ATLO ATLO-FR-601 User manual

Facial Recognition Access Control
User Manual
With fingerprint Without fingerprint

1.Introduction
3.Technical Specifications
12
Operating Current: ≤300mA
Operating Voltage: DC12V
Operating Humidity: 0~95%
Standby Current: ≤180mA
Operating Temperature: -40~60℃
Access mode: Fingerprint, card, facial recognition or
multiple combination
2.Features
Feature Specification
Card Type
Keypad Characteristic
Output Protocol
Access Mode
Admin Card
User Capacity
Facial Recognition
Distance
125KHz EM card(Optional)
13.56MHz Mifare card (Optional)
Infrared remote controller operation.
Can operate as a reader. The transmission format could be adjusted by users.
card, facial recognition , fingerprint, card + fingerprint,
card + facial recognition
admin card, admin fingerprint (add/delete)
10,000 card users,1000 facial users and 600 fingerprint users
50cm-1m
5.Wiring
No. Color Marks Description
1Green
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
D0
D1
ALARM
OPEN
D_IN
+12V
GND
NO
COM
NC
2
3
4
5
6
7
8
9
10
Wiegand input (only when used as a reader)
Wiegand input (only when used as a reader)
Alarm signal MOS tube drain output end (optional)
Exit button input end
Door contact switch input end
Positive power supply or AC power supply end
Negative power supply end
Relay NO
Relay COM
Relay NC
4.Installation
Remove the back cover from the keypad using the supplied special screw driver
Drill 2 holes on the wall for the self-tapping screws and I hole for the cable
Put the supplied rubber bungs to into the two holes
Fix the back cover firmly on the wall with 2 self tapping screws
Thread the cable through the cable hole
Attach the keypad to the back cover. (See the figure below)
The product is a new generation of multi-function facial recognition Standalone Access Controller
and Reader, which utilizes the new powerful, stable and reliable ARM core 32-bit microprocessor
design. It can be used as a Weigand reader, or as a Standalone Access Controller/Reader. And
is suitable for access control applications in offices, residential communities, villa, banks and
prisons.
remote area

Electric control lock
D0
D1
OPEN
D_IN
COM
GND
NC
+12V
NO
ALARM
Green
Green
White
White
Yellow Yellow
Orange
Orange
Red
Red
Blue
Blue
Exit button Exit button
Door contact Door contact
Alarm Alarm
Magnetic lock
Magnetic lock
3
6.Diagram
4
6.1 Common Power Supply
6.2 Special Power Supply
Note: The door contact and alarm function are optional Note: The door contact and alarm function are optional
Brown Brown
Purple Purple
Black Black
Grey Grey
Special power supply

5 6
6.3 Reader Mode 7.Sound and Light Indication
Light indicatorOperation Status Buzzer
Beep—
Beep-Beep-Beep
Beep—
Beep
Beep—
Beep—
Beep—
Beep—
Beep—
Alarm
Red indicator flash slowly
Red
Green
Red indicator flash slowly
Red indicator flash slowly
Red indicator flash slowly
Orange
Green
Red indicator flash quickly
Stand by
Operation successful
Operation failed
Read card under card+facial mode
Read multi user cards
Enter programming mode
Enter setting status
Unlocking
Buzzer alarm
Read card under card+fingerprint mode
Press * key
Press digital key
Admin card exit programming
Admin card enter programming
8.Admin Menu
8.1 Standalone Mode Settings
Device Management
Green
White
Yellow
Orange
Red
Blue Access controller
Brown
Purple
Black
Grey
Function Operation steps Notes
Change Admin Code
Set Admin Add card or fingerprint
Set Admin delete card or fingerprint
Delete Admin Add card or fingerprint
Delete Admin Delete card or fingerprint
Exit Programming
Delete Admin Delete
card or fingerprint
Delete Admin Add card
or fingerprint
Press * to exit
programming
To set Admin Delete
card or fingerprint
To set Admin Add card
or fingerprint
Factory Default Admin
code is 999999. This is
the code when you reset
the device to factory
default
#
*00 New codeAdmin code
# #Repeat New code
#
*
*
02 Read cardAdmin code
# #
*01
Admin code
# #
*
*
02
Admin code
or Fingerprint 3 times
#
*
*
01 Read cardAdmin code
or Fingerprint 3 times

78
Common Operation
Function Operation steps Notes
Function Operation steps Notes
Change Admin code
Add card user
Add fingerprint user
Delete card user
Add face user
Delete face user
Delete fingerprint user
Delete all users
Default Admin code is
999999.
Delete all card users, faces
and fingerprints
Delete multiple fingerprint
users
Delete multiple face users
Delete card user
Each user should present
the same fingerprint 3 times.
Add multiple fingerprint user.
8 faces per user
Add multiple card users
#
*11 Read cardAdmin code
# #...
*21 Read cardAdmin code
# #
*21 ID number
ID number
Admin code
# #
*23 Fingerprint onceAdmin code
# #
*24
Admin code
0000# #
*20
Admin code
#
#
*12
Facial recognition 8 times ...
#
...
#
...
Admin code
# #
*22 Face once ...Admin code
# #
*21 Read cardAdmin code
#
#
*14
Admin code
# #
*20 0000
Admin code
#
*00 New codeAdmin code #
#
Repeat New code
...
#
*21
Admin code
#8 digits or 10 digits card number
ID number #
#
*14
Admin code
#Card+ Facial recognition 8 times
Card+ Facial recognition 8 times
ID number #
#
*15
Admin code
#Card +Fingerprint 3 times
#
Card +Fingerprint 3 times
ID number #
#
*16
Admin code
#Consecutive card, Fingerprint, Face
ID number #
#
*13
Admin code
#Fingerprint 3 times
#
*13 Fingerprint 3timesAdmin code
#
...
#
*23 Fingerprint onceAdmin code
#
#
*22 Facial recognition once Admin code
Delete Users
#
*15
Admin code
Delete card user
Delete ID numbe
Delete face
Delete fingerprint
Delete all users
Delete multiple users
Delete card number
Add multiple fingerprint user by
specifying ID number
Entry by Card +
Facial recognition
Entry by card + fingerprint
Entry by specify user ID number,
then reading card and scanning
face
Entry by specify user ID number,
then reading card and inputting
fingerprint
User ID:1-50,2-10 users
Delete all user cards, faces
and fingerprints
Delete card/fingerprint/face
user by specify ID number
Delete card user by card number
Delete fingerprint user
Delete face user
Delete card user
Delete multiple users by ID number
Add User ID number +
fingerprint
Add User with combined
access mode
Add User with multiple
combined access mode
Function Operation steps Notes
# #...
...
...
*11 Read cardAdmin code
#
*11 ID number Admin code #
#
*11 ID number Admin code #
ID number #
#Read card
#
*11
Admin code
#8 digits or 10 digits card number
#
8 digits or 10 digits card number
#
*12
Admin code
#Facial recognition 8 times
...
#
*13
Admin code
#
Fingerprint 3 times
#
*12
Admin code
#
Facial recognition 8 times
Add Users
Add card user Add multiple card users
Add card user by inputting ID
number and reading card
Add card user by specifying
User ID number and input
card number
Add multiple face user by
specifying User ID number
Add multiple fingerprint user
Add multiple face user.
Device will take 8 pictures
per user
Add card user by inputting card
number. User ID number will be
generated automatically(1~9999)
Add using card number
Add User ID number
+ card
Add User ID number +
facial recognition
Add fingerprint user
Add User ID number +
card number
Add facial recognition user

9.Admin Card Operation
9.1 Add Card
10.User Operation
10.1 Acknowledging the Alarm
9.2 Delete Card
10.2 Reset to Factory Default
Note:
The Admin Delete card is used to delete card users continuously and quickly. When you
present the Admin Delete card,you will hear short "BEEP" sounds twice and the indicator light
turns orange. You have entered into Delete user programming mode.You can now present the
cards for deletion.When it is completed, you can present the Admin Delete card and you will
hear a long "BEEP" sound once and the indicator light turns red,indicating that you have exited
the Delete card user programming mode.
Note:
When the alarm is activated, users can acknowledge and stop the alarm by reading valid
user or Inputting valid fingerprint or pressing admin code.
Note:
Note: Registered user data won’t be deleted when reset to factory default.
Users can reset to device to its factory default if the Admin code is forgotten or the user wants
to place the device back to factory original settings.
Power off the device. Hold down the Exit button. Power on. Release the Exit button only when
you hear the beep sound twice. The Admin code has been reset to 999999, factory and the
device has defaulted to factory setting
To reset, follow the procedures below:
Function Operation steps Notes
Function Operation steps Notes
Read admin delete card Read the 1
st
user card Read the 2
nd
user card Read admin delete card
…
Read admin card Read valid user card Input valid fingerprint Press Admin code
Note:
The Admin Add card is used to add card users continuously and quickly. When you
present the Admin Add card. you will hear short "BEEP" sounds twice and the indicator light
turns orange. You have entered into Add user programming mode.You can present the cards for
programming now.After all the cards are added, present the Admin Add card again.You will hear
long "BEEP" sound once and the indicator light turns red, indicating that you have exited the Add
card user programming mode.
Read admin add card Read the 1
st
user card Read the 2
nd
user card Read admin add card
…
910
# #
*3 0
Admin code
# #
#
*60
Admin code
# #
*6 1
Admin code
# #
*6 2
Admin code
# #
*8 0
Admin code
# #
*81
Admin code
# #
*82
Admin code
# #
*8 3
Admin code
# #
*70
Admin code
# #
*7 1
Admin code
# #
*7 2
Admin code
#
#
*40-300
Admin code
#
#
*50-99
Admin code
# #
*31
Admin code
# #
*32
Admin code
# #
*3 3
Admin code
# #
*3 4
Admin code
# #
*35
Admin code
# #
*36
Admin code
Door unlock time
Door opening time range: 0-300S
0 equals to 50mS, factory default value
is 5S
Alarm time range: 0-99 min. Alarm time
set at 0 means no alarm. Factory default
value is 0
To put the device back to its default factory
operation mode
If enabled, the door will be kept open until
the exit button is pressed. To disable,
return the device back to standalone
access mode as above.
WG26 Output
Without alarm & locked function
Indicator light is on under standby
Indicator light is off under standby
Sound activated during the operation
No sound during the operation
The device will alarm if invalid cards or
codes were presented 10 times continuously
The device will be locked for 10 minutes if
invalid cards or codes are presented 10
times continuously
Alarm time
Reader mode
Locked mode
Alarm mode
Enable light indicator
Disable light indicator
Enable buzzer
Disable buzzer
Normal mode
Relay toggle mode
Standalone access
control mode
Card or facial
recognition or
fingerprint
Entry by card, fingerprint or
facial recognition(default value)
Multiple users
Fingerprint
Facial recognition
Card Entry by card only
Entry by fingerprint only
Entry by multiple cards/mutiple
faces/multiple fingerprints
Entry by card + fingerprint
Entry by Card +
Facial recognition
Entry by facial recognition only
Card + Fingerprint
Card +
Facial recognition
Access ways
Advanced Settings
or or or
Table of contents