Conlan 460116 User manual

secure open
Conlan ApS • Speditorvej 2A • DK-9000 Aalborg • Tel: +45 72 40 60 03 • Fax: +45 96 32 00 22
www.conlan.eu • [email protected]
Wiegand
Controller
Art. No.: 460116
User manual
Wiegand_usermanual_ENGjun15

2
Two way - One door controller
Specikations:
• Controller for one door, 2 readers
• Space for 511 user codes/tags + 1 Master code/tag
• 3584o-lineeventswithdateandtimestamp
• Real time clock
• Backup battery for clock, EEProm memory
• Dual-processor
• Fully stand alone or networkable
• Possibillityforstandaloneadd/deletecodes/tagsincludinglostordamagedtagswithoutneedtodeleteall
users or connect to a PC
• PCconnectionviaRS485orRS232
• Network connection or direct connection to RS232 serial port
• Lockingdevicerelay,NO/NCselectablebyJumper/software
• Alarmrelay,NO/NCselectablebyJumper/software
• Door contact input (NC)
• Request to exit button (REX) (NC)
• Inputs for two 26 bit Wiegand readers (In and Out)
• Open collector outputs for reader LED and buzzer
• Stand alone reset using wire
• Tamperswitch(NC)
• 12 Vcc, 500 mA max. power input.
Connections
!!! Caution-readalltheinstructionsinordertoassureaproperworkingofthecontroller
12V; GND Power supply, 12 Vcc, 500 mA max.
T;T Tamperswitch(NC)
GND Ground
x-; x+ RS485 port
LK;LK Lockingdevicerelay
AL; AL Alarm relay
BUZ Open collector output for buzzer
LED Open collector output for LED
COM Common door contact and REX
CM Door contact input
REX Request to exit input (REX)
D0; D1 Data from readers
Power supply
12 V / 500 mA
CM REX
W26CTRL COM CM REX D0 D1 D0 D1LEDBUZ
GND12VTTGNDX-X+LKLKALAL
J1 J2
J3
485 232
Entry Exit
Exit
reader
Entry
reader

Note:
1. Incasethatyouareusingjustonereaderlettheotherinputsunconnected
2. Incasethatyouarenotusingdoorcontactinput,shortcircuitwithawirebetweenCOMandCM.Bydefault
door contact input is NC.
Jumper conguration:
J1 - Alarm relay NO or NC J2-LockingdevicerelayNOorNC J3 - Communication port , RS232 or RS485
Programming:
Bydefault,thefollowingparametersareset:
• Mastercodedened(4711)
• Nousercodes/tagsdened
• Door unlock time = 5 seconds
• Door open time = 30 seconds
• Alarm time = 5 seconds
• Invalidcode/tagstatustime=2seconds
• Re-lockdoor-active
• Re-lockonopening-active
• Door contact type - NC
• REX type NC
Parameters description:
• Door unlock timeisthemaximumactivationtimeforthelockingdevicerelayincaseofavalidcode/tagor
REXactivation.Denedinsecondsfrom1to255.
• Door open timeisthemaximumallowedtimeforthedoortobeleftopen.Thistimestartfromthemoment
ofunlockingthedoor,that’swhythemandatoryistobehigherthenthedoorunlocktime.Ifattheendof
thedoorunlocktimethedoorisstillopen,and“Doorstillopen”eventisgeneratedandloggedandalarm
relayisactivated.Ifyouwanttoletthedoortobeopenedforinnitetime,youshouldsetthistimeatdoor
opentimeto255.Denedinsecondsfrom1to255.
• Alarm Timeisthetimeforalarmrelayactivation.Itstartsfromthemomentofalarmgenerationandend
ofalarmcondition.Ifthedoorisforcedopenwhenalarmrelaywillbestillactiveforalarmtimeafterclosing
thedoor.Sameifthedoorisleftopen.
• Invalid code/card status timeisthetimeforthereaderstoshowtheinvalidstatusofacode/tagusing
LED’sandbuzzer
• Re-lock door-ifactivethedoorisre-lockedwhenitisclosedoropened,dependingofthefollowingsetting
• Relock on opening-isvalidonlyiftheprevioussettingisactive.Ifactivated,thedoorisre-lockedwhenthe
doorisopened,otherwisewhenitisclosing,withoutwaitingfordoorunlocktimetoexpire.
Codes/tags programming:
Forcodes/tagsprogrammingaMastercode/tagisneeded.Thiscanbekeyed/enrolledeitherbystandalonere-
setorbyaPC.Controllermemoryistableconstructed,from0upto511,where0isMasterposition.Werecom-
mendtokeepatableinthefollowingformattobeabletomadeacompletecode/tagprogramming.
Position Code/tag number User name
0 xx:xxxxx Mastercode/tag(4711-default)
1 xx:xxxxx User name 1
2 xx:xxxxx User name 2
... ... ...
511 xx:xxxxx User name 511
Withsystempowered,keyin/presentMastercode/tag.Thesystemgoesintostandaloneprogramming.Pro-
grammingphasesareindicatedbyLEDclippingandbuzzersounds,followedbyapprox.1secondpause.Each
keying/presentationofMastercode/tagputsthesysteminthenextprogrammingphase.
1. Oneshortactivation-keyin/enrollcode/tagintherstfreeposition
2. Twoshortactivations-deleteanexistingcode/tag
3. 3Threeshortactivations-deletealostordamagedtag
3

!!! ATTENTION - It is very important to know each code/tag position.
Program code/tag in the rst free position.
Withsystemon“Programcode/tagintherstfreeposition”keyin/presentthecode/tagyouwanttokeyin/en-
roll.Thiswillbestoredintherstfreepositioninthetable(writedowntheposition).Ifsomeerroroccurswhile
keying/enrolling,thesystemwillsignalwith“invalidcode/tag”,meaningthatthecode/tagisalreadystoredorthe
memory is full.
Afterprogrammingacode/tag,othercodes/tagscanbeprogrammeddirectly.
Delete an existing code/card.
Withthesystemon“Deleteanexistingcode/tag”keyin/presentthecode/tagyouwanttodelete.Thatcode/tag
willbedeletedfromthememoryandthatpositionbecomesfree.Writedownthatpositionasfreepsition.Ifde-
letioncannotbemadean“invalidcode/tag”signalwillbeshownonthereaders,meaningthatthecode/tagdid
notexistinthedatabase.Afterdeletingacode/tag,otherscanbekeyed/presentedtobedeleteddirectly.
Delete a lost/damaged tag.
Withthisoptionyoucandeleteatagwithouthavingthattag.Itisveryusefulincaseoflost/stolen/damaged
tags.Itispossibletodeleteatagwithoutdeletingallcodes/tagsandwithoutusingaPC-fullystandalone.In
thisphaseitisveryimportanttoknowtheuserpositionsinthedatabase.
Withthesystemon”Deletealost/damagedtag”presentthetaginthepositionlowerthanthecardwewnatto
delete.Forinstance,ifwewanttodeletetaginposition37wewillpresentthetaginposition36.Ifwedonthave
ataginposition36(36isfree)wewillpresentthetaginposition35andsoon.Inohterwords,thisphasecanbe
“Deletersttagenrolledafter(asposition)presentedtag”.
Again,itisveryimportanttonoteallpositionsoftagsenrolledordeleted.
Stand alone reset and Master code/tag programming.
TheMastercode/tagcanbeprogrammedinthefollowingsteps:
1. Powero
2. DisconnecttheCMinput
3. ShortcircuitawirebetweenLEDoutputandCMinput
4. Power on
5. Waitapprox.3secondsofLEDashing,thesystemgoesinto“Programcode/tag”phase,asshownbyLED/
buzzer
6. Keyin/presentthecode/tagthatyouwanttobecomeMastercode/tag
7. Atexitofprogramminguserphasepowerothesystem
8. RemovethewirebetweenCMandLED
9. ReconnecttheCMwirefromthemagneticcontact
10. Power on
Forsecurityreasons,alluserswillbedeletedbeforekeying/enrollingMastercode/tag.Thesystemgoesin“Pro-
gramcode/tag”andsinceallusersaredeleted,therstcode/tagprogrammedinposition0becomesMaster
code/tag.
ThankyouforchoosingConlan’sproducts.