..............................................................11
6.1.2. Contact Type & Range: ...............................................................12
6.1.3. Function Definitions of System Controlling Status Registers: .......13
●System Controlling Area Register: (CB0 ~ CB31; 32 words max.) ................. 13
●System Status Area Register: (SB0 ~ SB31; 32 words max.) ......................... 13
●Screen Change Control Register (SNCR): CB0............................................. 13
●Screen Status Register (SNSR): SB0 ........................................................... 14
●Screen Command Status Register (SCSR): SB1 ............................................ 15
●Control Command Flag Register (CCFR): CB2 ............................................ 16
●Control Command Status Register (CCSR): SB2 .......................................... 17
●Curve Control Register (CUCR): CB3 ......................................................... 18
●Curve Control Status Register (CUSR): SB3 ................................................ 18
●Record Buffer Controlling Register (LCR1 ~ LCR3): CB4 ~ CB6 ................. 19

ii
Table of Contents
●Record Buffer Status Register (LSR1 ~ LSR3): SB4 ~ SB6........................... 21
6.2. Allen Bradley MicroLogix PLC ..........................................................23
6.2.1. Register Type & Range: ..............................................................23
6.2.2. Contact Type & Range: ...............................................................24
6.2.3. Settings of Communication Parameters: (According to Linked
Device) 25
6.2.4. Explanation of Communication Wiring: .......................................26
6.3. Delta DVP PLC .................................................................................29
6.3.1. Register Type & Range: ..............................................................29
6.3.2. Contact Type & Range: ...............................................................29
6.3.3. Settings of Communication Parameters: (According to Linked
Device) 30
6.3.4. Explanation of Communication Wiring: .......................................32
6.4. Facon FBs Series PLC........................................................................35
6.4.1. Register Type & Range: ..............................................................35
6.4.2. Contact Type & Range: ...............................................................35
6.4.3. Settings of Communication Parameters: (According to Linked
Device) 35
6.4.4. Explanation of Communication Wiring: .......................................37
6.5. Fuji FLEX-PC N Series / SPB ............................................................44
6.5.1. Register Type & Range: (Addresses of Hexadecimal Values).........44
6.5.2. Contact Type & Range: (Addresses of Hexadecimal Values)..........45
6.5.3. Settings of Communication Parameters: (According to Linked
Device) 45
6.5.4. Explanation of Communication Wiring: .......................................45
6.6. Koyo DirectNET Host (DL/SU Series) ................................................47
6.6.1. Register Type & Ranger: (Value Addresses of Octal Number System)
47

Table of Contents
iii
6.6.2. Contact Type & Range: (Value Addresses of Octal Number System)
48
6.6.3. Settings of Communication Parameters: (According to Linked
Device) 48
6.6.4. Explanation of Communication Wiring: .......................................50
6.7. Koyo Direct205 Series ( K-Sequence )................................................52
6.7.1. Register Type & Range: (Value Addresses of Octal Number System)
52
6.7.2. Contact Type & Range:(Value Addresses of Octal Number System)
53
6.7.3. Settings of Communication Parameters: (According to Linked
Device) 53
6.7.4. Explanation of Communication Wiring: .......................................53
6.8. LG Master-K 120S / 200S ..................................................................56
6.8.1. Register Type & Range: ..............................................................56
6.8.2. Contact Type & Range: ...............................................................56
6.8.3. Settings of Communication Parameters: (According to Linked
Device) 57
6.8.4. Explanation of Communication Wiring: .......................................58
6.9. LG Master-K CNet.............................................................................61
6.9.1. Register Type & Range: ..............................................................61
6.9.2. Contact Type & Range: ...............................................................61
6.9.3. Settings of Communication Parameters: (According to Linked
Device) 62
6.9.4. Explanation of Communication Wiring: .......................................63
6.10. LiYan LYPLC EX Series ....................................................................66
6.10.1. Register Type & Range: ..............................................................66
6.10.2. Contact Type & Range: ...............................................................66

iv
Table of Contents
6.10.3. Settings of Communication Parameters: (According to Linked
Device) 67
6.10.4. Explanation of Communication Wiring: .......................................68
6.11. Matsushita FP Series..........................................................................70
6.11.1. Register Type & Range: ..............................................................70
6.11.2. Contact Type & Range: ...............................................................70
6.11.3. Settings of Communication Parameters: (According to Linked
Device) 70
6.11.4. Explanation of Communication Wiring: .......................................71
6.12. Mitsubishi FX Series / FX2n Series ....................................................74
6.12.1. Register Type & Range: ..............................................................74
6.12.2. Contact Type & Range: ...............................................................74
6.12.3. Settings of Communication Parameters: (According to Linked
Device) 75
6.12.4. Explanation of Communication Wiring: .......................................76
6.13. Mitsubishi FX / FX2n Computer Link .................................................78
6.13.1. Register Type & Range: ..............................................................78
6.13.2. Contact Type & Range: ...............................................................78
6.13.3. Settings of Communication Parameters: (According to Linked
Device) 79
6.13.4. Explanation of Communication Wiring: .......................................80
6.14. Mitsubishi FX3U Series .....................................................................84
6.14.1. Register Type & Range: ..............................................................84
6.14.2. Contact Type & Range: ...............................................................84
6.14.3. Settings of Communication Parameters: (According to Linked
Device) 85
6.14.4. Explanation of Communication Wiring: .......................................86
6.15. Mitsubishi FX3U Series Computer Link..............................................87

Table of Contents
v
6.15.1. Register Type & Range: ..............................................................87
6.15.2. Contact Type & Range: ...............................................................87
6.15.3. Settings of Communication Parameters: (According to Linked
Device) 88
6.15.4. Explanation of Communication Wiring: .......................................89
6.16. Mitsubishi A Series A1SH CPU ..........................................................93
6.16.1. Register Type & Range: ..............................................................93
6.16.2. Contact Type & Range: ...............................................................94
6.16.3. Settings of Communication Parameters: (According to Linked
Device) 95
6.16.4. Explanation of Communication Wiring: .......................................96
6.17. Mitsubishi A Series Computer Link ....................................................97
6.17.1. Register Type & Range: ..............................................................97
6.17.2. Contact Type & Range: ...............................................................98
6.17.3. Settings of Communication Parameters: (According to Linked
Device) 99
6.17.4. Explanation of Communication Wiring: .....................................100
6.18. Modbus Slave ..................................................................................103
6.18.1. Register Type & Range: ............................................................103
6.18.2. Contact Type & Range: .............................................................103
6.18.3. Settings of Communication Parameters: (According to Linked
Device) 103
6.18.4. Explanation of Communication Wiring: .....................................103
6.19. Modbus Slave (Hexadecimal Address) ..............................................108
6.19.1. Register Type & Range: (Addresses of Hexadecimal Values).......108
6.19.2. Contact Type & Range:(Addresses of Hexadecimal Values).........108
6.19.3. Settings of Communication Parameters: (According to Linked
Device) 108

vi
Table of Contents
6.19.4. Explanation of Communication Wiring: .....................................109
6.20. Modbus Master for HM Series ..........................................................113
6.20.1. Register Type & Range: ............................................................113
6.20.2. Contact Type & Range: .............................................................113
6.20.3. Correspondence between HMI Register and Modbus Address: .....114
6.20.4. Correspondence between Addresses of HMI Contacts and Modbus:
114
6.20.5. Settings of Communication Parameters: (According to Linked
Device) 115
6.20.6. Explanation of Communication Wiring: .....................................115
6.21. Omron C Series ( CPM1A / TPM1A )................................................119
6.21.1. Register Type & Range: ............................................................119
6.21.2. Contact Type & Range: .............................................................119
6.21.3. Settings of Communication Parameters: (According to Linked
Device) 120
6.21.4. Explanation of Communication Wiring: .....................................121
6.22. Omron CS/CJ Series (including CP1 Series)......................................123
6.22.1. Register Type & Range: ............................................................123
6.22.2. Contact Type & Range: .............................................................124
6.22.3. Settings of Communication Parameters: (According to Linked
Device) 124
6.22.4. Explanation of Communication Wiring: .....................................125
6.23. Siemens S7-200 PPI.........................................................................127
6.23.1. Register Type & Range: ............................................................127
6.23.2. Contact Type & Range: .............................................................128
6.23.3. Settings of Communication Parameters: (According to Linked
Device) 128
6.23.4. Explanation of Communication Wiring: .....................................129

Table of Contents
vii
6.24. Vigor M/VB/VH Series PLC.............................................................132
6.24.1. Register Type & Range: ............................................................132
6.24.2. Contact Type & Range: .............................................................133
6.24.3. Settings of Communication Parameters: (According to Linked
Device) 133
6.24.4. Explanation of Communication Wiring: .....................................134
7. Revising History ........................................................................... 139


Preface
1
HM Series Connection Manual
3. Preface
Thank you for using this product. This manual will provide the instruction of
communication between HM series Human-machine Interface (HMI) and linked
devices. “Register & Contact Numbering Range”listed in this document is just the
maximum value that the software allows. Please don’t exceed the limitation of the
linked devices themselves in practice; otherwise, it might cause communication
failure. Please read this handbook carefully before you use the product to ensure
the correctness and safety in use. Besides, put the handbook at a noticeable location
so as to make reference more convenient. Before reading through this manual,
please be sure to follow the proceedings as below:
1. Please wire according to the wiring diagram.
2. Grounding must be done for sure.
3. Please do NOT dismount HMI or make any change to the wiring when HMI is
electrified.
4. Please do NOT touch the power terminal when HMI is electrified and operating
to avoid electric shock.
If you still have question when using the product, please contact our sales staff.
Because the “Numbering Range of Registers and Contacts”might change when
PLC manufacturers launch new models, the contents of this manual need modifying
from time to time. Besides, it is difficult to update the information listed in this
handbook with the increase of communication modules. If you need the up-to-date
documents, please contact our staff or download from our Web site
(http://www.conch.com.tw).


4 Pin Definition of Communication Serial Ports
3
HM Series Connection Manual
4. Pin Definition of Communication
Serial Ports
The standard outfit of this product series has 3 serial communication pots, provided
with 3 types of communication interface: RS232/RS485/RS422, which make it
convenient to link different devices. Besides, the 3 ports can be enabled for
communication at the same time to lower the burden of PLC and improve the
system communication performance as a whole.
4.1. COM1
The pin definition of COM1 can support communication formats of RS232 &
RS485.
P6P1
9P
(Female
Adapter)
Pin
Function
1
RS485+
2
RS232 RXD
3
RS232 TXD
4
N/A
5
Signal Ground
6
RS485-
7
RS232 RTS
8
RS232 CTS
9
+5V Output ( Max. 100mA )

4
4.1 COM1
HM Series Connection Manual
COM2 (COM3)
The communication port COM2 supports 3 communication types: RS232 / RS485 /
RS422. COM3 could be enabled if RTS/CTS Handshaking is not employed.
P1 P14
25P
(Female
Adapter)
Pin
COM2 Pin Definition
COM3 Pin Definition*
1
N/A
2
RS232 TXD
3
RS232 RXD
4
RS232 RTS
RS232 TXD
5
RS232 CTS
RS232 RXD
6
+5V Output ( Max. 100mA )
+5V Output ( Max. 100mA )
7
Signal Ground
Signal Ground
8
Alarm Output (Optional)
Contact Specifications-
1A 120VAC / 24VDC
Alarm-C
C
A
B
9
Alarm-A
10
Alarm-B
11
Terminating resistor for CTS-
Terminating resistor for RX-
12
RS422 CTS+
RS422 RX+
13
RS422 CTS-
RS422 RX-
14
RS422 TX+ / RS485+
15
RS422 TX- / RS485-
16
RS422 RX+
17
RS422 RX-
18
Terminating resistor for RX-
19
Signal Ground
Signal Ground
20
N/A
21
N/A
22
N/A
23
RS422 RTS+
RS422 TX+ / RS485+
24
RS422 RTS-
RS422 TX- / RS485-
25
N/A
*Note: COM3 will be enabled only when RTS/CTS handshaking of COM2 is set
Disable.

5 Make of Download Cable
5
HM Series Connection Manual
5. Make of Download Cable
5.1. To Download Application via Serial
Ports
To download application, this mode must be under system utility; otherwise, the
editing software will show “Communication Error”. Each of the communication
port of HMI can be used. Please see the following wiring diagram for reference:
COM1 ( RS232 )
HM Series Terminal
PC Terminal
9Pin D-SUB Male
9Pin D-SUB Female
P1P6
9P
(Male Adapter)
P6P1
9P
(Female
Adapter)
FG FG
3
2
5
RXD
TXD
GND
2
3
5
TXD
RXD
GND

6
5.1 To Download Application via Serial Ports
HM Series Connection Manual
COM2 ( RS232 )
HM Series Terminal
PC Terminal
25Pin D-SUB Male
9Pin D-SUB Female
P14 P1
25P
(Male Adapter)
P6P1
9P
(Female
Adapter)
3
2
5
RXD
TXD
GND
3
2
7
TXD
RXD
GND
FG FG

5 Make of Download Cable
7
HM Series Connection Manual
COM3 ( RS232 )
HM Series Terminal
PC Terminal
25Pin D-SUB Male
9Pin D-SUB Female
P14 P1
25P
(Male Adapter)
P6P1
9P
(Female
Adapter)
3
2
5
RXD
TXD
GND
5
4
19
TXD
RXD
GND
FG FG

8
5.2 Direct Download via USB Port
HM Series Connection Manual
5.2. Direct Download via USB Port
If the download of application is through the USB port, it is not limited to be under
System Utility. Download can be operated even if the application is running.
Transfer cable is standard USB cable. See the below for your reference:
USB Device
HM Series Device Terminal
PC Host Terminal
USB Type B Plug
USB Type A Plug
Pin out of the USB Type A/B Connector
Pin
Name
Cable color
Description
1
VCC
Red
+5V DC
2
D-
White
Data-
3
D+
Green
Data+
4
GND
Black
Ground

6 Instruction of the Wiring & Setting of Supported Communication Devices
9
HM Series Connection Manual
6. Instruction of the Wiring & Setting of
Supported Communication Devices
The “Numbering Range of Registers and Contacts”may change when PLC
manufacturers release new models from time to time, which makes the contents of
this handbook would need revising all the time. Moreover, communication modules
are increasing all the time; as a result, there is difficulty updating the information
listed in this handbook. If the latest version is needed, please contact the sales staff,
or visit our Web site: http://www.conch.com.tw to download it.
Compatible brands and models are listed in the following table:
Brand
Model & Type
Conch
HM Series Internal Registers
Allen Bradley
MicroLogix PLC
Delta
DVP PLC
Facon
FBs Series PLC
Fuji
FLEX-PC N Series / SPB
Koyo
DirectNET Host ( Direct DL / SU Series )
Direct205 Series ( K-Sequence )
LG
Master-K 120S / 200S
Master-K CNet
LiYan
LYPLC EX Series
Matsushita
FP Series
Mitsubishi
FX Series
FX2n Series
FX / FX2n Computer Link ( Format1 / Format4 )
FX3U Series

10
6 Instruction of the Wiring & Setting of Supported Communication Devices
HM Series Connection Manual
Brand
Model & Type
FX3U Computer Link ( Format1 / Format4 )
A Series A1SH CPU
A Series Computer Link ( Format1 ~ Format4 )
Modbus
Modbus Slave ASCII Mode
Modbus Slave RTU Mode
Modbus Slave ASCII Mode ( Hexadecimal Address )
Modbus Slave RTU Mode ( Hexadecimal Address )
Modbus Master ASCII Mode for HM Series
Modbus Master RTU Mode for HM Series
Omron
C Series ( CPM1A / TPM1A )
CS/CJ Series ( including CP1 Series )
Siemens
S7-200 PPI
Vigor
M / VB / VH Series PLC
Table of contents